| Payment Terms | T/T,Western Union |
| Supply Ability | 100 sets per month |
| Delivery Time | 25-35 working days After receiving deposit |
| Packaging Details | Plywood Case+Foam |
| Product Name | Purification Glove Box |
| Model No. | GBP1000D-4 (1200) |
| Water Content | Less than 1PPM |
| Oxygen | '-3000pa~+3000pa |
| Leakage Rate | Less than 0.05 Vol %/h |
| Bearing Pressure | '-3000pa~+3000pa |
| Operating Side | Double Sided |
| Purification Column | Single or double at buyer's option |
| Brand Name | TENCAN |
| Model Number | GBP1000D-4 (1200) |
| Certification | CE ISO |
| Place of Origin | Hunan, China |
View Detail Information
Explore similar products
China Tencan Glove Box With Purification System GBP750S-3 for Water and Oxygen
TENCAN GBP750S-4(2400) Laboratory Glovebox Inert Gas Glove Box Integrated/Split
TENCAN Lab Purified Glove box GBP1000D-4 (1200) Two-sided Working Glove Box Gas
Laboratory Use GBP750S-4(1800) Inert Gas Glovebox Regeneration System With 4
Product Specification
| Payment Terms | T/T,Western Union | Supply Ability | 100 sets per month |
| Delivery Time | 25-35 working days After receiving deposit | Packaging Details | Plywood Case+Foam |
| Product Name | Purification Glove Box | Model No. | GBP1000D-4 (1200) |
| Water Content | Less than 1PPM | Oxygen | '-3000pa~+3000pa |
| Leakage Rate | Less than 0.05 Vol %/h | Bearing Pressure | '-3000pa~+3000pa |
| Operating Side | Double Sided | Purification Column | Single or double at buyer's option |
| Brand Name | TENCAN | Model Number | GBP1000D-4 (1200) |
| Certification | CE ISO | Place of Origin | Hunan, China |
| High Light | Laboratory inert gas glove box ,Inert gas glove box with purification ,Dual access inert gas glove box | ||
Lab Standard Purification GBP1000D-4 1200 Inert Gas Glove Box with Two-sided Working Positions by Changsha Tencan
The Purification Glove Box from Changsha Tencan creates a highly controlled working atmosphere with minimal moisture and oxygen levels, making it suitable for handling air-sensitive materials. The system integrates a sealed main chamber, antechamber, gas purification module, digital control panel, vacuum components, and a real-time monitoring system. It can also be configured to operate alongside auxiliary laboratory equipment such as laser systems, vacuum deposition units, drying chambers, environmental analyzers, and exhaust treatment modules for fumes and volatile substances.
Engineered with a user-friendly layout and modern industrial design, Tencan glove boxes provide long-duration stable performance. Automated operation, simplified upkeep, and dependable functionality make them a reliable solution for both scientific research and production workflows.
With continuous investment in R&D, Changsha Tencan has built robust strengths in engineering design and technological advancement. Every step of the manufacturing cycle is subjected to strict quality control to ensure consistent output of high-level, precision-built products. Upholding standardized processes and customer-focused principles, we convert user feedback into ongoing optimization, continually delivering improved glove box systems that adapt to the changing demands of laboratories and industrial environments.
![]()
A Purification Glove Box is a specialized laboratory system designed to maintain an ultra-clean, oxygen-free and moisture-free environment by continuously circulating high-purity inert gas through the sealed chamber. Often referred to as an inert atmosphere glove box or gas-protection workstation, it effectively removes O₂, H₂O, and organic contaminants. This equipment is essential in research areas that require strictly controlled conditions—such as lithium battery development, advanced materials engineering, semiconductor fabrication, supercapacitor studies, precision lighting, welding technologies, OLED and MOCVD processes. It is also applicable in biological sciences, including anaerobic microbial cultivation and low-oxygen cell culture.
The glove box uses a fully sealed gas-circulation loop that connects the main chamber with the purification column filled with high-efficiency adsorbents for moisture and oxygen removal. Under PLC supervision, the system drives the working gas through pipelines and circulation blowers to pass repeatedly through the purification material. With each cycle, impurities are trapped, and purified gas re-enters the chamber. Over time, the internal levels of H₂O and O₂ drop to below 1 ppm. When the purification material becomes saturated after extended use, it can be regenerated to restore full performance and continue long-term operation.
Fundamental physical and chemical experiments
Manufacturing and research of specialty lighting
Lithium battery prototyping and production
Studies of alkali and highly reactive metals
Catalyst development
Precision welding technologies (laser, plasma, brazing)
Medical and biological engineering research
Pharmaceutical packaging and formulation
Semiconductor manufacturing processes
Chelation chemistry
Ceramic and metal powder investigation
Industrial processes requiring high-temperature vacuum conditions
Atmosphere Control: Achieves extremely low oxygen and moisture levels (<0.1 ppm)
Leak-Tight Structure: Overall leakage rate ≤0.001% volume/hour
Valve Configuration: Modular solenoid valve system for dependable sealing and easy service
Transfer System: Lightweight, smooth-operating antechamber door for efficient material loading
Exterior Variants: Multiple shell and appearance options suitable for different lab styles
User Interface: Simple, intuitive touchscreen control panel
Gas Circulation: Oil-free, vacuum-free closed-loop system for stable operation
Regeneration: Fully automated regeneration cycle for purification materials
Pressure Control: Automatic pressure balancing with adjustable ±15 mbar working range
Chamber Purge: Rapid automatic purging for fast drying and solvent-safe ventilation
Foot Pedal: Convenient hands-free internal pressure adjustment
Data Recording: Continuous system data logging and preservation
Alarm Mechanisms: Full monitoring and alerts for pressure, regeneration, and operational abnormalities
Sealing Technology: Multi-layer patented sealing structure for long-lasting stability
High-precision environmental control for handling sensitive materials
Modular build improves system reliability and maintenance convenience
Smart automation reduces manual workload and simplifies operation
Configurable system architecture to match specialized application needs
Proprietary sealing design ensures long-term airtight performance
Laboratory Standard Glove Box
1,Configuration of Laboratory Standard Glove Box
![]()
1.1 Glove box chamber
| Material | Stainless steel 1.4301 (SUS type 304), thickness 3 mm |
| Front Window | 8mm thick safe tempered glass or 10 mm thick polycarbonate (optional) |
| Glove Port | Hard aluminum alloy or daicel (optional), caliber 220 mm, O-ring seal |
| Gloves | Butyl rubber, thickness 0.4 mm or 0.8mm (optional), diameter 8 inches |
| Filter | One filter for each outlet and inlet, specifications<0.3μm |
| illumination | LED light is Inside the chimney above the top of the front window |
| Leakage Rate | ≤0.001VOL%/h |
| Rack | Built-in two-layer adjustable racks |
| Interface | Multiple KF40 backup interfaces |
1.2 Main Antechamber
| Chamber | Size | Diameter 360mm, length 600mm (optional diameter 390mm) |
| Chamber | Material | 304 Stainless steel |
| Chamber | Surface | wire drawing inner surface, painted exterior surface |
| Accessories | Tray | Stainless steel mirror processing, sliding tray |
| Accessories | Chamber door | Double doors, anodised aluminum, with booster structure |
| Accessories | Pressure gauge | Wika vacuum oil gauge or digital display |
| Control | Operation | PLC control or manual operation |
1.3 GP20 Gas Purification System
| Regeneration |
PLC automatic control regeneration process, effectively removing water and oxygen, single/double purification column optional. |
| Control System | Using microprocessors and equipped with a user-friendly human-machine interface. |
| Purification Column | Purification material: copper catalyst:7kgs,Molecular sie: 8kgs. Purification capacity: deoxygenization: 80L,dehydration 2.5kgs Single/double purification column optional |
| Vacuum Pump | Rotary vane pump, installed with oil mist filter, oil circulator, and automatic gas ballast control: 12m³/h (7cfm) vacuum degree < 2x10-3mbar dry pump (optional) |
| Circulation Unit | Oil-free high-speed inverter blower, oil-free, blast capacity 0-100 m³/h |
| Valve | KF40 high vacuum baffle valve, integrated German burkert solenoid valve module |
| Leak Rate | ≤0.001VOL%/h |
1.4 Mini Antechamber
| Mini Chamber | Size | Diameter 150mm,length 330mm |
| Mini Chamber | Material | 304 Stainless steel |
| Mini Chamber | Surface | Wire drawing inner surface, painted exterior surface |
| Accessories | Tray | Stainless steel mirror processing(optional accessories) |
| Accessories | Chamber door | Double doors, anodised aluminum, with booster structure |
| Accessories | Pressure gauge | Wika vacuum oil gauge or digital display |
| Control | Operation | PLC control or manual operation |
![]()
2.1 Interior Dimensions
Usable workspace: 1200 mm (L) × 900 mm (H) × 750 mm (W bottom).
2.2 Glove Ports
Two Ø220 mm glove rings made from corrosion-resistant hard aluminum alloy, suitable for organic processing environments.
2.3 Gloves
Imported butyl rubber gloves, model 8B1532 (USA).
Diameter 8 inches, thickness 0.4 mm, offering excellent resistance to chemicals, aging, and moderate heat.
2.4 Observation Window
Forward-tilted operation panel with 8 mm detachable tempered safety glass.
Highly transparent, abrasion-resistant, and corrosion-resistant.
Sealed with a 3/8" OMEGA gasket.
2.5 Operating Pressure Range
Maintains stable positive or negative pressure from –12 mbar to +12 mbar.
Automatic protection activates if pressure exceeds the safe range.
2.6 Lighting
Built-in anti-glare, energy-saving illumination with soft, comfortable lighting.
2.7 Internal Power Supply
Pre-installed sealed power interface board.
Input: AC 220V, 50Hz, single-phase, 10A.
2.8 Utility Ports
Multiple KF-40 universal interfaces for gas, liquid, and signal connections.
2.9 Shelving
Three internal adjustable shelves provided.
2.10 Support Frame
Cabinet stand height 950 mm with caster wheels enabling leveling, mobility, and locking.
2.11 Airtight Performance
Proprietary sealing structure ensuring a leakage rate of <0.001 vol%/hr.
3.1 Structure
Cylindrical 304 stainless steel construction with flange-mounted connections.
3.2 Large Antechamber
Diameter 360 mm, length 600 mm.
Features automatic valve operation for vacuum/purging cycles.
Programmable cycles minimize operator waiting time.
3.3 Small Antechamber
Diameter 150 mm, length 300 mm, manually controlled for air extraction and refill.
3.4 Internal Trays
Large chamber: polished sliding tray with extendable movement.
Small chamber: movable sliding platform included.
3.5 Vacuum Level
Achieves ≤ –0.1 MPa, equipped with German WIKA vacuum gauge.
4.1.1 Operation & Interface
Features auto-diagnosis, auto-restart, intelligent pressure regulation, and adaptive control.
All functions—including circulation, vacuum, and regeneration—are managed via PLC touchscreen (Chinese/English switchable).
4.1.2 Pressure Management
Touchscreen-controlled pressure with automatic balancing within set limits.
4.1.3 Foot Pedal
Allows fine pressure adjustments during experiments without stopping work.
4.2.1 Atmosphere Precision
Maintains <1 ppm H₂O and O₂, with 0.01 ppm detection accuracy.
4.2.2 Automated Control
PLC-driven evacuation, circulation, heating, and regeneration—no manual supervision needed.
4.2.3 Working Gas
Nitrogen or argon (99.999% purity required).
4.2.4 Circulation Fan
Variable-frequency high-speed fan (0–100 m³/h), enclosed in pressure-tested stainless housing.
4.2.5 Dual Purification Columns
Each column contains:
5 kg BASF Cu-based catalyst (deoxygenation, removes 65 L O₂)
5 kg UOP molecular sieve (removes 2.2 kg H₂O)
4.2.6 Purification Valve Block
German Burkert fully-automatic modular electric valve system.
4.2.7 Filtration
HEPA-grade 0.3 μm high-efficiency filter.
Uses N₂/H₂ or Ar/H₂ (5–10% H₂) mixture for full regeneration, restoring adsorption capacity.
PLC touchscreen with multilingual interface, intuitive menus, and data export support.
UK Edwards RV12 pump, 12 m³/h pumping speed.
Independently switchable and programmable shutdown via touchscreen to reduce energy consumption.
External solvent adsorption module prevents contamination of the purification column.
Contains 6 kg activated carbon for removing volatile organics.
British Michell analyzer, range 0–1000 ppm, ceramic alumina sensing element.
Fast response, corrosion-resistant, wide detection range.
U.S. AVCRAY electrochemical analyzer, range 0–1000 ppm.
Electrochemical sensor avoids instability issues of zirconia sensors in solvent environments.
9,Specifications of Standard Model of Purification Glove Box
| Item | Specifications | Description | Model | Power Supply |
Chamber Dimensions (mm) |
Outline Dimensions |
Purification Column |
Transit Cabin | Measurement (CBM) |
Net Weight (KGS) |
|
| 1 | 1200*750 |
Purification Glove Box (2 Glove ports/Single side) |
GBP750S-2 (1200) |
220V-50Hz 1 Phase |
1200*750*900 | 2000*1000*1950 | Single | 1 Small 1 Big |
0.8 | 400 | |
| 2 | 1500*750 | Purification Glove Box (3 Glove ports/single side) |
GBP750S-3 (1500) |
220V-50Hz 1 Phase |
1500*750*900 | 2300*1000*1950 | Single | 1 Small 1 Big |
1 | 450 | |
| 3 | 1800*750 | Purification Glove Box (4 Glove ports/Double sides) |
GBP750S-4 (1800) |
220V-50Hz 1 Phase |
1800*750*900 | 2600*1000*1950 | Single | 1 Small 1 Big |
1.2 | 500 | |
| 4 | 2400*750 | Purification Glove Box (4 Glove ports/Single sides) |
GBP750S-4 (2400) |
220V-50Hz 1 Phase |
2400*8750*900 | 3200*1000*1950 | Single | 1 Small 1 Big |
1.6 | 630 | |
| 5 | 1200*1000 | Purification Glove Box (4 Glove ports/Double sides) |
GBP1000D-4 (1200) |
220V-50Hz 1 Phase |
1200*1000*900 | 2000*1200*1950 | Single | 1 Small 1 Big |
1.1 | 500 |
| GBP1000D-4 (1200) |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2006
Total Annual:
3 millions-4 millions
Employee Number:
80~100
Ecer Certification:
Verified Supplier
CHANGSHA TIANCHUANG POWDER TECHNOLOGY CO., LTD. Changsha Tianchuang Powder Technology Company Limited, which was established in 2006, is located in Changsha City, Capital of Hunan Province, South-Centre part of People’s Republic of China. The Company is one of largest professiona... CHANGSHA TIANCHUANG POWDER TECHNOLOGY CO., LTD. Changsha Tianchuang Powder Technology Company Limited, which was established in 2006, is located in Changsha City, Capital of Hunan Province, South-Centre part of People’s Republic of China. The Company is one of largest professiona...
Get in touch with us
Leave a Message, we will call you back quickly!