Payment Terms | T/T, Western Union, L/C |
Supply Ability | 100000 sets per month |
Delivery Time | 15 days |
Packaging Details | CT VT Test Equipment packed in Plywood case |
Power supply | AC220V±10%, 50/60Hz±10% |
Display | LCD |
Test Standard | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 |
Voltage output | 0.1~180V (AC) |
Current output | 0.001~5A(RMS) |
Keyword | CT VT Test Equipment |
Test object | current transormer and voltage transformer |
Warranty | 1 Year |
Brand Name | AI |
Model Number | CPT-I |
Certification | ISO |
Place of Origin | China |
View Detail Information
Explore similar products
Touch Screen Transformer Test Equipment Sweep Frequency Response Analysis
Sweep Frequency Response Analysis Test Instrument for Transformer Testing
20A Transformer Test Equipment , Three Phase DC Winding Resistance Tester
Automatic TTR Transformer Turn Ratio Tester Single Or Three Phase
Product Specification
Payment Terms | T/T, Western Union, L/C | Supply Ability | 100000 sets per month |
Delivery Time | 15 days | Packaging Details | CT VT Test Equipment packed in Plywood case |
Power supply | AC220V±10%, 50/60Hz±10% | Display | LCD |
Test Standard | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 | Voltage output | 0.1~180V (AC) |
Current output | 0.001~5A(RMS) | Keyword | CT VT Test Equipment |
Test object | current transormer and voltage transformer | Warranty | 1 Year |
Brand Name | AI | Model Number | CPT-I |
Certification | ISO | Place of Origin | China |
High Light | Voltage Transformer Test Equipment ,VT Test Equipment ,CT Test Equipment |
Test for current transformer:
Excitation curve and parameters test
Turns ratio test
Ratio and phase error test
Polarity mark check
Winding resistance measurement
Secondary loop burden measurement
Error line curve test for protection CT
Transient CT parameters test
CT nameplate guess
Saturation hysteresis loop curve measurement
Tests for Potencial Transformer:
Turns ratio test
Ratio error and phase angle error test
Polarity test
Secondary burden test
Winding resistance test
Test for Voltage Transformer
Secondary burden test
Winding resistance test
Polarity test
Turns ratio test
Ratio error and phase angle error test
Applications of CT/ VT Test Equipment:
CT nameplate check
CT parameters check in work burden
CT transient parameters analysis
CT ratio and phase error calibration
PT routine test
Specifications:
Item Name | Fully Automatic CT VT Test Equipment | |
Test standards | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 | |
Power supply | AC220V±10%, 50/60Hz±10% | |
Voltage output | 0.1~180V (AC) | |
Current output | 0.001~5A(RMS) | |
Power output | 500VA | |
Max. knee voltage measurement | 45KV | |
Current measurement | Range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
Error | <±0.1%+0.01%FS |
Voltage measurement | Range | 0~200V (automatically change range in 1V/10V/70V/200V) | |
Error | < ±0.1%+0.01%FS | ||
Turns ratio measurement Range | 1~35000 1~2000, error<0.05% 2000~5000,error<0.1% 5000~35000,error<0.2% | ||
Phase measurement | error | ±2min | |
resolution | 0.01min | ||
Winding resistance measurement | Range | 0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm) | |
Error | < 0.2%RDG+0.02%FS | ||
Maximum resolution : 0.1mΩ | |||
Temperature measurement | -50~100 Celsius degree; error<3 Celsius degree | ||
CT Secondary burden | Range | 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) | |
Error | <0.2%RDG+0.02%FS | ||
Maximum resolution : 0.001ohm | |||
PT Secondary burden | Error | 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) | |
Maximum | <0.2%RDG+0.02%FS | ||
resolution | 0.1ohm | ||
PT ratio measurement | Range | 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% | |
PT ratio error measurement :Typical error<0.05%, Maximum Error<0.1% | |||
PT phase angle measurement maximum error < 3min | |||
Make evaluation for test results according to selected standards Make word report for test result Make word reports one time for multi-group test records on the PC Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test Compare excitation curves with saved excitation curves in the same window | |||
Memory capacity | >1000 groups test results | ||
Working condition temperature | -10℃~50℃; moist ≤90% |
Accessories List of CPT-I CT VT Test Equipment
Name | quantity | Description |
Main Unit | 1 Set | |
3M mask cable | 2 Roots | Test cable for power out and CT secondary connection |
10M mask cable | 1 Root | Test cable for CT primary connection |
Grounding cable | 1 Root | |
Big test pliers | 2 PCS | One red and one black |
Test gasket | 4 PCS | Two red and two black |
Test pin | 4 PCS | Two red and two black |
Test pliers | 12 PCS | Three red and nine black |
Short connection cable | 1 Root | Including six connection terminals |
3A fuse | 3 PCS | |
Power cable | 1 Root | |
Accessories bag | 1 PC | |
Production disk | 1 PC | Include Analysis application and user manual |
User manual | 1 Copy | |
Inspection report | 1 Copy |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2018
Total Annual:
1,000,000-5,000,000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Advanced Instruments Co.,Limited. is a professional supplier which is committed to offer best testing equipment from China for our clients,and our main products are fire rating testing equipment,petroleum products testing equipment,electrical testing equipment geophysical equipment and general labor... Advanced Instruments Co.,Limited. is a professional supplier which is committed to offer best testing equipment from China for our clients,and our main products are fire rating testing equipment,petroleum products testing equipment,electrical testing equipment geophysical equipment and general labor...
Get in touch with us
Leave a Message, we will call you back quickly!