| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability | 30 Sets per Month Haida |
| Delivery Time | 15 days after order confirmed |
| Packaging Details | Export wooden case |
| Display Device | PC |
| Unit Switchover | G, KG, N, LB |
| Usage | Tension Material Tension Strength Tester |
| Force Reading | kgf, Ibf, N, KN, T etc |
| Grip | Tensile grip, Tear force grip |
| Brand Name | Haida |
| Model Number | HD-E900 |
| Certification | ISO,CE |
| Place of Origin | Guangdong, China (Mainland) |
View Detail Information
Explore similar products
8100-HD HVDC Power-Supply Module with 700V to 5V Direct Conversion, 450A Current
8100-HD HVDC Power-Supply Module with 700V to 5V Direct Conversion, 450A Current
8102-HD Digital HVDC Simulation Platform with High-Precision Real-Time
Solar Photovoltaic Rapid-rate Thermal Cycle Test Chamber PV Circuit Continuity
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Supply Ability | 30 Sets per Month Haida |
| Delivery Time | 15 days after order confirmed | Packaging Details | Export wooden case |
| Display Device | PC | Unit Switchover | G, KG, N, LB |
| Usage | Tension Material Tension Strength Tester | Force Reading | kgf, Ibf, N, KN, T etc |
| Grip | Tensile grip, Tear force grip | Brand Name | Haida |
| Model Number | HD-E900 | Certification | ISO,CE |
| Place of Origin | Guangdong, China (Mainland) | ||
| High Light | PID test machine for PV modules ,HD-E900 solar panel tester ,PV module degradation testing equipment | ||
Potential Induced Degradation (PID) testing evaluates the ability of photovoltaic modules to resist potential-induced deterioration by simulating harsh electric field and humid heat conditions.
| Item | Specification |
|---|---|
| DC Regulated Power Supply | 12 channels(Independently monitoring and control) Each channel can independently control the voltage polarity |
| Voltage range | -2000V ~ 2000V |
| Voltage resolution | 1V |
| Voltage stability | For continuous output of 1000V, 1500V, and 2000V, voltage fluctuation is ≤2% within 500 hours |
| Connection method | Module frame grounded, connector shorted and then connected to the high-voltage terminal; for negative voltage testing and positive voltage recovery, only switch toggling is needed, no change in connection method required |
| Voltage application method | 20 power channels operate independently, capable of outputting different polarities and voltages |
| Voltage accuracy | ±3% (referencing CNAS-CL01-A021:2018) |
| Voltage tolerance | 0.5% (referencing IEC 62804-1-1:2020) |
| Current measurement range | 0~1mA Resolution: 0.01μA (as specified in IEC 62804-1-1:2020) |
| Acquisition interval | ≤5min(adjustable at software) |
| Safety protection features | Overcurrent alarm, overvoltage alarm, overtemperature alarm, communication interface with environmental test chamber |
| Power | Single phase, 220V, 50Hz |
| Items | Description |
|---|---|
| Test Standard | IEC61215-2: 2021 MQT 21 Potential Induced Degradation Test IEC 62804-1-1:2020“Photovoltaic (PV) modules - Test methods for the detection of potential-induced degradation Part 1-1 Crystalline silicon – Delamination" IEC 63209:2019 Extended-stress testing of photovoltaic modules |
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2004
Total Annual:
$ 5 Million-US$ 10 Million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibra... Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibra...
Get in touch with us
Leave a Message, we will call you back quickly!