China Fully Automatic Effluent Treatment Equipment Fully Submerged Fiber Rotary Disk
China Fully Automatic Effluent Treatment Equipment Fully Submerged Fiber Rotary Disk

  1. China Fully Automatic Effluent Treatment Equipment Fully Submerged Fiber Rotary Disk

Fully Automatic Effluent Treatment Equipment Fully Submerged Fiber Rotary Disk

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Productname Effluent Treatment Equipment
Effluenttype Industrial Wastewater
Capacity (m³/d) 600-50000
Type Fully Automatic
Brand Name Lanjiang
Model Number ZP Series
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Productname Effluent Treatment Equipment
Effluenttype Industrial Wastewater Capacity (m³/d) 600-50000
Type Fully Automatic Brand Name Lanjiang
Model Number ZP Series Place of Origin China
High Light Effluent Treatment Fiber Rotary Disk FilterFully Submerged Fiber Rotary Disk FilterFully Automatic Effluent Treatment Equipment
Fully Submerged Fiber Rotary Disk Filter
Minimal Installed Power | Ultra-Small Footprint | Existing Sewage Plant Upgrades
Product Overview
The Fully Submerged Fiber Rotary Disk Filter is highly efficient, energy-saving equipment designed for solid-liquid separation and advanced water treatment. This system features a central rotating drum, filtering disk panels, backwashing system, and supporting electrical controls for optimal performance.
Operating Principle
Raw water flows through special fiber filter cloth on the disks into the drum, with filter pores as fine as 10μm effectively intercepting impurities. When accumulated impurities cause liquid level to reach set value, the backwash device automatically activates, suctioning trapped debris into sewage pipes for discharge.
Applications
Extensively used for upgrading existing wastewater treatment plants (improving from Class 1B to Class 1A discharge standards), reusing industrial production water (cooling water in steel and power plants), urban miscellaneous water reuse, and aquaculture water treatment.
Technical Specifications
Model Disk Dia. (m) Single Disk Area (m²) Number of Disks Capacity (m³/d) Installed Power (kw)
ZP1.2-2 1.2 2.0 2 600 0.37+1.5
ZP1.2-8 1.2 2.0 8 2400 0.37+3
ZP2-2 2.0 5.8 2 2000 0.55+2.2
ZP2-10 2.0 5.8 10 10000 0.75+4.4
ZP2-20 2.0 5.8 20 20000 0.75+6.6
ZP3-2 3.0 12.6 2 5000 0.75+3.7
ZP3-10 3.0 12.6 10 25000 1.1+7.4
ZP3-20 3.0 12.6 20 50000 1.1+11.1
Note: The table above features a selected range of models; disk quantity and capacity can be flexibly configured based on actual processing requirements.
Key Advantages
  • Minimal Installed Power for Extreme Energy Savings: Normal filtration operates entirely via gravity flow with zero energy consumption, keeping operating costs incredibly low.
  • High Space Utilization with Small Footprint: Vertical space optimization creates compact arrangements that save valuable plant area and enable convenient centralized management.
  • Fully Automatic Continuous Operation: System runs continuously under automated control with no interruption during backwash cycles, eliminating operational downtime.
  • Superior Water Quality & Impact Resistance: Tolerates influent SS up to 50mg/L and guarantees stable effluent quality achieving SS ≤ 5mg/L standards.
Frequently Asked Questions
Will the normal water filtration be interrupted when the equipment is backwashing?
No, it will not. The equipment is designed for automated continuous operation. When the backwash device is active, filtration continues simultaneously on other disk areas, ensuring completely uninterrupted water supply.
Is the head loss high, and does the small pore size cause easy clogging?
The head loss is remarkably small, typically set at just 300mm. When impurities accumulate and trigger the set liquid level, the efficient backwash system immediately activates to clear debris and prevent clogging.
Does this equipment consume a lot of electricity, and does it require external clean water for backwashing?
Power consumption is extremely low as standard filtration relies on gravity. The backwashing system uses filtered water from inside the central drum, requiring no external tap water while maintaining highly efficient backwashing energy usage.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    40000000-70000000

  • Employee Number:

    80~100

  • Ecer Certification:

    Verified Supplier

Nanjing Lanjiang is a professional manufacturer integrating the design, research and development, production, and sales of wastewater treatment equipment. The company is located at No.18 Xinyu Road, Hengliang Street, Liuhe District, in the northern suburbs of Nanjing (adjacent to the Ningtong Expres... Nanjing Lanjiang is a professional manufacturer integrating the design, research and development, production, and sales of wastewater treatment equipment. The company is located at No.18 Xinyu Road, Hengliang Street, Liuhe District, in the northern suburbs of Nanjing (adjacent to the Ningtong Expres...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Lanjiang Water Treatment Equipment Co., Ltd
  • No.18, Xinyu Road, Hengliang Street, Luhe District, Nanjing, Jiangsu Province, China.
  • https://www.lanjiangwatertreatment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement