Manufacturer of a wide range of products which include Low Noise Water Fog Generator 210W For Airflow Balance Testing,Pharmaceutical Cleanroom Pure Water Fog Generator Machine CE Approved,Laser Sensor Air Particle Counter 0.5μm-1...
MOQ: 1pc
Price: Negotiation
| Name | Water Fog Generator |
| Product features | Low noise, ≤50dB |
| Applications | Airflow balance testing |
| Model | KQ-W210 |
| Power supply | AC 220V 50Hz |
| Water filling capacity | 2500ml (max. 3000ml) |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Payment Terms | T/T |
| Supply Ability | 100 units/month |
MOQ: 1pc
Price: Negotiation
| Name | Water Fog Generator |
| Power supply | AC 220V 50Hz |
| Dimension | W265×D280×H300 mm |
| Weight | 9Kg |
| Power rating | 210W |
| Water filling capacity | 2500ml (max. 3000ml) |
| Fogging volume | ≥5500ml/h |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Payment Terms | T/T |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-W210 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Particle Size Channels | 0.3μm,0.5μm,1.0μm,3.0μm,5.0μm,10.0μm |
| Sampling Flow Rate | 100L/min±5% |
| Particle Size Distribution Error | ≤±20% |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Name | Air Particle Counter |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Name | Portable Particle Counter |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Particle Size Channels | 0.3μm-10.0μm |
| Particle Size Distribution Error | ≤±20% |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Sampling Flow Rate | 100L/min±5% |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Particle Size Channels | 0.3μm,0.5μm,1.0μm,3.0μm,5.0μm,10.0μm |
| Sampling Flow Rate | 100L/min±5% |
| Particle Size Distribution Error | ≤±20% |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Name | Air Particle Counter |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Name | Light Scattering Airborne Particle Counter |
| Particle Size Channels | 0.2μm - 10.0μm |
| Sampling Flow Rate | 100L/min±5% |
| Particle Size Distribution Error | ≤±20% |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Supply Ability | 100 units/month |
| Delivery Time | 5 work days |
| Packaging Details | Carton |
| Name | Air Particle Counter |
| Particle size distribution error | ≤±20% |
| Repetition error | ±5%F.S |
| Particle size channel | 0.2μm-10.0μm |
| Sampling flow rate | 2.83L/min(0.1CFM)±5% |
| Concentration error | 0.5μm≤±20%FS |
| Brand Name | KQET |
| Model Number | KQ-4001 |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Supply Ability | 100 units/month |
| Delivery Time | 5 work days |
| Packaging Details | Carton |
| Particle size channel | 0.2μm -10.0μm |
| Sampling flow rate | 2.83L/min(0.1CFM)±5% |
| Particle size distribution error | ≤±20% |
| Concentration error | 0.5μm≤±20%FS |
| Repetition error | ±5%F.S |
| Name | Air Particle Counter |
| Brand Name | KQET |
| Model Number | KQ-4001 |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Name | Air Particle Counter |
| Sampling Flow Rate | 100L/min±5% |
| Particle Size Distribution Error | ≤±20% |
| Particle Size Channels | 0.3μm-10.0μm |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |
MOQ: 1pc
Price: Negotiation
| Payment Terms | T/T |
| Packaging Details | Carton |
| Delivery Time | 5 work days |
| Supply Ability | 100 units/month |
| Name | Condensation Particle Counter CPC |
| Particle Size Channels | 0.3μm-10.0μm |
| Concentration Error | 0.5μm≤±20%FS |
| Repetition Error | ±5%F.S |
| Particle Size Distribution Error | ≤±20% |
| Sampling Flow Rate | 100L/min±5% |
| Sampling Period | User-settable (1 to 9999 seconds) |
| Sampling Delay | User-settable (1 to 999 seconds) |
| Brand Name | KQET |
| Model Number | KQ-4100 |
| Certification | CE |
| Place of Origin | China |