Payment Terms | T/T, Western Union, MoneyGram |
Supply Ability | 500 pcs per month |
Delivery Time | 5-7 days |
Packaging Details | Aluminum box |
product name | Fractional CO2 Laser |
technology | Medical CO2 Laser Machine |
function | Dermatology CO2 Laser |
Working Mode | Single pulse, Continuous pulse, Repeated pulse |
Laser Type | Metal Tube |
Laser Wavelength | 10600nm |
Output Power | 60W |
Input Power | 450VA |
Operation Modes | Pulsed, Ultra Pulsed, Continuous |
Pulse Width | 0.02–0.99s |
Pulse Duration | 1–100μs |
Scan Patterns | Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence | 4mrad |
Focused Spot Diameter | 120–240μm |
Aiming Beam | Infrared Ray (630–650nm, <5mW) |
Beam Delivery | 7-joint articulated arm, 360° rotation |
Cooling System | Internal circulation cooling |
Display Screen | True color LCD touch screen |
Operation System | Microcomputer control |
Input Voltage | AC220V ±10%, 50Hz |
Probes | Scanner probe, Vaginal probe, Surgical probe |
Brand Name | GOMECY |
Model Number | GMS C5 Verticle |
Certification | CE |
Place of Origin | Beijing |
View Detail Information
Explore similar products
GOMECY 2024 Facial Skin Care Co2 Fractional Laser Stretch Mark Fractional Co2
Fractional Laser Skin Treatment Scar Stretch Marks Removal Co2 Fractional Laser
60W Fractional Treatment Co2 Laser Skin Rejuvenation Machine 10600nm
60W Fractional Skin Resurfacing Acne Treatment Anti Puffiness CO2 Laser
Product Specification
Payment Terms | T/T, Western Union, MoneyGram | Supply Ability | 500 pcs per month |
Delivery Time | 5-7 days | Packaging Details | Aluminum box |
product name | Fractional CO2 Laser | technology | Medical CO2 Laser Machine |
function | Dermatology CO2 Laser | Working Mode | Single pulse, Continuous pulse, Repeated pulse |
Laser Type | Metal Tube | Laser Wavelength | 10600nm |
Output Power | 60W | Input Power | 450VA |
Operation Modes | Pulsed, Ultra Pulsed, Continuous | Pulse Width | 0.02–0.99s |
Pulse Duration | 1–100μs | Scan Patterns | Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence | 4mrad | Focused Spot Diameter | 120–240μm |
Aiming Beam | Infrared Ray (630–650nm, <5mW) | Beam Delivery | 7-joint articulated arm, 360° rotation |
Cooling System | Internal circulation cooling | Display Screen | True color LCD touch screen |
Operation System | Microcomputer control | Input Voltage | AC220V ±10%, 50Hz |
Probes | Scanner probe, Vaginal probe, Surgical probe | Brand Name | GOMECY |
Model Number | GMS C5 Verticle | Certification | CE |
Place of Origin | Beijing |
The CO₂ laser is a high-energy system that emits light at a wavelength of 10600nm, which is strongly absorbed by water in biological tissues. Because human skin and mucosa are rich in water, this laser is highly effective in cutting, vaporizing, and coagulating soft tissue with excellent precision.
The device uses fractional scanning technology and different probes to adapt to dermatology, gynecology, and surgical procedures.
In dermatology, the fractional CO₂ laser creates microthermal zones in the skin, stimulating collagen regeneration and improving skin texture, wrinkles, scars, and pigmentation.
In gynecology, the CO₂ vaginal probe promotes mucosal regeneration, improves tissue elasticity, and restores vaginal health.
In surgery, the precise cutting ability allows minimally invasive operations with reduced bleeding and faster healing.
This combination of applications makes it a versatile solution for clinical and cosmetic needs.
Skin resurfacing and rejuvenation
Reduction of fine lines and wrinkles
Scar improvement (acne scars, surgical scars, burn scars)
Pigmentation treatment
Skin tightening and pore reduction
Vaginal tightening and rejuvenation
Improvement of dryness and laxity
Postpartum tissue restoration
Supportive therapy for mild incontinence
Cutting and vaporization of soft tissue
Coagulation to reduce bleeding
Precise excision with minimal damage to surrounding tissue
Parameter | Specification |
---|---|
Working Mode | Single pulse, Continuous pulse, Repeated pulse |
Laser Type | Metal Tube |
Laser Wavelength | 10600nm |
Output Power | 60W |
Input Power | 450VA |
Operation Modes | Pulsed, Ultra Pulsed, Continuous |
Pulse Width | 0.02–0.99s |
Pulse Duration | 1–100μs |
Scan Patterns | Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence | 4mrad |
Focused Spot Diameter | 120–240μm |
Aiming Beam | Infrared Ray (630–650nm, <5mW) |
Beam Delivery | 7-joint articulated arm, 360° rotation |
Cooling System | Internal circulation cooling |
Display Screen | True color LCD touch screen |
Operation System | Microcomputer control |
Input Voltage | AC220V ±10%, 50Hz |
Probes | Scanner probe, Vaginal probe, Surgical probe |
Versatile Probes: Equipped with scanner, gynecological, and surgical handpieces.
Fractional Scanning: Adjustable scan patterns and spot sizes for tailored treatments.
Precision Cutting: Ultra-pulsed mode for delicate surgical applications.
Smart Control System: Microcomputer-based, user-friendly interface.
Efficient Cooling: Built-in circulation ensures stable performance.
Ergonomic Design: 7-joint articulated arm provides flexibility and accuracy.
Cleanse the treatment area.
Apply topical anesthesia if needed.
Select scan pattern, energy level, and pulse duration.
Deliver fractional CO₂ laser to target area.
Apply cooling gel or soothing mask after treatment.
Gynecological evaluation and patient preparation.
Apply local anesthesia or numbing gel if required.
Insert vaginal probe gently.
Deliver laser energy in fractional mode for mucosal stimulation.
Patient may resume normal activity within 1–2 days.
Prepare surgical site under aseptic conditions.
Adjust laser mode (pulsed, continuous, or ultra-pulsed).
Perform incision, vaporization, or coagulation as needed.
Minimal bleeding due to coagulation effect.
Postoperative dressing and care.
Avoid sun exposure and tanning for at least 2 weeks before treatment.
Do not use retinoids or exfoliating agents 1 week prior.
Inform the doctor about any medications or medical history.
For gynecology, ensure no active infection or menstruation period.
Apply prescribed soothing ointments to the treated area.
Avoid hot baths, sauna, and strenuous exercise for 1 week.
Keep the treated skin clean and moisturized.
Use sunscreen daily to prevent pigmentation.
For gynecological procedures, avoid activity for 5–7 days.
Pregnancy and breastfeeding
Severe systemic diseases (uncontrolled diabetes, cardiovascular conditions)
Active infections or open wounds at the treatment site
History of keloid formation or abnormal scarring
Blood clotting disorders or use of anticoagulants
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2006
Total Annual:
10,000,000-50,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa... Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa...
Get in touch with us
Leave a Message, we will call you back quickly!