China factories

Chat Now Send Email
China factory - Changsha GOMECY Electronics Limited

Changsha GOMECY Electronics Limited

  • China,Beijing ,Beijing
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati

  1. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
  2. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
  3. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
  4. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
  5. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati
  6. China Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati

Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenati

  1. MOQ: 1
  2. Price: USD 5299~5899
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 500 pcs per month
Delivery Time 5-7 days
Packaging Details Aluminum box
product name Fractional CO2 Laser
technology Medical CO2 Laser Machine
function Dermatology CO2 Laser
Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube
Laser Wavelength 10600nm
Output Power 60W
Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous
Pulse Width 0.02–0.99s
Pulse Duration 1–100μs
Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad
Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW)
Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling
Display Screen True color LCD touch screen
Operation System Microcomputer control
Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe
Brand Name GOMECY
Model Number GMS C5 Verticle
Certification CE
Place of Origin Beijing

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 500 pcs per month
Delivery Time 5-7 days Packaging Details Aluminum box
product name Fractional CO2 Laser technology Medical CO2 Laser Machine
function Dermatology CO2 Laser Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube Laser Wavelength 10600nm
Output Power 60W Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous Pulse Width 0.02–0.99s
Pulse Duration 1–100μs Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW) Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling Display Screen True color LCD touch screen
Operation System Microcomputer control Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe Brand Name GOMECY
Model Number GMS C5 Verticle Certification CE
Place of Origin Beijing

Gynecology CO2 Laser System

1. What is CO₂ Laser Technology?

The CO₂ laser is a high-energy system that emits light at a wavelength of 10600nm, which is strongly absorbed by water in biological tissues. Because human skin and mucosa are rich in water, this laser is highly effective in cutting, vaporizing, and coagulating soft tissue with excellent precision.

The device uses fractional scanning technology and different probes to adapt to dermatology, gynecology, and surgical procedures.

  • In dermatology, the fractional CO₂ laser creates microthermal zones in the skin, stimulating collagen regeneration and improving skin texture, wrinkles, scars, and pigmentation.

  • In gynecology, the CO₂ vaginal probe promotes mucosal regeneration, improves tissue elasticity, and restores vaginal health.

  • In surgery, the precise cutting ability allows minimally invasive operations with reduced bleeding and faster healing.

This combination of applications makes it a versatile solution for clinical and cosmetic needs.

2. Applications

Dermatology

  • Skin resurfacing and rejuvenation

  • Reduction of fine lines and wrinkles

  • Scar improvement (acne scars, surgical scars, burn scars)

  • Pigmentation treatment

  • Skin tightening and pore reduction

Gynecology

  • Vaginal tightening and rejuvenation

  • Improvement of dryness and laxity

  • Postpartum tissue restoration

  • Supportive therapy for mild incontinence

Surgery

  • Cutting and vaporization of soft tissue

  • Coagulation to reduce bleeding

  • Precise excision with minimal damage to surrounding tissue

3. Product Parameters

Parameter Specification
Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube
Laser Wavelength 10600nm
Output Power 60W
Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous
Pulse Width 0.02–0.99s
Pulse Duration 1–100μs
Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad
Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW)
Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling
Display Screen True color LCD touch screen
Operation System Microcomputer control
Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe

4. Product Features

  • Versatile Probes: Equipped with scanner, gynecological, and surgical handpieces.

  • Fractional Scanning: Adjustable scan patterns and spot sizes for tailored treatments.

  • Precision Cutting: Ultra-pulsed mode for delicate surgical applications.

  • Smart Control System: Microcomputer-based, user-friendly interface.

  • Efficient Cooling: Built-in circulation ensures stable performance.

  • Ergonomic Design: 7-joint articulated arm provides flexibility and accuracy.

5. Treatment Steps

Dermatology (fractional resurfacing)

  1. Cleanse the treatment area.

  2. Apply topical anesthesia if needed.

  3. Select scan pattern, energy level, and pulse duration.

  4. Deliver fractional CO₂ laser to target area.

  5. Apply cooling gel or soothing mask after treatment.

Gynecology

  1. Gynecological evaluation and patient preparation.

  2. Apply local anesthesia or numbing gel if required.

  3. Insert vaginal probe gently.

  4. Deliver laser energy in fractional mode for mucosal stimulation.

  5. Patient may resume normal activity within 1–2 days.

Surgery

  1. Prepare surgical site under aseptic conditions.

  2. Adjust laser mode (pulsed, continuous, or ultra-pulsed).

  3. Perform incision, vaporization, or coagulation as needed.

  4. Minimal bleeding due to coagulation effect.

  5. Postoperative dressing and care.

6. Pre-Treatment Guidelines

  • Avoid sun exposure and tanning for at least 2 weeks before treatment.

  • Do not use retinoids or exfoliating agents 1 week prior.

  • Inform the doctor about any medications or medical history.

  • For gynecology, ensure no active infection or menstruation period.

7. Post-Treatment Care

  • Apply prescribed soothing ointments to the treated area.

  • Avoid hot baths, sauna, and strenuous exercise for 1 week.

  • Keep the treated skin clean and moisturized.

  • Use sunscreen daily to prevent pigmentation.

  • For gynecological procedures, avoid activity for 5–7 days.

8. Contraindications

  • Pregnancy and breastfeeding

  • Severe systemic diseases (uncontrolled diabetes, cardiovascular conditions)

  • Active infections or open wounds at the treatment site

  • History of keloid formation or abnormal scarring

  • Blood clotting disorders or use of anticoagulants

Gynecology CO2 Laser System

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2006

  • Total Annual:

    10,000,000-50,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa... Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa...

+ Read More

Get in touch with us

  • Reach Us
  • Changsha GOMECY Electronics Limited
  • Block A, 1/F Jinri Science Park, No. 26 Jinyuan Road, Daxing District,Beijing, China
  • https://www.gomecy.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement