| Payment Terms | L/C, T/T |
| Supply Ability | 2000 Units per month |
| Delivery Time | 1-2 months |
| Packaging Details | Carton Pallet Container |
| Working voltage range | S50mA(12V)/s25mA(24V) |
| CAN communication | 1 Channel |
| Single cell detection range | 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage |
| Voltage acquisition accuracy | ±5mV |
| Temperature detection accuracy ±2°C | ±2°C |
| Balance function | Support, passive balancing |
| Balanced number of opening routes | Every 8 channels can activate 1 channel equalization |
| Digital signal power input | Max120mA,effective value 30-50mA |
| Automatic address allocation | Support |
| Io output | 2-way dry contact, rated 2A, passive output |
| Bootloader | Support CAN bus burning and writing |
| Anti reverse connection of power supply | Support |
| Power surge prevention | Support |
| Brand Name | Ecolite/OEM/ODM |
| Place of Origin | China |
View Detail Information
Explore similar products
Intelligent BMS Battery Management System Lithium Battery LifePO4 12V Protection
YKN-BMS8S Intelligent Battery Management System BMS For Small Energy Storage
ECOLTO Intelligent Battery Management System YKN-BMS16S 100A / 200A
Highly Functional Level 3 High Voltage Battery BMS For Energy Storage BAU
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 2000 Units per month |
| Delivery Time | 1-2 months | Packaging Details | Carton Pallet Container |
| Working voltage range | S50mA(12V)/s25mA(24V) | CAN communication | 1 Channel |
| Single cell detection range | 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage | Voltage acquisition accuracy | ±5mV |
| Temperature detection accuracy ±2°C | ±2°C | Balance function | Support, passive balancing |
| Balanced number of opening routes | Every 8 channels can activate 1 channel equalization | Digital signal power input | Max120mA,effective value 30-50mA |
| Automatic address allocation | Support | Io output | 2-way dry contact, rated 2A, passive output |
| Bootloader | Support CAN bus burning and writing | Anti reverse connection of power supply | Support |
| Power surge prevention | Support | Brand Name | Ecolite/OEM/ODM |
| Place of Origin | China | ||
| High Light | High Voltage Battery Management System ,BMS Battery Management System ,OEM High Voltage BMS | ||
Ecolite Highly Functional Level 3 High Voltage Battery Management System for Energy Storage BMU64
Diagram of Energy storage Level 3 Architecture System:
Level 3 battery system architecture: First level control: BAU centrally man-ages the various clusters of batteries inthe battery array, and communicateswith external PCS, UPS, EMS, airconditioning, liquid cooling, fire protec-tion, etc;
Secondary control: BCU1~BCUmmanaging each cluster of batteriescollecting cluster battery information,high-voltage control, and uploadingcluster information to BAU;
Slave control:BMU1~BMUn, responsi-ble for collecting battery voltage,temperature and otherinformation ofthe battery module.
| Products | Function configuration | |||||
| BCU | Parameter | MinimumValue | TypicalValue | Maximum UnitValue | Description | |
| Power input | 9 | 24 | 32 | v | ||
| Working current | 180 | 125 | 130 | mA | ||
| Rated power | S3 | W | ||||
| CAN BuS | 3 | Channel | 2-wayisolation,1-way non isolation | |||
| 485 Bus | 2 | Channel | 2-way isolation | |||
| LAN interface (TCP/P) | 1 | Channel | ||||
| High edge output | 8+2 | Channel | 2-way support for PWM output | |||
| Switching input detection | 9 | Channel | solaed acise dee prosive detection, 1 -way | |||
| Dry node output | 2 | Channel | Rated 2A, passive output | |||
| Temperature detection | 4 | Channel | +2℃℃,-40~125°℃,supports NTC-10K,100K | |||
| Total voltage detection channel | 3 | Channel | 1 channel supports main and negative relayadhesion detection | |||
| Total voltage detection range | 12 | 1500 | V | Total pressure detection error ≤ 0.3% | ||
| Manage the rated voltage ofthe battery pack | 1500 | V | Rasrocltage ssoy, withstand voltage AC3100+,DC4380+ |
|||
| Supports the number of BMU | 40 | PCS | ||||
| Detect the total | 6 | 500 | Strand | Used in | ||
| Number of battery strings | Conjunction with BMU | |||||
| Current detection | 2 | Channel | Supports 1 splitter,1 Hall(supports 5v,12v), and can collect data simultaneously |
|||
| Current detection range | -1500 | 1500 | A | Range optional | ||
| Current detection error | 0 | 1 | 1%FSR | A | Typical error 0.5% FSR, maximum error 1% FSR | |
| Insulation testing | 15% | KΩ | 0-200KΩ,error<15KΩ;>200KΩ,eror≤+15% | |||
| BCU automatic addressing | support | lsolation type, level signal addressed | ||||
| SOC estimation error | 0 | 3% | 5% | ≤5% | ||
| SOH estimation accuracy | 0 | 3% | 10% | |||
| SOE estimation accuracy | 0 | 3% | 5% | |||
| Products | Function configuration | |||||
| BAU | Parameter | MinimumValue | TypicalValue | Maximum UnitValue | Description | |
| Power input | 9 | 24 | 32 | v | ||
| Working current | 180 | 200 | 220 | mA | ||
| Rated power | ≤5 | W | ||||
| CAN Bus | 4 | Channel | lsolation communication | |||
| 485 Bus | 4 | Channel | lsolation communication | |||
| USB interface | 1 | Channel | Used for external data storage, default 32/64G | |||
| LAN interface (TCP/IP) | 2 | Channel | ||||
| Relay drive output (RL) | 4 | Channel | ||||
| Dry node output (DO) | 4 | Channel | Rated 2A, passive dry node | |||
| Digital Input (DlH) | 2 | Channel | High level detection | |||
| Digital Input (DlL) | 2 | Channel | Low level detection | |||
| Digital signal power input | 1 | Channel | lsolation signal detection power supply | |||
| Supports the number of BCU | 30 | PCS | ||||
| Products | Function configuration | ||||
| BMU | Parameter | BMU16 | BMU32 | BMU48 | BMU64 |
| Working voltage range | 9~32V | ||||
| Working voltage range | S50mA(12V)/s25mA(24V) | ||||
| Rated power | ≤0.6W | ||||
| CAN communication | 1 Channel | ||||
| Number of voltage acquisitionstrings | 16 | 32 | 48 | 64 | |
| Temperature detection point | 4 | 8 | 12 | 16 | |
| Single cell detection range | 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage | ||||
| Voltage acquisition accuracy | ±5mV | ||||
| Temperature detection accuracy ±2°C | ±2°C | ||||
| Balance function | Support, passive balancing | ||||
| Balanced number of opening routes | Every 8 channels can activate 1 channel equalization | ||||
| Digital signal power input | Max120mA,effective value 30-50mA | ||||
| Automatic address allocation | Support | ||||
| Io output | 2-way dry contact, rated 2A, passive output | ||||
| Analog input detection | 2-way (high edge detection) | ||||
| Bootloader | Support CAN bus burning and writing | ||||
| CAN communication | 1 Channel | ||||
| Anti reverse connection of power supply | Support | ||||
| Power surge prevention | Support | ||||
| Voltage resistance | Voltage withstand AC3100+,DC4380+ | ||||
| Working temperature | -40°C~85°C | ||||
| Storage temperature | -40°C~125°C | ||||
| Protection level | IP43, Not waterproof | ||||
| Humidity | <95%,No condensation | ||||
| Shock | ≤5500m | ||||
| Automatic address allocation | At 10-25Hz,the amplitude is 1.2mm: At 26-500Hz,maximum 30m/S | ||||
| Drop | 1.5m, 5 times in both horizontal and vertical directions, no damage to PCBA, no change in performance | ||||
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2014
Total Annual:
10,000000-15000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Hefei Ecolite Energy Co., Ltd. is a professional manufacturer of lithium-ion batteries and energy storage solutions, located in Hefei City, Anhui Province, China. Founded in 2014, Ecolite has been focusing on the development and manufacturing of lithium battery products and customized energy solut... Hefei Ecolite Energy Co., Ltd. is a professional manufacturer of lithium-ion batteries and energy storage solutions, located in Hefei City, Anhui Province, China. Founded in 2014, Ecolite has been focusing on the development and manufacturing of lithium battery products and customized energy solut...
Get in touch with us
Leave a Message, we will call you back quickly!