China factories

Chat Now Send Email
China factory - Wuxi Fenigal Science & Technology Co., Ltd.

Wuxi Fenigal Science & Technology Co., Ltd.

  • China,Wuxi ,Jiangsu
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC
China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC

  1. China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC
  2. China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC
  3. China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC
  4. China ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC

ABB MS116 Manual Starter Switch 3 Pole 0.1~32A 230/400V 440V Icu Up To 50kA IEC

  1. MOQ: 1 unit
  2. Price: USD35~USD50
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 1,000pcs/month
Delivery Time 5-8 working days
Packaging Details Standard export carton
Product name Manual Motor Starter, Motor Protection Circuit Breaker
Rated voltage 440/690,230/400V, 500V AC 50/60Hz
Setting current 0.1-0.16~25-32A
Poles number 3P
Breaking capacity 10-50kA
Material Plastic,High Standard Plastic Silver Copper,Nylon PA66
Installation Fixed and Plug-in
Standard IEC 60947-2
Brand Name ABB
Model Number MS116
Certification CE, CCC etc.
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 1,000pcs/month
Delivery Time 5-8 working days Packaging Details Standard export carton
Product name Manual Motor Starter, Motor Protection Circuit Breaker Rated voltage 440/690,230/400V, 500V AC 50/60Hz
Setting current 0.1-0.16~25-32A Poles number 3P
Breaking capacity 10-50kA Material Plastic,High Standard Plastic Silver Copper,Nylon PA66
Installation Fixed and Plug-in Standard IEC 60947-2
Brand Name ABB Model Number MS116
Certification CE, CCC etc. Place of Origin China
High Light industrial type circuit breakermolded case circuit breaker

ABB MS116 Manual Motor Starters 3 Pole 0.1~32A 230/400V 440V Icu up to 50kA in compliance with IEC 60947

 

MS116 manual motor starters / Motor Protection Circuit Breaker

 

Description

Manual motor starters (MMS) are protection devices for the main circuit. They combine motor control and protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them and the installation fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds.

 

MS116 is a compact and economic range for motor protection up to 15.5 kW (400 V) / 32 A in width of 45 mm. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, threephase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

 

 

General Information

  • Extended Product Type:

    MS116-6.3

  • Product ID:

    1SAM250000R1009

  • EAN:

    4013614320323

  • Catalog Description:

    MS116-6.3 Manual Motor Starter

  • Long Description:

    The MS116-6.3 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 6.3 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

    Technical

  • Rated Service Short-Circuit Breaking Capacity (Ics):

    (230 V AC) 50 kA
    (400 V AC) 50 kA
    (440 V AC) 6 kA
    (500 V AC) 6 kA
    (690 V AC) 2 kA

  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):

    (230 V AC) 50 kA
    (400 V AC) 50 kA
    (440 V AC) 18 kA
    (500 V AC) 10 kA
    (690 V AC) 3 kA

  • Rated Instantaneous Short-Circuit Current Setting (Ii):

    78.8 A

  • Setting Range:

    4.0 ... 6.3 A

  • Rated Operational Power AC-3 (Pe):

    (400 V) Three Phase 2.2 kW

  • Rated Operational Voltage:

    Main Circuit 690 V AC

  • Rated Operational Current (Ie):

    6.3 A

  • Rated Operational Current AC-3 (Ie):

    6.3 A

  • Rated Frequency (f):

    Main Circuit 50 Hz
    Main Circuit 60 Hz

  • Rated Impulse Withstand Voltage (Uimp):

    Main Circuit 6 kV

  • Rated Insulation Voltage (Ui):

    690 V

  • Power Loss:

    at Rated Operating Conditions per Pole 0.7 ... 1.8 W

  • Number of Poles:

    3

  • Conventional Free-air Thermal Current (Ith):

    Main Circuit 6.3 A

  • Degree of Protection:

    Housing IP20
    Main Circuit Terminals IP10

  • Pollution Degree:

    3

  • Electrical Durability:

    100000 cycle

  • Mechanical Durability:

    100000 cycle

  • Terminal Type:

    Screw Terminals

  • Connecting Capacity Main Circuit:

    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible 1/2x 0.75 ... 2.5 mm²
    Rigid 1/2x 1 ... 4 mm²

  • Tightening Torque:

    Main Circuit 0.8 ... 1.2 N·m

  • Wire Stripping Length:

    Main Circuit 9 mm

  • Recommended Screw Driver:

    Pozidriv 2

  • Mounting Position:

    Position 1 to 6

  • Mounting on DIN Rail:

    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

  • Minimum Mounting Distance:

    Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
    Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
    Electrical Conductive Board, Vertical 75 mm
    Other Device Same Type, Horizontal 0 mm
    Other Device Same Type, Vertical 150 mm

  • Actuator Type:

    Rotary Handle

  • Contact Position Indication:

    ON / OFF

Standards:

IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company

  • Year Established:

    2013

  • Total Annual:

    5,000,000-6,000,000

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

Wuxi Fenigal Science and Technology Co. ,Ltd. is a high-tech enterprise specialized in reseach and developement of products on latest Electrical Distribution and Industrial Control & Automation, as well as special Lighting technology and products on Film & Media, Event, Industrial and Domest... Wuxi Fenigal Science and Technology Co. ,Ltd. is a high-tech enterprise specialized in reseach and developement of products on latest Electrical Distribution and Industrial Control & Automation, as well as special Lighting technology and products on Film & Media, Event, Industrial and Domest...

+ Read More

Get in touch with us

  • Reach Us
  • Wuxi Fenigal Science & Technology Co., Ltd.
  • 606#, Building-B, 100 Dicui Road, Binhu District, Wuxi, Jiangsu, China
  • https://www.lightingdistributionbox.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement