Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"LED Heat Sink Water Cooled Cold Plate Cooling Module Active Forced Air Solution","imgUrl":"https:\/\/img.chinax.com\/nimg\/79\/46\/3d9c223dd19e4e2bfc4bd4fe4b0a-200x200-1\/led_heat_sink_water_cooled_cold_plate_cooling_module_active_forced_air_solution.jpg","attrs":{"Product Dimension":"Can be customized","Corrosionresistance":"High, with protective coating","Bearing":"Alloy Bearing","Delivery Time":"5-7 days"}}
{"title":"DC5V 1504 Hydraulic Fan Cold Plates For Electronics Compact Cooling Solution","imgUrl":"https:\/\/img.chinax.com\/nimg\/b0\/81\/0dd410721b56dde006592f3bf57d-200x200-1\/dc5v_1504_hydraulic_fan_cold_plates_for_electronics_compact_cooling_solution.jpg","attrs":{"Supply Ability":"5000,000,000PCS Per Month","Delivery Time":"5-7 days","Place of Origin":"Dongguan\uff0cGuangdong,China","Minimum Order Quantity":"1000PCS"}}
{"title":"Precision Temperature Control Liquid Cold Plate Water Cooling Heat Dissipation","imgUrl":"https:\/\/img.chinax.com\/nimg\/d6\/68\/07965e00e5c59227a313187a66bc-200x200-1\/precision_temperature_control_liquid_cold_plate_water_cooling_heat_dissipation_system.jpg","attrs":{"Brand Name":"Uchi","Model Number":"Cold Plate","Minimum Order Quantity":"100pcs","Application":"Electronic Equipment,communication"}}
{"title":"S19-JPRO Computer Case Water Cooling Plate Manifold Aluminum Radiator Solution","imgUrl":"https:\/\/img.chinax.com\/nimg\/b1\/86\/e9bf5a901300a6818666b5a5a7a2-200x200-1\/s19_jpro_computer_case_water_cooling_plate_manifold_aluminum_radiator_solution.jpg","attrs":{"Material":"Aluminum + copper","Temper":"Polishing","fan life":"50000 Hrs","Water tap":"Outer diameter 9.5mm"}}
{"title":"Copper Aluminum Heat Sink Cold Plate Cooling System Water Thermal Solution","imgUrl":"https:\/\/img.chinax.com\/nimg\/de\/90\/de0a6d3068cd669388345f8ba5bc-200x200-1\/copper_aluminum_heat_sink_cold_plate_cooling_system_water_thermal_solution.jpg","attrs":{"Minimum Order Quantity":"100pcs","Supply Ability":"50000000pcs per Month","Bonding technology":"FSW, pressure pipe","Price":"Negotiable"}}
Application Scenarios: Electronic liquid cooling systems, high-power industrial power supplies, charging pile BMS, industrial control current sensing
Product Overview
This product is a customized Kelvin lead-type power shunt resistor featuring an integrated welding structure of high-conductivity copper alloy resistive element and electrolytic copper bracket.
Designed with low resistance, high current carrying capacity, and high-precision sampling capabilities, it is specifically engineered for industrial current sensing at hundreds of amperes, suitable for harsh high-temperature and high-vibration working conditions.
Welding: Bracket and copper alloy resistive element welded on non-sheared surfaces; no gaps, cold joints or false welds. Pickling before welding, passivation after welding.
Appearance: Flat, smooth and uniform surface; no burrs, burns, slag, contamination or cracks.
Encapsulation: Welded areas covered with transparent heat-shrink tube, tight and wrinkle-free. Leads firmly fixed, color coding clear.
Test & Acceptance Criteria
Factory Test: 100% inspection of resistance (200μΩ±3%), appearance and lead continuity; Factory Test Report issued.
Sampling Test: Per GB/T 2828.1-2012, sampling for withstand voltage, insulation and tensile strength, AQL=0.65.
Acceptance Documents: Factory test report, material certificate, RoHS/REACH compliance (upon request).
Packaging & Transportation
Packaging: Individually packed in anti-static bags, 50/100 pcs per box. Outer box labeled with model, quantity, date and batch number.
Transportation: Moisture-proof and anti-vibration packaging, avoid impact. Comply with RoHS and REACH for international logistics.
Core Functions
Flow Distribution / Collection: Distribute coolant from the main line evenly to multiple cold plates; collect heated fluid from each branch and return it to the cooling source / CDU after heat exchange.
Pressure & Resistance Management: Control pressure drop in each branch to prevent local overheating caused by uneven flow.
Simplified Piping & Maintenance: Reduce the number of connectors; with quick connectors, single cold plates can be rapidly installed or removed for maintenance.
Monitoring & Regulation (High-end Models): Integrated flow meters, temperature / pressure sensors, and even valves for fine-tuning flow in each branch.
Common Types & Structures
By Application
Manifold (Supply Side): 1 inlet, N outlets
Collector (Return Side): N inlets, 1 outlet; usually used in pairs
By Flow Division Method
Y-type / Tee Manifold: 1 inlet, 2 outlets; suitable for small systems with two cold plates
Bar / Row Manifold: 1 inlet, multiple outlets (e.g., 1-to-4, 1-to-6); commonly used in data centers / mining rigs
Annular Manifold: For closed-loop liquid cooling circuits
By Adjustability
Fixed Type: No valves, low cost; flow determined by orifice / channel design
Adjustable Type: Each branch equipped with needle / ball valves; flow adjustable manually or electrically
Material & Interface
Materials
Aluminum alloy: lightweight, moderate cost
Stainless steel: high pressure resistance, good corrosion resistance
Copper: excellent thermal conductivity but high cost
Must be compatible with system coolant to prevent corrosion
Interfaces
PC water cooling: commonly G1/4" thread
Industrial / data center: flanges, compression fittings, quick connectors (e.g., DME, ISO 8434)
Sealing
Must use O-rings / gaskets to prevent leakage; recommended materials: Nitrile Rubber (NBR) or Fluororubber (FKM)
Key Selection Parameters
Number of Branches & Flow Demand: Ensure sufficient flow for each cold plate to meet cooling requirements and avoid excessive pressure drop
Working Pressure / Temperature: Industrial cold plates typically operate at 0.3-1 MPa, 30-50°C
Install manifold in an easily accessible and observable location
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2006
Total Annual:
10000000-20000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Dongguan Uchi Electronics Co., Ltd. is a professional manufacturer specializing in the R&D, production and sales of water cooling plates and liquid cooling plates, focusing on the thermal dissipation industry.
With sophisticated production technology, precision processing equipmen...
Dongguan Uchi Electronics Co., Ltd. is a professional manufacturer specializing in the R&D, production and sales of water cooling plates and liquid cooling plates, focusing on the thermal dissipation industry.
With sophisticated production technology, precision processing equipmen...