| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Supply Ability | 5000-10000 pieces/month |
| Delivery Time | 7-15 days |
| Packaging Details | Box |
| Nominal Operating Voltage (Un) | 220Vac(50Hz) |
| Maximum Continuous Operating Voltage (Uc) | 320Vac(50Hz) |
| Nominal Discharge Current (In) | 20kA/ 40kA |
| Maximum Discharge Current (Imax) | 40kA/ 80kA |
| Voltage Protection Level (Up) | ≤1.25kV (L123-N)、≤1.8kV (L123-E)、≤650V (N-E) |
| Response Time | ≤25ns |
| Brand Name | LLH |
| Model Number | SLV-40T |
| Place of Origin | Guangdong Province, China |
View Detail Information
Explore similar products
Distribution Cabinet Fire Protection Equipment Fire Extinguisher Electricity Box
Whole Home Lightning Protection Low Voltage Surge Suppressor 220V 320V 20kA 40kA
Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device
Whole House Surge Suppression 220V 10kA 25kA Low Residual Voltage Protection
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 5000-10000 pieces/month |
| Delivery Time | 7-15 days | Packaging Details | Box |
| Nominal Operating Voltage (Un) | 220Vac(50Hz) | Maximum Continuous Operating Voltage (Uc) | 320Vac(50Hz) |
| Nominal Discharge Current (In) | 20kA/ 40kA | Maximum Discharge Current (Imax) | 40kA/ 80kA |
| Voltage Protection Level (Up) | ≤1.25kV (L123-N)、≤1.8kV (L123-E)、≤650V (N-E) | Response Time | ≤25ns |
| Brand Name | LLH | Model Number | SLV-40T |
| Place of Origin | Guangdong Province, China | ||
| High Light | Surge Protection Device 40kA ,T2 Surge Protective Device ,3 Phase AC Spd Device | ||
| Product features |
|
● Full mode protection
|
|
● No leakage current, no afterflow
|
|
● Large flow capacity and super low residual pressure
|
|
● Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection devices in three-phase power supply systems.
|
Product Specification
![]()
| Standards | IEC 61643.11 |
| SPD type | T2,T3 |
| Models |
SLV-40T SLV-80T |
| Nominal operating voltage Un | 220Vac(50Hz) |
| Maximum continuous operating voltage Uc | 320Vac(50Hz) |
| Nominal discharge current (8/20μs) In | 20kA/40kA |
| Maximum discharge current (8/20μs) Imax | 40kA/80kA |
| Voltage protection level In@Up | ≤1.25kV/≤1.8kV |
| L123-N,L123-E,N-E(3kA&6kV) Uoc | ≤650V |
| Response time tA | ≤25ns |
| Protection Circuit | L1,L2,L3-N,L1,L2,L3-E,N-E |
| Counting current range | 0.5kA(8/20μs)-80kA(8/20μs) |
| Counting digit | 0-999 |
Mechanical parameters
| Installation method | 4 fixed holes, DIN Rail 35mm |
| Screw torque | 5N*m |
| Strip length | 12mm |
| Wiring cross-sectional area | 2.5mm²-10mm² |
| Product size |
SLV-40T:178mmx116mmx75mm SLV-80T:197mmx139mmx90mm |
| Shell material and surface technology | Cold rolled steel plate painted black |
| Deterioration indication | LED green: OK; Off: Fail |
| Remote signaling contact type | Normally closed and normally open switching contacts |
| Remote signaling contact switching ability | 125 Vac / 1 A, 125 Vdc A / 0.2 |
| Maximum connection capacity of remote signaling | 2.5mm² |
| Installation position | Indoor |
| Degrees of protection provided by enclosure | IP20 |
| Temperature range | -40℃…+80℃ |
| Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
1.Install the SPD in LPZ 1-2 or subsequent lightning protection zones, ensuring the distance to protected equipment does not exceed 10 meters.
2.Use wiring with cross-sectional area 2.5mm²-10mm² and tighten screws to 5N·m torque for secure connections.
3.Ensure reliable grounding with a ground resistance ≤4Ω to guarantee surge current diversion efficiency.
4.Replace the SPD immediately if the LED indicator turns off (failed status) or after experiencing a severe surge impact.
5.Do not disassemble the product by yourself; improper operation may damage internal components and cause safety risks.
6.Avoid using the product in environments beyond the specified temperature (-40℃~+80℃) and humidity range
FAQ
Q1: What is the difference between SLV-40T and SLV-80T?
A1: The core difference is nominal discharge current (In) and maximum discharge current (Imax): SLV-40T has In=20kA/Imax=40kA, while SLV-80T has In=40kA/Imax=80kA. Other performance parameters and structural design are consistent.
Q2: Can this SPD be used for single-phase power systems?
A2: No, SLV-40T/SLV-80T is specifically designed for three-phase systems. For single-phase applications, choose SLV-40S/SLV-80S series products.
Q3: What is the function of remote signaling contacts?
A3: The normally closed and normally open switching contacts allow connection to monitoring systems, enabling remote alerts when the SPD fails.
Q4: Does the product require regular maintenance?
A4: Regular visual inspection is recommended (quarterly): check LED status and wiring tightness. No additional maintenance is needed under normal operating conditions.
Q5: Is the SPD compatible with different grounding systems?
A5: Yes, it is compatible with TN, TT, and IT grounding systems, as long as the grounding resistance meets the requirement (≤4Ω).
Company Details
Business Type:
Manufacturer
Year Established:
2018
Total Annual:
1000000-10000000
Employee Number:
20~100
Ecer Certification:
Verified Supplier
Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer... Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer...
Get in touch with us
Leave a Message, we will call you back quickly!