| SPD Type | T2、T3 (IEC 61643.11) |
| Nominal Operating Voltage (Un) | 220Vac(50Hz) |
| Maximum Continuous Operating Voltage (Uc) | 320Vac(50Hz) |
| Maximum Discharge Current (Imax) | 10kA /20kA |
| Voltage Protection Level (Up) | ≤1.25kV/≤1.5kV |
| Load Current | 10A (all models) |
| Brand Name | LLH |
| Model Number | LPF-10-320 |
| Place of Origin | Guangdong Province.China |
View Detail Information
Explore similar products
Nylon Surge Protection Devices Spds LED SPD 220V 5kA 10kA IP67 Outdoor Lightning
Outdoor Led Surge Protection Device 220V 320V 10kA 20kA IP67 T2 T3 SPD
Outdoor Industrial Lighting Protection LED Spd Surge Protection Device 220V 5kA
Outdoor Led Lighting Spd 220V 5kA 10kA AC DC Surge Protection Device IP67 T2 T3
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 5000-10000 pieces/mouth |
| Delivery Time | 7-15 days | Packaging Details | box |
| SPD Type | T2、T3 (IEC 61643.11) | Nominal Operating Voltage (Un) | 220Vac(50Hz) |
| Maximum Continuous Operating Voltage (Uc) | 320Vac(50Hz) | Maximum Discharge Current (Imax) | 10kA /20kA |
| Voltage Protection Level (Up) | ≤1.25kV/≤1.5kV | Load Current | 10A (all models) |
| Brand Name | LLH | Model Number | LPF-10-320 |
| Place of Origin | Guangdong Province.China | ||
| High Light | Street Light Led Spd ,Spd Surge Protector IP67 ,T2 Lightning Arrester Device | ||
| Product Features |
● Two ports, full mode protection |
●Small size and easy installation |
●Protection level up to IP67 |
●Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, installed in series at the front end of the final level equipment of the AC/DC power supply system, widely used as lightning protectors for LED street lights, sensors, and other equipment. |
Product Specification
![]()
Standards | IEC 61643-11 | |
SPD type | T2,T3 | |
Models | LPC 5-320 | LPC-10-320 |
Electrical parameters | ||
Nominal operating voltage Un | 220Vac(50Hz) | |
Maximum continuous operating voltage Uc | 320Vac(50Hz) | |
Nominal discharge current (8/20μs)In | 5kA | 10kA |
Maximum discharge current (8/20μs) Imax | 10kA | 20kA |
Voltage protection level In@Up | ≤1.25kV | ≤1.5kV |
Load current | 10A | 10A |
Response time tA | ≤25ns | ≤25ns |
Protection Circuit | L-N,L-E,N-E | L-N,L-E,N-E |
Failure and alarm | ||
Deterioration indication | LED green: OK; Off: Fail (optional function) | |
Fixed method | φ4mmFixing lug |
Wire length | 200mm |
Wire cross-sectional area | 1.5mm² |
Product size | 42mmx30mmx23mm |
Shell material and flame retardant grade | Nylon,VO |
Installation position | Indoor and outdoor |
Degrees of protection provided by enclosure | IP67 |
Temperature range | -40℃…+80℃ |
Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
1.Installation Scenario: Designed for series installation at the front end of LED street lights and high-power outdoor equipment, within LPZ 2-3 or subsequent lightning protection zones.
2.Secure Mounting: Use the included φ4mm fixing lugs for stable installation, ensuring resistance to wind and vibration in outdoor environments.
3.Wiring & Sealing: Utilize the pre-attached 200mm wires (1.5mm² cross-sectional area) for convenient wiring; ensure proper sealing of all connections to maintain IP67 protection.
4.Load Limit: Do not exceed the maximum 10A load current to prevent overheating and ensure device longevity.
5.Status Monitoring: If the optional green LED indicator is off (indicating device failure) or after severe surge impact, replace the SPD immediately to maintain continuous protection.
6.System Compatibility: This product is designed for AC 220Vac(50Hz) systems; always confirm the system voltage matches before installation.
FAQ
Q1: What is the maximum load current rating of the LPC Series?
A1: The LPC Series supports a maximum load current of 10A, making it ideal for high-power LED street lights and other outdoor equipment with moderate power requirements.
Q2: How does the LPC Series differ from the LPF Series?
A2: The LPC Series features a two-port design and 10A load current capacity, specifically engineered for high-power outdoor equipment. In contrast, the LPF Series uses a one-port design without a specified load current limit, intended for general-purpose equipment applications.
Q3: Is this product suitable for high-humidity coastal areas?
A3: Yes. Its IP67 ingress protection and corrosion-resistant nylon housing make it highly suitable for high-humidity and corrosive coastal environments.
Q4: Can this SPD be used for other outdoor equipment besides LED street lights?
A4: Absolutely. It is compatible with a wide range of high-power outdoor electronic devices, including large-scale sensors, outdoor monitoring equipment, and other industrial outdoor units.
Q5: What are the specifications of the pre-attached wires?
A5: The product comes with 200mm-long wires with a cross-sectional area of 1.5mm², designed for convenient and reliable field wiring.
Company Details
Business Type:
Manufacturer
Year Established:
2018
Total Annual:
1000000-10000000
Employee Number:
20~100
Ecer Certification:
Verified Supplier
Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer... Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer...
Get in touch with us
Leave a Message, we will call you back quickly!