| SPD Type | T2 (IEC 61643.11) |
| Nominal Operating Voltage (Un) | 300Vdc/500Vdc/1000Vdc/1500Vdc |
| Maximum Continuous Operating Voltage (Uc) | 400Vdc/600Vdc/1100Vdc/1600Vdc |
| Nominal Discharge Current (In) | 20kA |
| Maximum Discharge Current (Imax) | 40kA |
| Response Time | ≤25ns |
| Brand Name | LLH |
| Model Number | LPM PV300 |
| Place of Origin | Guangdong Province.China |
View Detail Information
Explore similar products
Whole House Surge Protector 3 Phase 220V 30kA 65kA Office Building Power
Electrical SPD T2 AC SPD 3 Phase 220V 385V 30kA 65kA For Home Use
Surge Voltage Arrester 3 Phase 220V 385V 40kA 80kA Home Lightning Surge
Type 2 Surge Protection Device 3 Phase 220V 385V 40kA 80kA For Electrical Panel
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 5000-10000 pieces/mouth |
| Delivery Time | 7-15 days | Packaging Details | box |
| SPD Type | T2 (IEC 61643.11) | Nominal Operating Voltage (Un) | 300Vdc/500Vdc/1000Vdc/1500Vdc |
| Maximum Continuous Operating Voltage (Uc) | 400Vdc/600Vdc/1100Vdc/1600Vdc | Nominal Discharge Current (In) | 20kA |
| Maximum Discharge Current (Imax) | 40kA | Response Time | ≤25ns |
| Brand Name | LLH | Model Number | LPM PV300 |
| Place of Origin | Guangdong Province.China | ||
| High Light | Dc Surge Protector 300V ,Dc Surge Protector 1500V ,T2 PV DC Surge Protection Device | ||
Fault resistant Y-type circuit design Integrated with an arc extinguishing baffle, it prevents fire hazards caused by internal arcs, improving system safety. | Double pluggable and anti-vibration design The hot-swappable module can be replaced without power interruption, with anti-vibration structure ensuring stable operation in industrial environments. | 35MM Din rail The hot-swappable module can be replaced without power interruption, with anti-vibration structure ensuring stable operation in industrial environments. | Remote signaling monitoring Supports normally open/closed contacts for real-time fault alerts, enabling remote status monitoring and reducing on-site inspection costs. |
![]()
![]()
Standards | IEC 61643-11 | |||
SPD type | T2 | |||
Models | LPM PV300 | LPM PV500 | LPM PV1000 | LPM PV1500 |
Electrical parameters | ||||
Nominal operating voltage Un | 300Vdc | 500Vdc | 1000Vdc | 1500Vdc |
Maximum continuous operating voltage Uc | 400Vdc | 600Vdc | 1100Vdc | 1600Vdc |
Nominal discharge current (8/20μs)In | 20kA | |||
Maximum discharge current (8/20μs) Imax | 40kA | |||
Voltage protection level In@Up | ≤1.2kV | ≤1.8kV | ≤3.6kV | ≤4.5kV |
Response time tA | ≤25ns | |||
Protection Circuit | +/-,+/E,-/E | |||
Mechanical parameters
| Installation method | DIN Rail 35mm |
| Screw torque | 5N*m |
| Strip length | 12mm |
| Wiring cross-sectional area | 2.5mm²-32mm² |
| Product size | 90mmx54mmx68mm |
| Shell material and flame retardant grade | Mineral nylon PA6, V0 |
| Deterioration indication | Window green: OK; Window red: Fail |
| Remote signaling contact type | Normally closed and normally open switching contacts |
| Remote signaling contact switching ability | 125Vac/1A,125Vdc/0.2A |
| Maximum connection capacity of remote signaling | 2.5mm² |
| Installation position | Indoor |
| Degrees of protection provided by enclosure | IP20 |
| Temperature range | -40℃…+80℃ |
| Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
● Select the appropriate model based on the PV system's DC voltage (75Vdc~900Vdc).
● Use wiring with cross-sectional area 2.5mm²-32mm² and tighten screws to 5N·m torque.
● Install the SPD in the DC side of the PV system, close to the protected equipment.
● Ensure reliable grounding with ground resistance ≤4Ω to guarantee surge diversion efficiency.
● Regularly check the status window—replace the module immediately if it turns red (failure status).
● The product is for indoor use; avoid outdoor exposure to moisture and direct sunlight.
FAQ
Q1: What is the difference between LPM PV series and LPM PD series?
A1: LPM PV series supports higher DC voltages (up to 1500Vdc) for large-scale PV systems, while LPM PD series is for low to medium-voltage (75Vdc~900Vdc) PV applications.
Q2: Can this SPD be used for 12Vdc or 24Vdc solar systems?
A2: Yes, the LPM PD100 model (75Vdc Un) is compatible with 12Vdc/24Vdc solar systems, providing overvoltage protection.
Q3: Does the product have a built-in arc extinguishing mechanism?
A3: Yes, it is equipped with a built-in rotary arc extinguishing baffle to prevent arc faults during surge protection.
Q4: What is the installation method for this product?
A4: It adopts 35mm standard DIN Rail mounting, compatible with most PV combiner boxes and electrical cabinets.
Q5: What is the service life of the LPM PD series?
A5: Under normal operating conditions, the service life is 5-8 years. It may vary based on surge frequency and environmental factors.
Company Details
Business Type:
Manufacturer
Year Established:
2018
Total Annual:
1000000-10000000
Employee Number:
20~100
Ecer Certification:
Verified Supplier
Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer... Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer...
Get in touch with us
Leave a Message, we will call you back quickly!