Payment Terms | T/T, Western Union, MoneyGram |
Supply Ability | 300 kits per day |
Delivery Time | 3 working days |
Packaging Details | By foam box with ice bag to maintain cool storage |
Sample performance | milk and goat's milk |
Packing | 96 tests/kit |
Shelf life | 12 months when properly stored |
Brand Name | GreenSpring |
Model Number | LSY-20040 |
Certification | ISO9000 |
Place of Origin | China |
View Detail Information
Explore similar products
Melamine rapid test strip (for milk and fresh milk)50ppb
Antibiotic Residues Rapid Test Device Tetracycline Lateral Flow Rapid Test Kit
LSY-20003 Veterinary Drug Residues Lateral Flow Device Test Kit Melamine Rapid
Lincomycin rapid test strip
Product Specification
Payment Terms | T/T, Western Union, MoneyGram | Supply Ability | 300 kits per day |
Delivery Time | 3 working days | Packaging Details | By foam box with ice bag to maintain cool storage |
Sample performance | milk and goat's milk | Packing | 96 tests/kit |
Shelf life | 12 months when properly stored | Brand Name | GreenSpring |
Model Number | LSY-20040 | Certification | ISO9000 |
Place of Origin | China |
Sulfonamides residues (SAs) rapid test strip (milk)
Catalog No. LSY-20040
1. Specifications: 8 dipsticks/bottle, 12 bottles/box
2. Brief
This product is used for testing Sulfonamides residue in milk sample(pure milk and fresh milk) and goat’s milk qualitatively, the whole test procedure only need 6min, easy to operate with high sensitivity.
3. Detection limit in milk [ppb(ug/kg)]
Name | Detection limit | Name | Detection limit |
Sulfadiazine (SD or SDZ) | 1-3 | Sulfafurazole(SIZ) | 30-40 |
Sulfamerazine (SM1) | 1-3 | Sulfamethoxypyridazine (SMPZ) | 20-25 |
Sulfamonomethoxine (SMM) | 1-3 | Sulfachloropyridazine (SCPA) | 10-15 |
Sulfadimethoxypyrimidine | 1-3 | Sulfapyridine | 50-60 |
Sulfathiazole(ST) | 5-6 | Sulfadimoxine (SDM2) | 20-30 |
Sulfamethoxypyridazine (SMP) | 6-10 | Sulfacetamide | 50-60 |
Sulfaquinoxaline(SQX) | 20-25 | Sulfapyrazole | 50-60 |
Sulfamethoxazole (SMZ) | 10-15 | Sulfadimethoxine | 5-10 |
Sulfamethazine(SM2) | 5-8 | Sulfapyridine(SPD) | 20-40 |
Sulfamethoxydiazine(SMD) | 1-3 | Sulfaphenazolum(SPP) | 20-40 |
4. Principle
The Sulfonamides rapid test dipstick is based on competitive inhibition immuno-chromatographic principle. In the flow process, Sulfonamides in the sample combined with Sulfonamides specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Sulfonamides -BSA conjugate on Test line of NC membrane, lead to the color change of Test line.
When the sample has no Sulfonamides residue or concentration lower than detection limit, T line is darker than C line. when the concentration is equal to or higher than detection limit, T line is lighter than C line obviously or T line is invisible or T line has same color with C line. No matter whether there is Sulfonamides residue in sample, C line will appear, it means the test is valid.
5. Contents
1 | Sulfonamides test dipsticks | 8 strips/bottle, 12 bottles |
2 | Red powder micro-wells | 8 micro-wells/bottle, 12 bottles |
3 | Manual | 1 piece |
4 | Desiccant | 2 piece/bottle |
6. Operation procedures
6.1 Read the instruction carefully before use. Return test dipsticks and sample into room temperature.
6.2 Take bottles needed from the kit package, take out required micro-wells and dipsticks, making proper marks. Please use these test dipsticks within 1h. Seal the cap of the bottles, avoid moisture.
6.3 Take 200ul of the test samples into the micro-wells, then repeatedly absorb for 5 times, mix the sample with the reagent in the micro-wells completely until no solid judge by eyes (this is a very important step).
6.4 Incubate for 3min at (40±2℃), insert the test dipsticks into the micro-wells with the "MAX" end fully dipped in to the mixture solution.
6.5 Insert the test dipsticks into the solution for 3min, read the result, it is invalid in other time.
7. Test Result Interpretation
Color depth comparison of T line and C line | Result judgment | Result analysis |
T line > C line | Negative | Sulfonamides residue is lower than detection limit in sample |
T line = C line | Weak positive | Sulfonamides residue is equal to detection limit in sample |
T line < C line or T line is invisible | Positive | Sulfonamides residue is higher than detection limit in sample |
C line is invisible | Invalid | The test dipstick is invalid, test again |
8. Precautions
1) The test dipsticks can be used only once at room temperature, do not use test dipsticks out of expiry date.
2) Please seal the bottle after taking out required test dipsticks. If can not use all 8 micro-wells at once, cup the rest and put it back to bottle and sealed.
3) Do not touch the white membrane surface in the middle of test dipsticks, avoid sunlight and fan blowing directly.
4) Milk samples should be fully liquid without any agglomeration, sour and precipitation.
5) Use the test dipsticks testing again for positive results.
6) Please contact the supplier for any questions.
7) The result is for reference only, for confirmation, please refer to the relevant national standard method.
9. Specificity
Test 500ppb Tetracyclines, Fluoroquinolone, theChloramphenicol etc. the result is Negative.
10. Storage and expiry date
Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.
Shenzhen Lvshiyuan Biotechnology Co., Ltd
D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China
Tel. 86-755-28438788
Fax 86-755-28938800
Email: info@lsybt.com
www.lsybt.com
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2003
Total Annual:
$100,000,000-$200,000,000
Employee Number:
200~500
Ecer Certification:
Site Member
Shenzhen Lvshiyuan Biotechnology Co.,Ltd(hereinafter referred to as LSY), was founded in 2003, located in the National Marine Biological Industrial Park (Dapeng New District, Shenzhen), with an area of more than 20000 square meters according to GMP standards. We have established five branches ... Shenzhen Lvshiyuan Biotechnology Co.,Ltd(hereinafter referred to as LSY), was founded in 2003, located in the National Marine Biological Industrial Park (Dapeng New District, Shenzhen), with an area of more than 20000 square meters according to GMP standards. We have established five branches ...
Get in touch with us