China Biological Research Dual Beam Spectrophotometer Inductively Coupled Plasma
China Biological Research Dual Beam Spectrophotometer Inductively Coupled Plasma

  1. China Biological Research Dual Beam Spectrophotometer Inductively Coupled Plasma

Biological Research Dual Beam Spectrophotometer Inductively Coupled Plasma

  1. MOQ: 1pcs
  2. Price: TALK ABOUT IT
  3. Get Latest Price
Payment Terms Western Union, MoneyGram, T/T, L/C
Supply Ability 5000pcs/m
Delivery Time within 5 days
Packaging Details PE film then Carton
Wavelength Range 190~1100nm
Band Width 1.8nm , 1.0nm,or 0.5 , 1, 2, 4nm adjustable
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability 0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.03% τ (220nm NaI,340nm NaNO2)
Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm
Baseline Flatness ± 0.001A
PHOTOMETRIC MODE T,A,C,E
WAVELENGTH SETTING AUTOMATIC
Brand Name macylab
Model Number UV-1700 UV-V Spectrophotometer
Certification all
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, MoneyGram, T/T, L/C Supply Ability 5000pcs/m
Delivery Time within 5 days Packaging Details PE film then Carton
Wavelength Range 190~1100nm Band Width 1.8nm , 1.0nm,or 0.5 , 1, 2, 4nm adjustable
Wavelength Accuracy ±0.3nm Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A) Photometric Repeatability 0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.03% τ (220nm NaI,340nm NaNO2) Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm Baseline Flatness ± 0.001A
PHOTOMETRIC MODE T,A,C,E WAVELENGTH SETTING AUTOMATIC
Brand Name macylab Model Number UV-1700 UV-V Spectrophotometer
Certification all Place of Origin China
High Light uv-1700 dual beam spectrophotometerbiological research dual beam spectrophotometerbiological double beam uv visible spectrophotometer

Product description, technical parameters and configuration

 

Character

 

●UV-1700PC successful implementation of the stringent requirements of high accuracy and reliability measurement to meet the requirements of various applications that can be used in biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

●A wide wavelength range, the wavelength range to meet the various requirements of the field

●5nm, 4nm, 2nm, 1nm, 0.5nm spectral bandwidth of five custom installation according to user requirements, to meet the stringent requirements of the Pharmacopoeia

●Automatic design to achieve the most simple means of measurement

●LSI design greatly improves the scalability and reliability of the system

●Improved optimization of the optical design, import source and receiver system created a high performance and high reliability

●Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three-wavelength (optional) DNA protein measurements (optional), and other measurement methods to meet different measurement requirements, and can be displayed directly on a 6-inch screen

●Based on user requirements optional hole rack, manual four with stand, manual Eighth rack, automatic Eighth frame, glass stand, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks

●Measurement data can be output through the printer with USB interface

●Can be powered down to save the measurement parameters and data, user-friendly

●Can achieve more accurate and flexible measurement via PC control, which can meet the needs of different users

 
Technical Specifications
 
 
Wavelength Range
190~1100nm
Band Width
1.8nm , 1.0nm,or 0.5 , 1, 2, 4nm adjustable
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.1nm
Photometric Accuracy
±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability
0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light
≤0.03% τ (220nm NaI,340nm NaNO2)
Stability
0.0005A/h@500nm
Noise
± 0.0002A @500nm
Baseline Flatness
± 0.001A
Photometric Mode
T,A,C,E
Wavelength Setting
Automatic
Photometric Display Range
-4~4A
Display Mode
6 inches high brightness blue LCD
Detector
Import Silicon Photodiode
Light Source
Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement
AC 220V/50Hz 110V/60Hz
Power
120W
Dimensions(W*D*H)
560×450×230mm
Weight
28Kg

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    3000000-5000000

  • Employee Number:

    20~50

  • Ecer Certification:

    Active Member

    Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in...     Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in...

+ Read More

Get in touch with us

  • Reach Us
  • Macylab Instruments Inc.
  • A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China
  • MsJane
  • 8601063014082
  • https://www.laboratoryspectrophotometer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement