Payment Terms | T/T, Western Union |
Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days |
Packaging Details | 1pc/pouch, 25pcs/box |
Method | Gold Colloidal |
Format | 5 Multiple panel |
Specimen | Urine |
Testing time | 5-15 minutes |
Shelf Life | 24 Months |
Application | 5 drugs |
Brand Name | New Life |
Model Number | Panel |
Certification | ISO13485, CE |
Place of Origin | China |
View Detail Information
Explore similar products
TML Urine Drug Abuse Test Kit Gold Colloidal 100ng/Ml Cut Off Qualitative
Professional Tramadol Test Kit Rapid Diagnostic Card Format 24 Month Shelf Life
Rapid Diagnostic Drug Abuse Test Kit , Urine Drug Screen Kits For Morphine
CE Approved Portable Drug Test Kits 4mm Dipcard 500ng/ML Cut - Off For Ecstasy
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 2000000pcs/month |
Delivery Time | 20-30days | Packaging Details | 1pc/pouch, 25pcs/box |
Method | Gold Colloidal | Format | 5 Multiple panel |
Specimen | Urine | Testing time | 5-15 minutes |
Shelf Life | 24 Months | Application | 5 drugs |
Brand Name | New Life | Model Number | Panel |
Certification | ISO13485, CE | Place of Origin | China |
High Light | self testing drug kits , accurate drug test kits |
MultiDrug of Abuse Rapid test,Urine Specimen, High Accuracy, Easily & Quick operation on spot, Gold colloidal method
Intended Use
The Multi-Drug Rapid Test Panel with Adulteration is a rapid chromatographic immunoassay for the detection of drugs and drug metabolites in urine at the following cut-off concentrations in urine:
Product | Cat No | Specimen | Sensitivity | Format | Kit Size |
Drugs of Abuse (DOA) Tests | |||||
AMP | YD101S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD101C4 | 4mm Cassette | 25T | |||
BAR | YD201S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD201C4 | 4mm Cassette | 25T | |||
BZO | YD301S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD301C4 | 4mm Cassette | 25T | |||
COC | YD401S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD401C4 | 4mm Cassette | 25T | |||
MOR(MOP) | YD501S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD501C4 | 4mm Cassette | 25T | |||
MET | YD601SM | Urine | 500 ng/mL | 3mm Strip | 100T |
YD601CM | 4mm Cassette | 25T | |||
MTD | YD701S3 | Urine | 300 ng/mL | 3mm Strip | 100T |
YD701C4 | 4mm Cassette | 25T | |||
MDMA | YD801S3 | Urine | 500 ng/mL | 3mm Strip | 100T |
YD801C4 | 4mm Cassette | 25T | |||
THC | YD901S3 | Urine | 50 ng/mL | 3mm Strip | 100T |
YD901C4 | 4mm Cassette | 25T | |||
BUP | YD111S3 | Urine | 100 ng/mL | 3mm Strip | 100T |
YD111C4 | 4mm Cassette | 25T | |||
PCP | YD121S3 | Urine | 25 ng/mL | 3mm Strip | 100T |
YD121C4 | 4mm Cassette | 25T | |||
K2 | YD131S3 | Urine | 200 ng/mL | 3mm Strip | 100T |
YD131C4 | 4mm Cassette | 25T | |||
OPI | YD141S3 | Urine | 2000 ng/mL | 3mm Strip | 100T |
YD141C4 | 4mm Cassette | 25T | |||
TCA | YD151S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD151C4 | 4mm Cassette | 25T | |||
KET | YD161S3 | Urine | 1000 ng/mL | 3mm Strip | 100T |
YD161C4 | 4mm Cassette | 25T | |||
TML | YD171S3 | Urine | 100 ng/mL | 3mm Strip | 100T |
YD171C4 | 4mm Cassette | 25T | |||
DOA 2-in-1 | YD021C5 | Urine | See Insert | 2-in-1 Panel | 25T |
DOA 3-in-1 | YD031C5 | Urine | See Insert | 3-in-1 Panel | 25T |
DOA 4-in-1 | YD041C5 | Urine | See Insert | 4-in-1 Panel | 25T |
DOA 5-in-1 | YD051C5 | Urine | See Insert | 5-in-1 Panel | 25T |
DOA 6-in-1 | YD061C5 | Urine | See Insert | 6-in-1 Panel | 25T |
DOA 7-in-1 | YD071C5 | Urine | See Insert | 7-in-1Panel | 25T |
DOA 8-in-1 | YD081C5 | Urine | See Insert | 8-in-1Panel | 25T |
DOA 9-in-1 | YD091C5 | Urine | See Insert | 9-in-1 Panel | 25T |
DOA 10-in-1 | YD011C5 | Urine | See Insert | 10-in-1 Panel | 25T |
Alcohol | YD151C5 | Saliva | See Insert | Strip | 100T |
DIRECTIONS FOR USE
Allow the test, urine specimen, and/or controls to reach room temperature
(15-30ºC) prior to testing.
Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
Remove the cap.
With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the dipstick to at least the level of the wavy lines, but not above the arrow on the test panel.
Replace the cap and place the test panel on a non-absorbent flat surface.
Start the timer and wait for the colored line(s) to appear.
The result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.
*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.
POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.
INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.
QUALITY CONTROL
A procedural control is included in the test. A line appearing in the control region
(C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.
Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.
ORIENT NEW LIFE MEDICAL CO., LTD. | |
Contact: | Jerry Meng |
Email: | Jerry @ newlifebiotest .com |
Tel. | +86 18657312116 |
SKYPE | enetjerry |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
10,000,000-15,000,000
Employee Number:
200~300
Ecer Certification:
Active Member
Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti... Established in 2009, Orient New Life Medical Co., Ltd., is specialized in high-tech biological diagnostic test development, research and production, as well as high-tech medical device development, research and production. New Life has built up two production base, which produce biological diagnosti...
Get in touch with us
Leave a Message, we will call you back quickly!