  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Packaging Details Wooden case
Type Blood Testing Equipments
Name BSC Biosafety Cabinet
Overall size 1500×800×2120mm
Purification area size 1300×700×600mm
Product name Biosafety cabinet
Model BSC-1300B2
Downflow velocity 0.31±0.025m/s
Inflow velocity 0.48±0.025m/s
Brand Name HAIYING
Model Number BSC-1300B2
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Packaging Details Wooden case
Type Blood Testing Equipments Name BSC Biosafety Cabinet
Overall size 1500×800×2120mm Purification area size 1300×700×600mm
Product name Biosafety cabinet Model BSC-1300B2
Downflow velocity 0.31±0.025m/s Inflow velocity 0.48±0.025m/s
Brand Name HAIYING Model Number BSC-1300B2
Certification CE Place of Origin CHINA
High Light ULPA Biological Safety CabinetHAIYING BSC Biological Safety CabinetHAIYING biosafety cabinet class 2 b2

Premium ULPA Filter HD LED Display BSC Biological Safety Cabinet

BSC Biosafety Cabinet Features:
1.  The biological safety cabinet has four negative pressures, namely: the left and right sides of the entire device, the rear, and the bottom wall are all negative pressure air ducts, so that the working area and the external environment form a double working air curtain and the cabinet to maintain the isolation. The area is surrounded by negative pressure to ensure that the sample does not leak.
2.  The cabinet body part adopts 1.5mm thick cold-rolled steel plate to enhance the structural strength. The surface of the cabinet body is electrostatically sprayed to make the whole device more stable.
3.  The control panel adopts light touch switch, humanized design, beautiful appearance of the machine and convenient operation.
4.  The working area inside the workbench and the equipment is high-quality 304# stainless steel, which is corrosion-resistant.
5.  Ultra high efficiency filter for particles, smoke and microorganisms in the air filter. Various types of biological safety cabinets use imported ultra-high efficiency filters (ULPA) with a filtration efficiency of over 99.995% (0.1-0.2μmDOP), and the cleanliness of the working space can reach 100. Equipped with a dual-channel digital pressure monitoring and electronic alarm system, real-time dynamic monitoring of the pressure loss of exhaust and air filters, downward flow and inflow air flow in the working area, two-way detection,
6.  The opening height of the safety cabinet window exceeds the height specified by the front window operation port, sound and light alarms, and the interlock system is activated. When the opening height returns to the specified opening height, the alarm interlock system will automatically release.

 

Model BSC-1300B2
Clean Grade HEPA:ISO 5 calss ( Class100 )
ULPA:ISO 4 Class ( Class10 )
HEPA Filter HEPA:≥99.995% , @0.3μm
ULPA:≥99.999% , @0.12μm
Air tightness 99.99≤E≤99.999
Overall Dimensions 1500×800×2120mm
Working Space 1300×700×600
mm
Downflow Velocity 0.35m/s
Forward intake wind speed 0.25m/s±0.025m/s

 

Installation of BSC Biosafety Cabinet:

1.  The biological safety cabinet shall not be placed on its side, impacted, or collided during transportation, and shall not be directly attacked by rain, snow, or sun exposure.

2.  The working environment of the biological safety cabinet is 10~30℃ and the relative humidity is <75%.

3.  The equipment should be installed on a horizontal surface that cannot be moved.

4.  The equipment must be installed close to a fixed power socket.

5.  In order to prevent airflow interference, it is required that the equipment should not be installed in the passages of people, and the operating port of the sliding front window of the biological safety cabinet should not be directly facing the doors and windows of the laboratory or too close to the doors and windows. Places that may disturb the airflow.

 

Company Introduction:

Shandong Haiying Wuzhou Instrument Co., Ltd.

We have 15 years of experience in the operation of laboratory equipment, medical inspection and testing equipment, a mature business team, and a perfect service system. Our company adheres to the business philosophy of "Haina, Baichuan and Dadao win-win"

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Trading Company

  • Year Established:

    2016

  • Total Annual:

    1800000-2000000

  • Employee Number:

    80~90

  • Ecer Certification:

    Active Member

The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality... The company uses the business philosophy that is fully integrated with the market economy and efficient management and operation mechanism, takes the market as the guide, and builds a "customer-centric" marketing system based on customer needs. Ensure to provide customers with high-quality...

+ Read More

Get in touch with us

  • Reach Us
  • Shandong Haiying Wuzhou Instrument Co., Ltd.
  • Room 309, Huineng Building, 38 Huaneng Road
  • https://www.medicallabmachine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement