Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Industrial Automation Metal Electrical PLC Control Cabinet For Inverter","imgUrl":"https:\/\/img.chinax.com\/nimg\/24\/97\/d1eb3fd983ecebf169c121c42449-200x200-1\/industrial_automation_metal_electrical_plc_control_cabinet_for_inverter.jpg","attrs":{"Model Number":"JL84165465","Certification":"ISO9001\uff0cCE","Place of Origin":"China","Minimum Order Quantity":"5"}}
{"title":"Building Automation Control BAS Control Panel 1.5mm Thickness For Blinds","imgUrl":"https:\/\/img.chinax.com\/nimg\/b0\/a1\/dc7467f25dbb2463b28ae3fd5a3c-200x200-1\/building_automation_control_bas_control_panel_1_5mm_thickness_for_blinds_sunshades.jpg","attrs":{"Model Number":"JL8416515633","Certification":"ISO9001\uff0c3C","Place of Origin":"China","Minimum Order Quantity":"20"}}
{"title":"Custom Industrial PLC Control Panel with Integrated HMI Touchscreen","imgUrl":"https:\/\/img.chinax.com\/nimg\/e3\/6c\/e0b8dc1af0f7821e82211356562c-200x200-1\/custom_industrial_plc_control_panel_with_integrated_hmi_touchscreen.jpg","attrs":{"Certification":"CE RoHS","Place of Origin":"China","Minimum Order Quantity":"1","Payment Terms":"T\/T,Western Union"}}
{"title":"Networked PLC System Cabinet Supporting Profinet and Modbus TCP","imgUrl":"https:\/\/img.chinax.com\/nimg\/ed\/49\/bac05001c626881040ac5666b208-200x200-1\/networked_plc_system_cabinet_supporting_profinet_and_modbus_tcp.jpg","attrs":{"Certification":"CE","Place of Origin":"China","Minimum Order Quantity":"1","Payment Terms":"Western Union,T\/T"}}
{"title":"Air Conditioning Constant Temperature & Humidity PLC Control Cabinet Corrosion","imgUrl":"https:\/\/img.chinax.com\/nimg\/35\/10\/3a19c74b068f0817ca71e6c8edd7-200x200-1\/air_conditioning_constant_temperature_26_humidity_plc_control_cabinet_corrosion_resistant.jpg","attrs":{"Model Number":"KL564165","Certification":"ISO9001\/CE","Place of Origin":"China","Minimum Order Quantity":"5"}}
{"title":"Floor-Standing Single-Door PLC Control Cabinet (Chemical Plant \/ Factory Use)","imgUrl":"https:\/\/img.chinax.com\/nimg\/90\/b3\/07a7a135121f642436df7ea3aac9-200x200-1\/floor_standing_single_door_plc_control_cabinet_28chemical_plant_2f_factory_use_29.jpg","attrs":{"Brand Name":"HMD","Model Number":"264515145415","Certification":"CE","Place of Origin":"China"}}
{"title":"Cold-rolled steel Small Commercial Building Visual PLC Cabinet HVAC & Lighting &","imgUrl":"https:\/\/img.chinax.com\/nimg\/cf\/fe\/71b7cbd3c2fc316ba60a5edeba7c-200x200-1\/cold_rolled_steel_small_commercial_building_visual_plc_cabinet_hvac_26_lighting_26_pump_control.jpg","attrs":{"Brand Name":"HMD","Model Number":"4512556422","Certification":"CE","Place of Origin":"China"}}
Industrial Automation PLC Control Cabinet Inverter Ventilation System
Product Describe:
1. Precise speed regulation and energy saving: The frequency converter achieves stepless speed regulation of the motor through frequency adjustment, avoiding energy waste caused by "big horses pulling small cars" (especially suitable for variable load scenarios such as fans and water pumps, with an energy saving rate of up to 20% -50%). 2. Automation and Intelligence: PLC can write complex logic programs to achieve automatic start stop, dynamic adjustment based on sensor data (such as automatic adjustment of pump speed according to pipeline pressure in constant pressure water supply systems), automatic fault alarm and other functions, reducing manual intervention. 3. Safety and reliability: Integrated with multiple protection functions, it can prevent motor overload, short circuit, and overvoltage. At the same time, the structural design of the control cabinet (such as heat dissipation and dust prevention) ensures stable operation of the equipment in industrial environments.
Specification:
Type
Dimension Range (Height × Width × Depth, unit: mm)
Description
Common Sizes
Small: 1200×600×400
Suitable for simple control systems with few components, such as small water pump or fan control.
Medium: 2200×800×600, 2200×800×800
Ideal for medium-sized systems, capable of accommodating inverters, PLCs, and more auxiliary components (e.g., sensor interfaces, relays).
Large: 2200×1600×800
Used in complex industrial scenarios, supporting linkage control of multiple devices with sufficient internal expansion space.
Height: 1800-2200
Can be adjusted according to installation space (e.g., machine room size, wall-mounted/floor-standing requirements) and the number of components.
Width: 600, 800, 1000
Depth: 400-800
Examples of Special Specifications
600×1200×350, 1500×700×400, 1700×700×400
Designed for specific scenarios (e.g., installation in compact spaces, matching with dedicated equipment).
Ensure inverter power is 10-20% higher than the motor’s, with 15-20% extra capacity for multi-device setups.
Choose basic PLCs for simple control (e.g., single pump) or advanced models with analog/communication modules for complex logic (e.g., remote monitoring).
2. Fit structure and environment
Opt for floor-mounted cabinets (≥1800mm height) for large systems, or wall-mounted (≤1200mm) for small setups, checking weight capacity.
Use IP54+ enclosures for dusty/damp areas; add explosion-proof features for hazardous zones.
3. Add functional extras
Include a 7-10 inch touchscreen for parameter adjustments; integrate 4G/Ethernet for remote access if needed.
Ensure overload/short-circuit protection; add temperature sensors for high-heat environments.
4. Optimize cooling and wiring
Use forced air cooling for inverters over 5.5kW; separate power and signal cables to avoid interference.
5. Balance cost and lead time
Prioritize standard components to cut costs. Allow 7-15 days for simple customizations, 30-45 days for complex ones (e.g., explosion-proof designs).