Supply Ability | 300/Year |
Payment Terms | L/C, T/T, D/P |
Model NO. | YC98S1 |
Warranty | 1 Year |
Voltage Output | 30V-480V |
Current Output | 0.05-10A |
Thermocouple (TC) | No |
Resistance-Temperature Detector (RTD) | No |
LCD Display | With LCD Display |
Customized | Customized |
Trademark | GENY |
Transport Package | Carton |
Specification | 1.5KG |
Origin | China |
HS Code | 9030849000 |
Port | Guangzhou, China |
Brand Name | GENY |
Model Number | YC89S1 |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High Precision Portable Reference Standard For Single Phase Meter Calibration
Portable 3 Phase Portable Reference Standard For Single Phase Meter Calibration
Highly Versatile Portable Reference Standard For All Your Testing Needs
YC98S1 Electrical Tester Calibration Electrical Test Meter Calibration
Product Specification
Supply Ability | 300/Year | Payment Terms | L/C, T/T, D/P |
Model NO. | YC98S1 | Warranty | 1 Year |
Voltage Output | 30V-480V | Current Output | 0.05-10A |
Thermocouple (TC) | No | Resistance-Temperature Detector (RTD) | No |
LCD Display | With LCD Display | Customized | Customized |
Trademark | GENY | Transport Package | Carton |
Specification | 1.5KG | Origin | China |
HS Code | 9030849000 | Port | Guangzhou, China |
Brand Name | GENY | Model Number | YC89S1 |
Certification | ISO, CE | Place of Origin | CHINA |
High Light | Portable Three Phase Standard Meter ,Three Phase Standard Meter Yc98s1 |
Application Conditlons and Requirements | ||||
Environment | Safety | |||
Operation Temperature | Relative Humidity | Altitude | IP Class | Conformity |
-25°C-+45°C | 40%--95% | <2500m | IP30 | CE conform |
Type | YC-98S1 | |||
Test voltage | ||||
Range | 30V-480V | |||
Error | ±0.05% | |||
Harmonic | 2nd-51st | |||
Test current | ||||
Range(direct connection) | 0.05-10A | |||
Range(clamp CT) | 100A | |||
5A,500A,1000A,2000A | ||||
(option) | ||||
Error(direct connection) | ±0.05% | |||
Error(clamp CT) | ±0.2%(5A,100A) | |||
±0.5%(other) | ||||
Harmonic | 2nd-51st | |||
Power measure error | ||||
Active power(direct connection) | ±0.05% | |||
Active power(clamp CT) | ±0.2%(5A,100A) ±0.5%(other) | |||
Reactive power(direct) | ±0.1% | |||
Reactive power(clamp CT) | ±0.2%(5A,100A) | |||
±0.5%(other) | ||||
Energy measure error | ||||
Active energy(direct) | ±0.05% | |||
Active energy(clamp CT) | ±0.2%(5A,100A) | |||
±0.5%(other) | ||||
Reactive energy(direct) | ±0.1% | |||
Reactive energy(clamp CT) | ±0.2%(5A,100A) | |||
±0.5%(other) | ||||
Phase angle | ||||
Range | 0°-360° | |||
Error | ±0.05° | |||
Frequency | ||||
Range | 45Hz-65Hz | |||
Pulse output | ||||
High frequency output(CH) | -- | |||
Low frequency | 3600imp/kWh | |||
Pulse ratioPulse ratio | 1:01 | |||
Output level | 5V | |||
Pulse input | ||||
Input channel | 2 | |||
Input level | 5-10V | |||
Input frequency | Max.100Hz | |||
Display | ||||
Resolution | 7"TFT color | |||
Function | ||||
Vector diagram | √ | |||
Waveform | √ | |||
Energy accumulation | √ | |||
CT ratio test | √ | |||
Local parameter input | √ | |||
Wiring emulation | √ | |||
Self-calibration | √ | |||
Recorder check | √ | |||
Data storage | √ | |||
Data storage qty | 5000 | |||
External extend | √ | |||
Screen printing | √ | |||
Communication port | USB/RS232 | |||
Communication with | √ | |||
Upload data | √ | |||
External mini printer | √ | |||
External keyboard | √ | |||
Other | ||||
Voltage Supply way | External power | |||
test lead power | ||||
Voltage Supply | 55-480V,50/60Hz | |||
Dimensions(WxHxD) | 245x168x67 | |||
Weight(kg) | 1.5kg |
Can test one meter or two meters at the same time.
Automatic test sequence using the scanning head for electronic and electromechanical meters
Can synchronously calculate all data and display on the interface include full wave
Can test active and reactive energy accuracy of full wave meter
Can simultaneously test two channel pulses whose pulse constant
Wiring identification is available when no load.
Electric energy accumulation function can measure the electric energy meter when it has not pulse output.
Dial test function
Display vector diagram
Can identify wrong wiring (48 types connections)
Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation
Harmonic functions
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...