| Payment Terms | L/C,T/T,D/P |
| Supply Ability | 100/Year |
| Delivery Time | 30 days after order confirmed |
| Packaging Details | Plywood case |
| Voltage | 3×230/398V±10% |
| Frequency | 50/60Hz±2Hz |
| Power capacity | > 6kVA |
| Ambient temperature | -10°C -- +40°C |
| Relative humidity | 35% -- 85% |
| Brand Name | GENY |
| Model Number | YC1891D |
| Certification | ISO, CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
YC1893D ThreePhase Energy Meter Testing System Custom OEM and ODM Services
Terminal Connection Meter Tester Yc1891d-6 Meter Test System Accurate Measuremen
0.02% Accuracy Electricity Meter Test Equipment Precise Single Phase
Three Phase Energy Meter Test Equipment Lab Electric Meter Testing Equipment
Product Specification
| Payment Terms | L/C,T/T,D/P | Supply Ability | 100/Year |
| Delivery Time | 30 days after order confirmed | Packaging Details | Plywood case |
| Voltage | 3×230/398V±10% | Frequency | 50/60Hz±2Hz |
| Power capacity | > 6kVA | Ambient temperature | -10°C -- +40°C |
| Relative humidity | 35% -- 85% | Brand Name | GENY |
| Model Number | YC1891D | Certification | ISO, CE |
| Place of Origin | CHINA | ||
| High Light | single phase energy meter tester ,mechanical meter calibration system ,electronic meter test equipment | ||
Suitable for 1P2W (Single-Phase Two-Wire) energy meters
Supports mechanical meters, electromechanical meters, and fully electronic energy meters
Compatible with single-phase meters with I-P links closed (current and voltage circuits linked)
Active power testing
Reactive power testing
Cross-connected reactive power testing
Starting test and creeping (no-load) test
Equipped with current output switch, enabling calibration of 2-element meters
Supports simultaneous testing of meters with identical specifications but different meter constants
Automatic rotor mark positioning for mechanical disc meters, improving test efficiency and repeatability
High-precision error measurement, harmonic testing, demand testing, and influence factor testing
Supports automatic, semi-automatic, and manual test modes
Swing-together scanning heads simplify system control and improve operational stability
Integrated MSVT function for flexible meter testing configurations
Built-in protection against:
Overload
Short-circuited voltage circuits
Open current circuits
Ensures safe and reliable long-term operation
Constructed with high-strength aluminum alloy
Lightweight, corrosion-resistant, and durable
Suitable for laboratory and industrial environments
User-friendly meter testing software based on Windows 2000 / XP / 7 / 8 / 10
Modular software architecture covering all modern energy meter test requirements
Supports:
Accuracy (error) testing
Harmonic analysis
Demand measurement
Influence and environmental testing
| Voltage | |
| Test voltage output (Phase-Neutral) | 24V – 300V |
| Power of the voltage output | 1000VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load regulation from 0-max. load | < 0.01% |
| Distortion factor | < 0.3% for linear resistance load |
| Harmonics | 2nd – 21st free programmable |
| Current | |
| Test current output | 1mA – 120A |
| Power of the current output | 1500VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load regulation from 0-max. load | < 0.01% |
| Distortion factor | < 0.3% for linear resistance load |
| Harmonics | 2nd – 21st free programmable |
| Phase angle | |
| Range | 0 -- 360° |
| Resolution | 0.01° |
| Setting accuracy | 0.1° |
| Frequency | |
| Range | 45Hz – 65Hz |
| Resolution | 0.01Hz |
![]()
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!