| Payment Terms | L/C,T/T,D/P |
| Supply Ability | 100/Year |
| Delivery Time | 4-6weeks |
| Packaging Details | plywood case |
| Reference Standard Meter | SZ03A-K8 (customized) |
| Power Source | YCS-103-250 、YCS-103-600 、YCS-103-1200 、YCS-103-2500 |
| Scanning Head | YCG-S Series |
| Brand Name | GENY |
| Model Number | YC-1891D |
| Certification | ISO, CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Stationary Meter Test System With 0.01 Class Accuracy And Optional Standard
YC-1893R High-grade Three-phase Energy Meter Calibration Device
6/12/24/48 MTUs Electric Meter Test Bench Three Phase Energy Meter Test Bench
Stationary Meter Test System 24 Positions Energy Meter Tester
Product Specification
| Payment Terms | L/C,T/T,D/P | Supply Ability | 100/Year |
| Delivery Time | 4-6weeks | Packaging Details | plywood case |
| Reference Standard Meter | SZ03A-K8 (customized) | Power Source | YCS-103-250 、YCS-103-600 、YCS-103-1200 、YCS-103-2500 |
| Scanning Head | YCG-S Series | Brand Name | GENY |
| Model Number | YC-1891D | Certification | ISO, CE |
| Place of Origin | CHINA | ||
| High Light | 0.05 accuracy poly phase meter tester ,aluminum alloy meter test system ,stationary poly phase test rack | ||
|
Voltage |
||||
|
Test voltage output(Phase-Neutral) |
3x(24V~288V)(or customized) |
|||
|
Power of the voltage output |
Max. to 3x500VA |
|||
|
Resolution |
Better than 0.01% of full scale value of range |
|||
|
Setting accuracy |
Better than 0.05% at the final range value |
|||
|
Stability |
Better than 0.005% /h (integration time 150s) |
|||
|
Load regulation from 0~max. load |
Better than 0.01% |
|||
|
Distortion factor |
Better than 0.3% for linear resistance load |
|||
|
Harmonic |
2nd~21st free programmable |
|||
|
Current |
||||
|
Test current output |
3x(1mA~100A) |
|||
|
Power of the current output |
Max. 3x150VA |
Max. 3x350VA |
Max. 3x750VA |
Max. 3x1500VA |
|
Resolution |
Better than 0.01% of full scale value of range |
|||
|
Setting accuracy |
Better than 0.05% at the final range value |
|||
|
Stability |
Better than 0.005% /h (integration time 150s) |
|||
|
Load regulation from 0~max. load |
Better than 0.01% |
|||
|
Distortion factor |
Better than 0.3% for linear resistance load |
|||
|
Harmonic |
2nd~21st free programmable |
|||
|
Phase angle |
||||
|
Range |
0~360⁰ |
|||
|
Resolution |
0.01⁰ |
|||
|
Setting accuracy |
0.1⁰ |
|||
|
Frequency |
||||
|
Range |
45Hz~65Hz |
|||
|
Resolution |
0.01Hz |
|||
|
Error display |
||||
|
Type of error display |
Red LED |
|||
|
Resolution of error displays |
8 digitals |
|||
|
Other |
||||
|
Voltage supply |
3x220/380V±10%(or customized) 50/60Hz ±2Hz |
|||
|
Ambient temperature |
-10°C~+40°C |
|||
|
Relative humidity |
35%~90% |
|||
1. Installing the ICT in each meter position to test three-phase meters with closed links between the current and voltage measuring circuits(I-P links)
2. The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation.
3. Meters under testing: 3P4W, 3P3W, 1P2W
4. Testing mode: active power, reactive power, cross connected reactive power
5. Simultaneously measure meters with same specifications but different meter constants
6. Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
7. Starting test and creeping test
8. With the protection function of overload, short voltage circuit and open current circuit.
9. The swing together of the scanning heads simplifies the control.
10. Aluminum alloy material, light and strong and corrosion resistant
11. The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,.
1. Forward and reverse active, Forward and reverse reactive error test
2. SW-5D precise time reference source for testing the energy meter daiy time error.
3. Communication test and time calibration with speaker.
4. Check constant (pulse counting,time, demand indication error test)
5. Time switch, demand period and demand indication error test.
6. Register indication and register combination error test.
7. Four quadrant reactive power test
8. Power consumption test(optional).
9. The voltage and current loop of measured meter can be connected together(optional)
10. Tilt impact test(optional)
11. prepayment meter test(optional)
|
Current range |
3×(10mA – 120A) |
|
Accuracy |
0.05 (100mA – 120A) |
|
Ration |
1:1 (primary current = secondary current) |
|
Frequency range |
45Hz – 65Hz |
|
Output burden range |
3×0.6V (max) |
|
Output power |
3×60VA (max) |
|
Communication port |
RS-485 |
|
Power supply |
+/- 12VDC |
|
Power consumption |
20 VA (max) |
|
Operation temperature |
- 10°C … +50°C |
|
Storage temperature |
- 20°C … +60°C |
|
Dimension (H × W × D) |
290mm×275mm×296mm |
|
Wight |
approx.17kg |
![]()
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!