Payment Terms | L/C, T/T, D/P |
Supply Ability | 100/Year |
Model NO. | YC1891D |
After-sales Service | 3 Year |
Warranty | 1 Year |
Application | Electromagnetic Instrument |
Power | Electricity |
Voltage Output | 24V-300V(or Customized) |
Current Output | 1mA-120A/200A |
Thermocouple (TC) | No |
Resistance-Temperature Detector (RTD) | No |
LCD Display | With LCD Display |
Customized | Customized |
Trademark | GENY |
Transport Package | Plywood Case |
Specification | 10.7CBM |
Origin | China |
HS Code | 9030849000 |
Port | Guangzhou, China |
Brand Name | GENY |
Model Number | YC1891D |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Terminal Connection Meter Tester Yc1891d-6 Meter Test System Accurate Measuremen
0.02% Accuracy Electricity Meter Test Equipment Precise Single Phase
Three Phase Energy Meter Test Equipment Lab Electric Meter Testing Equipment
One Phase Energy Meter Testing Equipment Semi Automatic Or Manual Operation
Product Specification
Payment Terms | L/C, T/T, D/P | Supply Ability | 100/Year |
Model NO. | YC1891D | After-sales Service | 3 Year |
Warranty | 1 Year | Application | Electromagnetic Instrument |
Power | Electricity | Voltage Output | 24V-300V(or Customized) |
Current Output | 1mA-120A/200A | Thermocouple (TC) | No |
Resistance-Temperature Detector (RTD) | No | LCD Display | With LCD Display |
Customized | Customized | Trademark | GENY |
Transport Package | Plywood Case | Specification | 10.7CBM |
Origin | China | HS Code | 9030849000 |
Port | Guangzhou, China | Brand Name | GENY |
Model Number | YC1891D | Certification | ISO, CE |
Place of Origin | CHINA | ||
High Light | Industrial Stationary Meter Test Equipment ,Versatile Stationary Meter Test Equipment ,Accurate Stationary Meter Test Equipment |
YC1891D-6 | YC1891D-12 | YC1891D-24 | YC1891D-48 | |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 | |||
Power Source | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 |
Standard Meter | SZ01A-K3 | |||
MSVT | HJ200GL-6 | HJ200GL-12 | HJ200GL-24 | HJ200GL-48 |
QCD | D5 series | |||
Scanning Head | YCG-2 series | |||
Voltage | ||||
Test voltage output | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 1mA – 100A or customized,Max.200A | 1mA – 100A | ||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of the error displays | 8 digits | |||
Voltage Supply | 220V±10% or customized 50/60Hz±2Hz | 3x220/380V±10% or customized 50/60Hz±2Hz | ||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
Meter Test System Overview:
Our advanced meter test system is designed to measure a variety of meters, including mechanical, electronic mechanical, and electronic meters, with options for automatic, semi-automatic, or manual operation. It supports testing of single-phase meters with 1P2W configurations and offers a range of testing modes including active power, reactive power, and cross-connected reactive power.
MSVT capability for testing single-phase meters with I-P links.
Current output switch for optional calibration of 2-element meters.
Simultaneous measurement of meters with identical specifications but varying constants.
Automatic rotor mark positioning for mechanical meters, enhancing efficiency.
Capabilities for starting tests and creeping tests.
Comprehensive protection against overload, short circuits, and open current circuits.
Simplified control with synchronized scanning heads.
Durable aluminum alloy construction for lightweight, strong, and corrosion-resistant design.
User-friendly Windows 2000/XP/7/8/10 compatible software with modules for error testing, harmonic analysis, demand testing, and influence testing.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!