YC-1893GT Rail-Mount Stationary Energy Meter Verification System

  1. MOQ: 1
  2. Price: Negotiate rates
  3. Get Latest Price
Payment Terms T/T, L/C, D/P, T/T
Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks
Packaging Details Plywood cases
Output Voltage Range 3x57.7V / 3x100V / 3x220V / 3x380V
Phase Shift Impact: <0.1%
Output Phase Adjustment Range 0.01°~360°
Load Regulation <±0.3°
Output Frequency Adjustment Range 45Hz to 65Hz
Brand Name GENY
Model Number YC-1891GT
Certification ISO, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/P, T/T Supply Ability 5 sets / 1 months
Delivery Time 6~8weeks Packaging Details Plywood cases
Output Voltage Range 3x57.7V / 3x100V / 3x220V / 3x380V Phase Shift Impact: <0.1%
Output Phase Adjustment Range 0.01°~360° Load Regulation <±0.3°
Output Frequency Adjustment Range 45Hz to 65Hz Brand Name GENY
Model Number YC-1891GT Certification ISO, CE
Place of Origin China
High Light Stationary Energy Meter Verification System

YC-1893GT Rail-Mount Stationary Energy Meter Verification System

Device Features

  • Flexible System Characteristics
  • RJ-45 / RS-485 / CAN Interface
  • Carrier / Remote Signal / State Grid Bluetooth Communication Interface
  • Microcomputer Automatic Calibration Operation and Keyboard Manual Calibration Operation
  • Flexible Calibration Plan Settings
  • Various Report Formats that Can Be Modified According to User Requirements
  • Communication Protocol for Smart Metering
  • Barcode Input and Networking Functions
  • Supports 645, 698 Communication Protocols

 

Technical Specifications

Device Accuracy Level: 0.05 Level / 0.1 Level

Output Voltage

  • Range: 3x57.7V / 3x100V / 3x220V / 3x380V
  • Adjustment Range: 0~120% Un
  • Adjustment Precision: Minimum 1mV
  • Waveform Distortion: ≤0.3%
  • Phase Shift Impact: <0.1%
  • Load Regulation: ≤±0.3% of Full Scale Value (Pure Resistive, Inductive, Capacitive)
  • Monitoring Accuracy: Multi-functional Standard Meter Monitoring

Output Current

  • Range: 3x0.02A~100A Automatic Range Selection (Power Source Part, Default Imax=50A)
  • 3x0.2A~500A (Through 1:10 ICT Transformation Output. ICT Accuracy Level: 0.01.)
  • CT Transformation Output, Starting Current: 200mA (Minimum), Starting Current Accuracy ≤3%
  • Simulated Rogowski Coil Output Voltage: 0.16mV-400mV (Corresponding to Rail Meter 0.2A~500A Input)
  • Adjustment Range: 0~120% In
  • Adjustment Precision: Minimum 0.1mA (Power Source Part)
  • Waveform Distortion: ≤0.3%
  • Phase Shift Impact: <0.1%
  • Load Regulation: ≤±0.3% of Full Scale Value (Pure Resistive, Inductive, Capacitive)
  • Monitoring Accuracy: Multi-functional Standard Meter Monitoring

Output Phase

  • Adjustment Range: 0.01°~360°
  • Adjustment Precision: Minimum 0.01°
  • Load Regulation: <±0.3°
  • Monitoring Accuracy: Multi-functional Standard Meter Monitoring

Output Frequency

  • Adjustment Range: 45.000Hz~65.000Hz
  • Adjustment Precision: Minimum 0.001Hz
  • Load Regulation: <±0.1%
  • Monitoring Accuracy: Multi-functional Standard Meter Monitoring

Output Power Symmetry

  • When the device indicates (or defaults to) symmetry, the actual output symmetry should not exceed the specifications in Table 3-3.

Output Power Stability

  • After the device reaches a thermally stable state, within the specified output load range, the output power stability Py should not exceed the specifications in Table 3-4.

                                                              (Table 3-3)

Device Accuracy Level Voltage Symmetry (%) Current Symmetry (%) Phase Symmetry (°)
0.05 Level ±0.5 ±1.0 2
0.1 Level ±0.5 ±1.0 2

 

                          (Table 3-4)

Device Accuracy Level 0.05 Level 0.1 Level
γР at 1.0 0.02 0.05
γР at 0.5L 0.05 0.1

 

Timing Signal

  • Modular Timing Frequency Meter, Output Timing Frequency 625kHz
  • Internal Crystal Oscillator Frequency Accuracy ≤0.4x10^-6, Annual Stability ≤0.1x10^-6
  • (The above are default configurations, for other performance parameters and functions, please contact our company for customization)

 

 

 

 

Certification

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement