China 3-48 Position Meter Testing Equipment With Precise Four Quadrant Reactive Power
China 3-48 Position Meter Testing Equipment With Precise Four Quadrant Reactive Power

  1. China 3-48 Position Meter Testing Equipment With Precise Four Quadrant Reactive Power

3-48 Position Meter Testing Equipment With Precise Four Quadrant Reactive Power

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms L/C,T/T,D/P
Supply Ability 100/Year
Model NO. YC1893D
Number of meter positions equipped ICT 3-48
Accuracy 0.05
Reference Standard Meter SZ03A-K8 (customized)
Test voltage output(Phase-Neutral) 3x(24V~288V)(or customized)
Brand Name GENY
Model Number YC-1893D
Certification ISO, CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T,D/P Supply Ability 100/Year
Model NO. YC1893D Number of meter positions equipped ICT 3-48
Accuracy 0.05 Reference Standard Meter SZ03A-K8 (customized)
Test voltage output(Phase-Neutral) 3x(24V~288V)(or customized) Brand Name GENY
Model Number YC-1893D Certification ISO, CE
Place of Origin CHINA
High Light 48 Position Meter Testing EquipmentReactive Power Meter Testing Equipment3 Position Meter Testing Equipment

3-48 Position Meter Testing Equipment with Precise Four Quadrant Reactive Power Test


Standard Function


1. The installation of ICT in each meter position is required to test three-phase meters with closed links between the current and voltage measuring circuits (I-P links).
2. The meter test system is capable of measuring mechanical and electronic meters, as well as electronic meters, through automatic, semi-automatic or manual operation.
3.Meters under testing: The following configurations are available: 3P4W, 3P3W and 1P2W.
4.The testing mode encompasses the following: active power, reactive power and cross-connected reactive power.
5.Please note that the meters should be measured simultaneously. These meters should have the same specifications but different meter constants.
6. The automatic positioning rotor mark of the disc of the mechanical meter is more efficient.
7. Initiating the test and the creep test.
8. The product incorporates a range of safety features, including overload, short-voltage and open-current circuit protection.
9. The synchronised movement of the scanning heads streamlines the control process.
10. The aluminium alloy is a lightweight yet durable and corrosion-resistant material.
11. The testing software, compatible with Windows 2000, XP, 7, 8 and 10, includes a range of functional modules for various modern energy meters. These modules facilitate testing for real-time error, harmonic, demand and influence, among others.


Product Parameters



Technical spec.


Number of meter positions equipped ICT

3-48

Accuracy class of ICT

0.02

Accuracy

0.05

Power Source

YCS-103-250

YCS-103-600

YCS-103-1200

YCS-103-2500

Reference Standard Meter

SZ03A-K8 (customized)

Scanning Head

YCG-S Series

Voltage Source


Test voltage output(Phase-Neutral)

3x(24V~288V)(or customized)

Power of the voltage output

Max. to 3x500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Current Source


Test current output

3x(1mA~100A)

Power of the current output

Max. 3x150VA

Max. 3x350VA

Max. 3x750VA

Max. 3x1500VA

Resolution

Better than 0.01% of full scale value of range

Setting accuracy

Better than 0.05% at the final range value

Stability

Better than 0.005% /h (integration time 150s)

Load regulation from 0~max. load

Better than 0.01%

Distortion factor

Better than 0.3% for linear resistance load

Harmonic

2nd~21st  free programmable

Phase angle


Range

0~360⁰

Resolution

0.01⁰

Setting accuracy

0.1⁰

Frequency


Range

45Hz~65Hz

Resolution

0.01Hz

Error display


Type of error display

Red LED

Resolution of error displays

8 digitals

Other


Voltage supply

3x220/380V±10%(or customized)

50/60Hz ±2Hz

Ambient temperature

-10°C~+40°C

Relative humidity

35%~85%



For more information, please visit my official website:http://www.genymetertestequipment.com/


Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement