Payment Terms | L/C,T/T,D/P |
Model NO. | YC98S1 |
Voltage Output | 30V-480V |
Current Output | 0.05-10A |
LCD Display | With LCD Display |
Brand Name | GENY |
Model Number | YC89S1 |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High Precision Portable Reference Standard For Single Phase Meter Calibration
Portable 3 Phase Portable Reference Standard For Single Phase Meter Calibration
Highly Versatile Portable Reference Standard For All Your Testing Needs
YC98S1 Electrical Tester Calibration Electrical Test Meter Calibration
Product Specification
Payment Terms | L/C,T/T,D/P | Model NO. | YC98S1 |
Voltage Output | 30V-480V | Current Output | 0.05-10A |
LCD Display | With LCD Display | Brand Name | GENY |
Model Number | YC89S1 | Certification | ISO, CE |
Place of Origin | CHINA |
Test Voltage (Full Wave & Fundamental Wave) | |||
Range | 0~500V | ||
Error | ±0.05% (0.1%) | ||
Harmonic | 2nd ~ 51st | ||
Test Current (Full Wave & Fundamental Wave) | |||
Range (direct connection) | 0.025A ~ 12A (Ie=5A) | ||
Range (100AClamp CT) | 0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie) (Optional: Ie=5A, 500A, 1000A) | ||
Error (direct connection) | ±0.05% (0.1%) | ||
Error (100AClamp CT) | ±0.2%(5A,100A) ±0.5% (other) | ||
Harmonic | 2nd ~ 51st | ||
Starting current | 0.05%Ie | ||
Power Measure Error (Full Wave & Fundamental Wave) | |||
Active Power (Direct connection) | ±0.05% | ||
Active Power (100A ClampCT) | ±0.2%(5A,100A) ±0.5% (other) | ||
Reactive Power (Direct connection) | ±0.1% | ||
Reactive Power (100A ClampCT) | ±0.5%(5A,100A) ±1.0% (other) | ||
Energy Measure Error (Full Wave & Fundamental Wave) | |||
Active Energy (Direct connection) | ±0.05% (±0.1%) | ||
Active Energy (100A ClampCT) | ±0.2%(5A,100A) ±0.5% (other) | ||
Reactive Energy (Direct connection) | ±0.1% | ||
Reactive Energy (100A ClampCT) | ±0.5%(5A,100A) ±1.0% (other) | ||
Error (Harmonic Wave) | |||
Direct Connection | kWh,U, I, P, Q, S | ±0.2%H (H=1+0.01k, k=2~51) | |
Clamp CT 5A/100A | kWh,U, I, P, Q, S | ±0.5%H (H=1+0.01k, k=2~51) | |
Cycle Output Current for 5A CCT’s Self Calibration | 0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A | ||
Error of 5ACCT’s Self Calibration (linear and phase error) | ±0.1% | ||
Clamp CT 500A/1000A | kWh,U, I, P, Q, S | ±1.0%H (H=1+0.01k, k=2~51) | |
Error - Others | |||
Ratio Measurement | ±0.5% | ||
Voltage Influence | <±0.01% | ||
Frequency Influence | <±0.01% | ||
Temperature Influence | <±0.01%/℃ | ||
24h Accuracy Influence | <±0.01% | ||
Harmonic Influence | <±0.01% | ||
Phase angle | |||
Range | -180°~ 180° | ||
Error | <±0.1° | ||
Frequency | |||
Range | 45 ~ 65Hz | ||
Error | ±0.01Hz | ||
Pulse output | |||
Inner High frequency (CH) | Direct connection | 1.8x109 P/kWh | |
Clamp CT | 1.8x109 *(5/Ie)P/kWh | ||
Low frequency output | Direct connection | 3600P, 36000P, 360000P/kWh(kvarh, kVAh) | |
Clamp CT | 3600P, 36000P, 360000P *(5/Ie)P/kWh(kvarh, kVAh) | ||
Pulse ratio | 1:1 | ||
Output level | +5V (can be adjusted according to request) | ||
Pulse input | |||
Input Channel | 2 | ||
Input level | 5 ~ 10V | ||
Max Pulse Input frequency | Max. 10kHz | ||
Display | |||
Resolution | 7’’TFT Touch Screen | ||
System | Windows CE | ||
Other | |||
Voltage supply mode | External power, Tested circuit, Battery | ||
Working power supply | AC 55~600V | ||
Voltage Withstand | 4.0kV (voltage ¤t terminals, power supply & low voltage terminals) | ||
EFT(Electrical Fast Transient) | 2.0kV | ||
IP Level | IP51 | ||
Surge | 2.0kV (common mode), 2.0kV (different mode) | ||
Power on Stability Time | < 3mins | ||
Chargeable battery | 11.1V 3000mAh | ||
Power Consumption | <9W | ||
Operation Temperature | Temperature -20℃ ~ +55℃, humidity 40% ~ 95% | ||
Storage Temperature | Temperature -40℃ ~ +80℃, humidity 40% ~ 95% | ||
Dimension (mm) (W×H×D) | Main | 245×150×50 | |
Carry case | 425×336×196 | ||
Weight (kg) | Main | 2 | |
Whole set | 10 |
1.Multi-Meter Testing:
Tests one or two meters simultaneously, with error display precise to five digits and three decimal places.
2.Automated/Manual Testing:
Automated test sequence for electronic and electromechanical meters.
Manual control via start/stop button or firmware.
3.Data Calculation and Display:
Displays full wave, fundamental wave, harmonic wave data, and U, I, P, Q, VA, phase angle.
Shows positive/negative sequence, zero sequence, and harmonic content.
4.Energy Accuracy Testing:
Tests active/reactive energy for full wave, fundamental wave, and harmonic wave meters.
Tests apparent energy accuracy.
5.Dual-Channel Pulse Testing:
Simultaneous testing of two channels with different pulse constants and modes.
6.Wiring Identification and Energy Accumulation:
Identifies wiring without load.
Measures energy meters without pulse output.
7.Dial Test Function:
Time method or energy method available.
8.Waveform and Vector Display:
Displays vector diagrams and three-phase voltage/current waveforms.
9.Wrong Wiring Identification:
Detects 48 types of three-phase and 96 types of four-wire connections.
Identifies CT secondary crossing wiring.
10.Wiring Simulation and Training:
Simulates wiring scenarios for training and parameter revision without voltage/current signals.
1.Harmonic Analysis:
Calculates harmonic compound of U, I, P, Q, VA and their percentages.
Analyzes up to 51st harmonic (+PH/-PH) and their impact on meter metrology.
2.Full Wave Reactive Power:
Algebraic sum of fundamental and harmonic waves.
Avoids errors from 90-degree phase shift method by selecting harmonic wave numbers based on meter bandwidth.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!