China YC-98S1 Portable Three Phase Standard Meter
China YC-98S1 Portable Three Phase Standard Meter

  1. China YC-98S1 Portable Three Phase Standard Meter

YC-98S1 Portable Three Phase Standard Meter

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms L/C,T/T,D/P
Model NO. YC98S1
Voltage Output 30V-480V
Current Output 0.05-10A
LCD Display With LCD Display
Brand Name GENY
Model Number YC89S1
Certification ISO, CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T,D/P Model NO. YC98S1
Voltage Output 30V-480V Current Output 0.05-10A
LCD Display With LCD Display Brand Name GENY
Model Number YC89S1 Certification ISO, CE
Place of Origin CHINA

 YC-98S1 Portable Three Phase Standard Meter



The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323 (IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure AC parameter of three phase power grid.

This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001), GB/T4793.2-2008 (IEC61010-1:2001)


Product Parameters



Test Voltage    (Full Wave & Fundamental Wave)



Range

0~500V



Error

±0.05% (0.1%)



Harmonic

2nd ~ 51st



Test Current    (Full Wave & Fundamental Wave)



Range  (direct connection)

0.025A ~ 12A    (Ie=5A)



Range   (100AClamp CT)

0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie)

(Optional: Ie=5A, 500A, 1000A)



Error  (direct connection)

±0.05% (0.1%)



Error   (100AClamp CT)

±0.2%(5A,100A)    ±0.5% (other)



Harmonic

2nd ~ 51st



Starting  current

0.05%Ie



Power Measure Error    (Full Wave & Fundamental Wave)



Active  Power (Direct  connection)

±0.05%



Active  Power (100A ClampCT)

±0.2%(5A,100A) ±0.5% (other)



Reactive  Power (Direct  connection)

±0.1%



Reactive Power (100A ClampCT)

±0.5%(5A,100A)    ±1.0% (other)



Energy Measure Error    (Full Wave & Fundamental Wave)

Active  Energy (Direct  connection)

±0.05% (±0.1%)

Active  Energy (100A ClampCT)

±0.2%(5A,100A)    ±0.5% (other)

Reactive  Energy (Direct  connection)

±0.1%

Reactive  Energy (100A ClampCT)

±0.5%(5A,100A) ±1.0% (other)

Error (Harmonic Wave)

Direct Connection

kWh,U, I, P, Q, S

±0.2%H (H=1+0.01k, k=2~51)

Clamp CT 5A/100A

kWh,U, I, P, Q, S

±0.5%H (H=1+0.01k, k=2~51)

Cycle Output Current for 5A CCT’s  Self Calibration

0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

Error of 5ACCT’s Self Calibration

(linear and phase error)

±0.1%

Clamp CT 500A/1000A

kWh,U, I, P, Q, S

±1.0%H (H=1+0.01k, k=2~51)

Error - Others

Ratio  Measurement

±0.5%

Voltage  Influence

<±0.01%

Frequency  Influence

<±0.01%

Temperature  Influence

<±0.01%/℃

24h  Accuracy  Influence

<±0.01%

Harmonic  Influence

<±0.01%

Phase angle

Range

-180°~ 180°

Error

<±0.1°

Frequency

Range

45 ~ 65Hz

Error

±0.01Hz

Pulse output

Inner High frequency (CH)

Direct connection

1.8x109 P/kWh

Clamp CT

1.8x109 *(5/Ie)P/kWh

Low  frequency output

Direct connection

3600P, 36000P,

360000P/kWh(kvarh, kVAh)

Clamp CT

3600P, 36000P, 360000P

*(5/Ie)P/kWh(kvarh, kVAh)

Pulse  ratio

1:1

Output  level

+5V (can be adjusted according to request)

Pulse input

Input  Channel

2

Input  level

5 ~ 10V

Max  Pulse  Input  frequency

Max. 10kHz

Display

Resolution

7’’TFT Touch Screen

System

Windows CE

Other

Voltage  supply  mode

External power, Tested circuit, Battery

Working power  supply

AC 55~600V

Voltage  Withstand

4.0kV (voltage ¤t terminals, power supply & low voltage terminals)

EFT(Electrical  Fast  Transient)

2.0kV

IP  Level

IP51

Surge

2.0kV (common mode), 2.0kV (different mode)

Power  on  Stability  Time

< 3mins

Chargeable battery

11.1V 3000mAh

Power  Consumption

<9W

Operation  Temperature

Temperature -20℃ ~ +55℃, humidity 40% ~ 95%

Storage  Temperature

Temperature -40℃ ~ +80℃, humidity 40% ~ 95%

Dimension (mm) (W×H×D)

Main

245×150×50

Carry case

425×336×196

Weight  (kg)

Main

2

Whole set

10



Test Functions


1.Multi-Meter Testing:

Tests one or two meters simultaneously, with error display precise to five digits and three decimal places.

2.Automated/Manual Testing:

Automated test sequence for electronic and electromechanical meters.

Manual control via start/stop button or firmware.

3.Data Calculation and Display:

Displays full wave, fundamental wave, harmonic wave data, and U, I, P, Q, VA, phase angle.

Shows positive/negative sequence, zero sequence, and harmonic content.

4.Energy Accuracy Testing:

Tests active/reactive energy for full wave, fundamental wave, and harmonic wave meters.

Tests apparent energy accuracy.

5.Dual-Channel Pulse Testing:

Simultaneous testing of two channels with different pulse constants and modes.

6.Wiring Identification and Energy Accumulation:

Identifies wiring without load.

Measures energy meters without pulse output.

7.Dial Test Function:

Time method or energy method available.

8.Waveform and Vector Display:

Displays vector diagrams and three-phase voltage/current waveforms.

9.Wrong Wiring Identification:

Detects 48 types of three-phase and 96 types of four-wire connections.

Identifies CT secondary crossing wiring.

10.Wiring Simulation and Training:

Simulates wiring scenarios for training and parameter revision without voltage/current signals.


Harmonic Functions


1.Harmonic Analysis:

Calculates harmonic compound of U, I, P, Q, VA and their percentages.

Analyzes up to 51st harmonic (+PH/-PH) and their impact on meter metrology.

2.Full Wave Reactive Power:

Algebraic sum of fundamental and harmonic waves.

Avoids errors from 90-degree phase shift method by selecting harmonic wave numbers based on meter bandwidth.



Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement