Payment Terms | L/C, T/T |
Supply Ability | 750 units/week |
Delivery Time | 10 days |
Packaging Details | main unit 78*49*32CM trolley 70*55*23.5CM |
Screen size | 5.7 inch color screen |
Oxygen concentration | 21%~100%, (increment by 1%) |
Target tidal volume | 20~2500mL |
Backup BPM | 1~60BPM |
Flow of HFNC mode | 10~70L/min |
Max flow | 300L/min |
Max leak compensation | 120L/min |
IPAP | 4~40cm H2O |
EPAP | 4~25cm H2O |
CPAP | 4~20cm H2O |
Brand Name | Micomme |
Model Number | ST-30K |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
High Performance 10~70L/min Non Invasive Ventilator Machine
ST-30K 300L/Min Non Invasive Ventilator Machine In ICU
Perfect combination of NIV and HFNC ventilation solution with ST-30K
Micomme Hospital Non Invasive Ventilator ST-30H With 5.7 Inch Color Screen
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 750 units/week |
Delivery Time | 10 days | Packaging Details | main unit 78*49*32CM trolley 70*55*23.5CM |
Screen size | 5.7 inch color screen | Oxygen concentration | 21%~100%, (increment by 1%) |
Target tidal volume | 20~2500mL | Backup BPM | 1~60BPM |
Flow of HFNC mode | 10~70L/min | Max flow | 300L/min |
Max leak compensation | 120L/min | IPAP | 4~40cm H2O |
EPAP | 4~25cm H2O | CPAP | 4~20cm H2O |
Brand Name | Micomme | Model Number | ST-30K |
Certification | CE | Place of Origin | China |
MICOMME HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with PERFECT COMBINATION of NIV and HFNC
Description
Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient's upper airway using a mask or similar device.
Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.
Application
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
The patients with known or suspected COVID-19 with respiratory failure should be intubated and ventilated early in the disease course without the option for less invasive treatments, including non-invasive ventilation (NIV).
Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.
Increased quality of life: NIV increases the quality of life for patients.
Advantage
Maximum inspiratory pressure: 40cm H2O
HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.
6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
5.7-inch LCD color screen, flow rate and pressure double waveform, setting, alarm, treatment information displayed on the screen, combined with a knob. A single page can complete all settings.
Parameters setting and real-time treatment data display on the same screen, convenient to adjust the parameters according to patients’ conditions.
Specifications
|
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2013
Total Annual:
45000000-90000000
Employee Number:
300~500
Ecer Certification:
Active Member
Micomme Medical Technology Development Co., Ltd has been established in Changsha and officially entered into non- invasive ventilator field in 2013. Micomme Medical focused on innovation for respiratory therapy and chronic respiratory disease service, we strive to become the top non-i... Micomme Medical Technology Development Co., Ltd has been established in Changsha and officially entered into non- invasive ventilator field in 2013. Micomme Medical focused on innovation for respiratory therapy and chronic respiratory disease service, we strive to become the top non-i...
Get in touch with us
Leave a Message, we will call you back quickly!