Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"BVR Cable 450\/750V PVC Insulated Flame Retardant House Wire for Building Wiring","imgUrl":"https:\/\/img.chinax.com\/nimg\/fa\/e1\/5350e1d78a750f055f9e617e3348-200x200-1\/bvr_cable_450_2f750v_pvc_insulated_flame_retardant_house_wire_for_building_wiring.jpg","attrs":{"Brand Name":"Minfeng","Model Number":"BVR cable","Certification":"ISO,CE,IEC,TUV,KEMA","Place of Origin":"Hebei, China"}}
{"title":"450\/750V Electrical Cable Wire For House Wiring PVC Insulation Copper Conductor","imgUrl":"https:\/\/img.chinax.com\/nimg\/03\/ba\/1292066f7385c2a9793dc9d54a8d-200x200-1\/450_2f750v_electrical_cable_wire_for_house_wiring_pvc_insulation_copper_conductor.jpg","attrs":{"Brand Name":"Minfeng","Model Number":"BVR cable","Certification":"ISO,CE,IEC,TUV,KEMA","Place of Origin":"Hebei, China"}}
{"title":"2.5mm 1.5mm2 Electric Wire Cable Copper Core PVC Insulated For Building Wiring","imgUrl":"https:\/\/img.chinax.com\/nimg\/12\/27\/8ac834d87f62904f29fd15548743-200x200-1\/2_5mm_1_5mm2_electric_wire_cable_copper_core_pvc_insulated_for_building_wiring.jpg","attrs":{"Brand Name":"Minfeng","Model Number":"BV cable","Certification":"ISO,CE,IEC,TUV,KEMA","Place of Origin":"Hebei, China"}}
{"title":"0.6\/1kV GSW Braided Armoured HEPR Insulation Low Voltage Power Cable with","imgUrl":"https:\/\/img.chinax.com\/nimg\/3c\/1c\/8b008cf337dfcb34065aa2f75667-200x200-1\/0_6_2f1kv_gsw_braided_armoured_hepr_insulation_low_voltage_power_cable_with_flexible_bare_copper_class_5_conductor.jpg","attrs":{"Packing Length":"500 meters per drum","Standard Compliance":"HD 308 S2 CEI UNEL 00722-000725 EN 50334","Cable Mark":"Ink Printing or Embossing","Payment Terms":"L\/C,T\/T"}}
FEATURES / BENEFITS * Ultra Low AttenuationThe reduced attenuation of coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies.
* Complete ShieldingThe solid outer conductor of coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
* Low VSWRSpecial low VSWR versions of coaxial cables contribute to low system noise.
* Outstanding Intermodulation Performance coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the factory. * High Power RatingDue to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, cable provides safe long term operating life at high transmit power levels. * Wide Range of ApplicationTypical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects
STRUCTURE Size 1/2 Inner Conductor Diameter mm (in) 4.8 (0.189) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 11.3 (0.445) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 13.8 (0.543) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 15.8 (0.622) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1 Maximum Frequency GHz 8.8 Velocity % 87 Capacitance pF/m (pF/ft) 76 (23.2) Inductance uH/m (uH/ft) 0.19 (0.058) Peak Power Rating kW 38 RF Peak Voltage Volts 1950 Jacket Spark Volt RMS 8000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.62 (0.5) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 3.55 (1.08) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.18 (0.125) Minimum Bending Radius, Single Bend mm (in) 70 (2.756) Minimum Bending Radius, Repeated Bends mm (in) 125 (4.921) Bending Moment Nm (lb-ft) 6.5 (4.79) Tensile Strength N (lb) 1050 (236) Recommended / Maximum Clamp Spacing m (ft) 0.6 / 1 (2 / 3.25)
STRUCTURE Size 1/4 Inner Conductor Diameter mm (in) 2.4 (0.094) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 6 (0.236) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 7.5 (0.295) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 10 (0.394) Jacket Material Black Polyethylene
TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1.5 Maximum Frequency GHz 15.8 Velocity % 83 Capacitance pF/m (pF/ft) 80 (24) Inductance uH/m (uH/ft) 0.205 (0.063) Peak Power Rating kW 10.9 RF Peak Voltage Volts 1050 Jacket Spark Volt RMS 5000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 6.1 (1.86) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 4.4 (1.34) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.095 (0.064) Minimum Bending Radius, Single Bend mm (in) 40 (1.575) Minimum Bending Radius, Repeated Bends mm (in) 85 (3.346) Bending Moment Nm (lb-ft) 1.9 (1.4) Tensile Strength N (lb) 890 (200) Recommended / Maximum Clamp Spacing m (ft) 0.5 / 1 (1.75 / 3.25)
STRUCTURE Size 3/8 Inner Conductor Diameter mm (in) 3.1 (0.122) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 7.2 (0.283) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 9.5 (0.374) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 11.2 (0.441) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1.5 Maximum Frequency GHz 13.5 Velocity % 88 Capacitance pF/m (pF/ft) 76 (23.2) Inductance uH/m (uH/ft) 0.19 (0.058) Peak Power Rating kW 15.4 RF Peak Voltage Volts 1240 Jacket Spark Volt RMS 5000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 3.8 (1.16) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 2.9 (0.88) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.13 (0.087) Minimum Bending Radius, Single Bend mm (in) 50 (2) Minimum Bending Radius, Repeated Bends mm (in) 95 (4) Bending Moment Nm (lb-ft) 1.9 (1.4) Tensile Strength N (lb) 530 (119) Recommended / Maximum Clamp Spacing m (ft) 0.5 / 1 (1.75 / 3.25)
STRUCTURE Size 7/8 Inner Conductor Diameter mm (in) 9.1 (0.358) Inner Conductor Material Copper Tube Dielectric Diameter mm (in) 21.5 (0.846) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 25.2 (0.992) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 27.8 (1.094) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1 Maximum Frequency GHz 5 Velocity % 88 Capacitance pF/m (pF/ft) 74 (22.5) Inductance uH/m (uH/ft) 0.185 (0.056) Peak Power Rating kW 85 RF Peak Voltage Volts 2920 Jacket Spark Volt RMS 8000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 2.04 (0.62) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.55 (0.472) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.39 (0.262) Minimum Bending Radius, Single Bend mm (in) 120 (5) Minimum Bending Radius, Repeated Bends mm (in) 250 (10) Bending Moment Nm (lb-ft) 13 (10) Tensile Strength N (lb) 1440 (324) Recommended / Maximum Clamp Spacing m (ft) 0.8 / 1 (2.75 / 3.25)
Structure Cable Type Foam-Dielectric, Corrugated Size 1-1/4 Jacket Option Black Inner Conductor Diameter mm (in) 13.1 (0.52) Inner Conductor Material Copper Tube Dielectric Diameter mm (in) 32.7 (1.29) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 35.9 (1.41) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 39 (1.54) Jacket Material Polyethylene, PE, Metalhydroxite Filling Testing and Environmental Fire Performance Flame Retardant, LS0H Installation Temperature °C(°F) -15 to 60 (5 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
Electrical Specifications Impedance Ω 50 +/- 1 Maximum Frequency GHz 3.7 Velocity % 89 Capacitance pF/m (pF/ft) 75 (22.9) Inductance uH/m (uH/ft) 0.188 (0.057) Peak Power Rating kW 176 RF Peak Voltage Volts 4200 Jacket Spark Volt RMS 10000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.83 (0.25) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.73 (0.22) Return Loss (VSWR) Performance Standard (for 40-2700, 3300-3700 MHz) or Premium Min. Return Loss (Max. VSWR) dB (VSWR) Standard 20 (1.222), Premium 24 (1.135)/ 23 (1.152) Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Temperature & Power Standard Mechanical Specifications Cable Weight, Nominal kg/m (lb/ft) 0.97 (0.65) Minimum Bending Radius, Single Bend mm (in) 200 (8) Minimum Bending Radius, Repeated Bends mm (in) 380 (15) Bending Moment Nm (lb-ft) 43 (32) Tensile Strength N (lb) 2490 (560) Recommended / Maximum Clamp Spacing m (ft) 1 / 1.2 (3.25 / 4)
Structure Cable Type Foam-Dielectric, Corrugated Size 1-5/8 Jacket Option Black Inner Conductor Diameter mm (in) 17.6 (0.69) Inner Conductor Material Corrugated Copper Tube Dielectric Diameter mm (in) 42.4 (1.67) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 46.4 (1.83) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 50.2 (1.98) Jacket Material Polyethylene, PE, Metalhydroxite Filling Testing and Environmental Fire Performance Flame Retardant, LS0H Installation Temperature °C(°F) -15 to 60 (5 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
Electrical Specifications Impedance Ω 50 +/- 1 Maximum Frequency GHz 2.75 Velocity % 90 Capacitance pF/m (pF/ft) 74 (22.5) Inductance uH/m (uH/ft) 0.185 (0.056) Peak Power Rating kW 310 RF Peak Voltage Volts 5600 Jacket Spark Volt RMS 10000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.3 (0.4) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.47 (0.14) Return Loss (VSWR) Performance Stamdard (for 40-2700 MHz) or Premium Min. Return Loss (Max. VSWR) dB (VSWR) Standard 20 (1.222), Premium 24 (1.135)/ 23 (1.152) Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Temperature & Power Standard Mechanical Specifications Cable Weight, Nominal kg/m (lb/ft) 1.25 (0.84) Minimum Bending Radius, Single Bend mm (in) 200 (8) Minimum Bending Radius, Repeated Bends mm (in) 500 (20) Bending Moment Nm (lb-ft) 42 (31) Tensile Strength N (lb) 2500 (562) Recommended / Maximum Clamp Spacing m (ft) 1.2 / 1.5 (4 / 5)