{"title":"YJV 0.6\/1KV 3*25+2*16 Low Voltage Cable XLPE Insulated PVC Sheath Power Cable","imgUrl":"https:\/\/img.chinax.com\/nimg\/fd\/d3\/77a378528b15a72b518447fc262d-200x200-1\/yjv_0_6_2f1kv_3_2a25_2b2_2a16_low_voltage_cable_xlpe_insulated_pvc_sheath_power_cable.jpg","attrs":{"Supply Ability":"100KM\/Week","Delivery Time":"10 Days","Model No":"Low Voltage Power Cable","Model Number":"Low Voltage Power Cable"}}
{"title":"3 Core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable","imgUrl":"https:\/\/img.chinax.com\/nimg\/21\/76\/6b4cc2c6d4f337ccc5bddcdd5c04-200x200-1\/3_core_copper_conductor_medium_voltage_armoured_xlpe_insulated_power_cable.jpg","attrs":{"Core Type":"Single core or multi-core","Supply Ability":"100KM\/Week","Conductor Material":"Copper or Aluminum","Temperature Range":"<=90\u2103"}}
{"title":"Low Voltage CXV CU XLPE PVC Electrical Armoured Cable 4x16mm2 4x50mm2 4x70mm2","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/08\/b2c9e90fa531dae6e88d09805fb6-200x200-1\/low_voltage_cxv_cu_xlpe_pvc_electrical_armoured_cable_4x16mm2_4x50mm2_4x70mm2_4x95mm2_4x120mm2_4x150mm2_power_cable.jpg","attrs":{"Supply Ability":"100KM\/Week","Core":"1, 2, 3, 4, 5, 3+1, 4+1, 3+2","Outer Sheath Color":"Black or as per required","Certification":"ISO,CE,IEC,TUV,KEMA"}}
{"title":"YJV Cable Medium Voltage XLPE Insulated Power Cable 15kV Rated Voltage 3 Core","imgUrl":"https:\/\/img.chinax.com\/nimg\/2d\/2c\/edefb403f8b53374f14dc0abaecf-200x200-1\/yjv_cable_medium_voltage_xlpe_insulated_power_cable_15kv_rated_voltage_3_core_steel_armored_cable.jpg","attrs":{"Model Number":"xlpe power cable","Type":"YJV YJV22 YJV32","Minimum Order Quantity":"100","Cores No":"1-5"}}
The main function of XLPE Insulated Power Cable is to transport electricity, which is suitable for use in power distribution networks or fixed installations for industrial equipments operating at rated voltage up to and including 0.6/1, 1.8/3, 3.6/6, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 26/35kV with alternating current(AC) 50Hz.This product is usually used under a normal used condition, which does not apply to some special conditions, such as overhead, underwater, ship, submarine, nuclear power station, etc. XLPE insulated flame-retardant power cable, with good performance on preventing fire burning on the circuit, can avoid fire accidents and losses. It is suitable for used in the places where the cable needed to be fixed and installed at high density level, like subway, tunnels and high-rise buildings etc. XLPE polyethylene insulated low-smoke zero-halogen flame-retardant power cables, a kind of environmental product, has good performance on flame-retardant, corrosion resistance and low-smoke, which is suitable to be laid and fixed in crowded places, such as subway, shopping mall or school etc.
2. Technique Features & Standard.
XLPE polyethylene insulated power cables, this product is manufactured by parasitical cross-linking procedure, the straight-chain polyethylene will be changed as network structure by use this method, which transformed thermoplastic material into thermosetting material. The working temperature is up to 90ºC, which can raise the cable current capacity highly. XLPE polyethylene insulated power cables, the product has good performance on electrical characteristic, heat resistance, chemical resistance, environmental stress cracking resistance and aging resistance, all which make the cable has a long useful life.
GB/12706-2008, IEC60502-1,IEC 60228,IEC60332 BS 5467,IS 1554 , IS 7098 ect. we can also design and produce for special application requirement.
3. Operating Characteristics.
3.1 U0/U(Um) Rated Voltage of Cable
,0.6/1(1.2) No. of cores : 1 , 2 , 3, 4 , 5, 3+1 , 4+1 ,3+2 Nominal cross-section(mm2): 1.5~630 0.6/1(1.2), 1.8/3(3.6) 3.6/6(7.2), 6/6(7.2)-6/10 (12) 8.7/10(12) 8.7/15(17.5) 12/20(24) 18/30(36) 21/35(40.5) 26/35(40.5) kV 3.2 The rated Temperature of Conductor a) The long-time operating temperature of conductor should not be higher than 90ºC b) If the core is in short circuit, short circuit temperature of conductor should not exceed 160ºCnot more than 5sec. 3.3 Ambient Temperature When installation, the ambient temperature should not be lower than 0ºC, otherwise the cable need be preheated. 3.4 Bending Radius Bending radius of single core cable is 20(d+D) ±5% Bending radius of multi-core cable is 15(d+D) ±5% d: Actual diameter of the conductor (mm) D: Actual outer diameter of cable sample (mm)
4. Specification of product.
Specification
Outer diameter
Nominal thickness of insulation
Diameter of steel wire
Nominal sheath thickness
Approx. Outer diameter of cable
Approx. Weight of cable
Ampacity of cable
Air
Soil
CU
AL
Cu
Al
Cu
Al
mm2
mm
mm
mm
mm
mm
kg/km
kg/km
A
A
A
A
4×4 RE
2.24
0.7
1.25
1.8
19.1
770
670
37
28
46
35
4×6 RE
2.76
0.7
1.25
1.8
20.3
916
772
47
37
56
46
4×10 CC
3.8
0.7
1.6
1.8
22.3
1148
895
64
47
76
56
4×16 CC
4.8
0.7
1.6
1.8
24.5
1472
1070
84
64
98
76
4×25 CC
6.0
0.9
1.6
1.8
27.5
1942
1317
115
84
126
98
4×35 CC
7.0
0.9
1.6
1.8
29.5
2386
1521
141
115
152
126
4×50 SM
8.0
1.0
2.0
1.9
32.9
3209
2036
172
141
181
152
4×70 SM
9.5
1.1
2.0
2.1
36.7
4197
2502
218
172
222
181
4×95 SM
11.0
1.1
2.0
2.3
40.5
5362
3016
269
218
267
222
4×120 SM
12.4
1.2
2.5
2.4
45.3
6908
3940
313
269
305
267
4×150 SM
13.8
1.4
2.5
2.6
50.0
8327
4683
359
313
344
305
4×185 SM
15.4
1.6
2.5
2.7
54.2
10044
5466
405
359
383
344
4×240 SM
17.5
1.7
2.5
2.9
60.4
12672
6666
451
405
442
383
4×300 SM
19.6
1.8
2.5
3.1
65.7
15302
7795
497
451
461
422
Specification
Outer diameter
Nominal thickness of insulation
Diameter of steel wire
Nominal sheath thickness
Approx. Outer diameter of cable
Approx. Weight of cable
Ampacity of cable
Air
Soil
CU
AL
Cu
Al
Cu
Al
mm2
mm
mm
mm
mm
mm
kg/km
kg/km
A
A
A
A
3×4+1×2.5 RE
2.24/1.78
0.7/0.7
1.6
1.8
17.4
649
558
37
28
46
35
3×6+1×4 RE
2.76/2.24
0.7/0.7
1.6
1.8
18.6
769
651
47
37
56
46
3×10+1×6 CC
3.8/2.76
0.7/0.7
1.6
1.8
20.3
989
763
64
47
76
56
3×16+1×10 CC
4.8/3.8
0.7/0.7
1.6
1.8
22.5
1270
906
84
64
98
76
3×25+1×16 CC
6.0/4.8
0.9/0.7
1.6
1.8
27.1
1857
1286
115
84
126
98
3×35+1×16 CC
7.0/4.8
0.9/0.7
1.6
1.8
29.3
2234
1483
141
115
152
126
3×50+1×25 SM
8.0/6.0
1.0/0.9
1.6
1.9
31.9
2828
1778
172
141
181
152
3×70+1×35 SM
9.5/7.0
1.1/0.9
2.0
2.0
36.3
3928
2420
218
172
222
181
3×95+1×50 SM
11.0/8.4
1.1/1.0
2.0
2.2
40.0
4956
2904
269
218
267
222
3×120+1×70 SM
12.4/10.0
1.2/1.1
2.5
2.3
44.4
6408
3760
313
269
305
267
3×150+1×70 SM
13.8/10.0
1.4/1.1
2.5
2.5
48.2
7456
4299
359
313
344
305
3×185+1×95 SM
15.4/11.5
1.6/1.1
2.5
2.6
52.4
9081
5062
405
359
383
344
3×240+1×120 SM
17.5/13.0
1.7/1.2
2.5
2.8
57.9
11292
6045
451
405
442
383
3×300+1×150 SM
19.6/14.5
1.8/1.4
2.5
3.0
63.0
13648
7106
497
451
461
422
Specification
Outer diameter
Nominal thickness of insulation
Diameter of steel wire
Nominal sheath thickness
Approx. Outer diameter of cable
Approx. Weight of cable
Ampacity of cable
Air
Soil
CU
AL
Cu
Al
Cu
Al
mm2
mm
mm
mm
mm
mm
kg/km
kg/km
A
A
A
A
5×4 RE
2.24
0.7
1.6
1.8
20.2
925
800
37
28
46
35
5×6 RE
2.76
0.7
1.6
1.8
21.6
1098
918
47
37
56
46
5×10 CC
3.8
0.7
1.6
1.8
23.8
1399
1083
64
47
76
56
5×16 CC
4.8
0.7
1.6
1.8
26.3
1791
1289
84
64
98
76
5×25 CC
6.0
0.9
1.6
1.8
33.5
2488
1706
115
84
126
98
5×35 CC
7.0
0.9
2.0
1.9
37.7
3339
2258
141
115
152
126
5×50 SM
8.0
1.0
2.0
2.0
38.2
3932
2468
172
141
181
152
5×70 SM
9.5
1.1
2.0
2.3
41.9
5122
3004
218
172
222
181
5×95 SM
11.0
1.1
2.5
2.4
47.9
7029
4096
269
218
267
222
5×120 SM
12.4
1.2
2.5
2.6
52.2
8487
4778
313
269
305
267
5×150 SM
13.8
1.4
2.5
2.7
55
10016
5460
359
313
344
305
5×185 SM
15.4
1.6
2.5
2.9
60.5
12218
6495
405
359
383
344
5×240 SM
17.5
1.7
2.5
3.1
66.5
15353
7845
451
405
442
383
5×300 SM
19.6
1.8
2.5
3.4
73.7
19419
10034
497
451
461
422
5. Construction.
Conductor shaped:RE=circular solid,CC=compacted circular stranded,SM=sector shaped stranded Conductors: Plain circular, compacted or shaped stranded copper or aluminium conductor Insulation: XLPE (cross-linked polyethylene) rated at 90°C Colour identification 1 Core : Red or Black 2 Cores : Red, Black 3 Cores: Red, Yellow, Blue 4 Cores: Red, Yellow, Blue, Black 5 Cores: Red, Yellow, Blue, Black, Green Above 5 Cores: Black Cores with White numerals The above identifying can be changed as order Assembly /Inner Sheath :Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted Armour:Aluminum/Galvanized Steel Wires, single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502. Outer Sheath:Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSZH, and CPE are available on request.