| Delivery Time | T+30 |
| Payment Terms | TT |
| Usage | Power,Distribution |
| Protection Level | IP56 |
| Frequency | 50Hz/60Hz |
| Structure | Cabinet |
| Shape | Rectangle |
| Product Type | Electrical Equipment |
| Brand Name | Dong Sheng Yuan |
| Model Number | 10kV Southern Power Grid Primary And Secondary Integrated Equipment (ring Network Box) |
| Place of Origin | Zhuhai, China |
View Detail Information
Explore similar products
Intelligent Metal Enclosed Electrical Distribution Cabinet Outdoor Substation
Intelligent Outdoor Prefabricated Substation Integrated Design Box Substation
Modular Prefabricated 10kV Box Type Substation IP55 Protection For Power Plants
European Style Prefabricated Box Type Substation IP33 Protection For Power
Product Specification
| Delivery Time | T+30 | Payment Terms | TT |
| Usage | Power,Distribution | Protection Level | IP56 |
| Frequency | 50Hz/60Hz | Structure | Cabinet |
| Shape | Rectangle | Product Type | Electrical Equipment |
| Brand Name | Dong Sheng Yuan | Model Number | 10kV Southern Power Grid Primary And Secondary Integrated Equipment (ring Network Box) |
| Place of Origin | Zhuhai, China | ||
| High Light | Box Type Electric Distribution Substation ,IP56 Protection Distribution Substation Box ,Customized Electric Distribution Substation | ||
Main technical parameter
Preassembled substation technical parameter table
| Serial number | Name | Unit | Technical specification |
| 1 | rated voltage | KV | 10/0.4(high voltage/low voltage) |
| 2 | maximum working voltage | KV | 12(high-pressure side) |
| 3 | rated frequency | HZ | 50 |
| 4 | rated capacity | KVA | 50-1600 |
| 5 | 1-minute power frequency withstand voltage | KV | 35 |
| 6 | lightning impulse voltage | KV | 75 |
| 7 | type of cooling | Oil immersed in self-cooling | |
| 8 | High voltage backup fuse breaking current | KA | 50 |
| 9 | Breaking the current of the plug-in fuse | KA | 2.5 |
| 10 | environment temperature | ºC | -35~+40 |
| 11 | Coil allowable temperature rise | ºC | 65 |
| 12 | No load voltage regulation | ±5%or±2x2.5% | |
| 13 | noise grade | db | 50 |
| 14 | level of protection | IP43 |
| Capacity kva | Voltage | no-load current | open circuit losses | impedance voltage | load loss |
|||||||
| high voltage | low voltage | S9 | S10 | S11 | S9 | S10 | S11 | 4.0 | S9 | S10 | S11 | |
| 50 | 10±5% ±2x2.5% |
0.4 | 2.0 | 1.9 | 0.75 | 0.17 | 0.15 | 0.12 | 0.87 | 0.83 | 0.87 | |
| 63 | 1.9 | 1.8 | 0.7 | 0.2 | 0.18 | 0.14 | 1.04 | 0.99 | 1.04 | |||
| 80 | 1.9 | 1.7 | 0.7 | 0.25 | 0.22 | 0.175 | 1.25 | 1.2 | 1.25 | |||
| 100 | 1.8 | 1.55 | 0.65 | 0.29 | 0.26 | 0.2 | 1.5 | 1.42 | 1.5 | |||
| 125 | 1.7 | 1.45 | 0.65 | 0.34 | 0.3 | 0.235 | 1.8 | 1.72 | 1.8 | |||
| 160 | 1.6 | 1.3 | 0.6 | 0.4 | 0.36 | 0.27 | 2.2 | 2.12 | 2.2 | |||
| 200 | 1.5 | 1.2 | 0.55 | 0.48 | 0.43 | 0.33 | 2.6 | 2.5 | 2.6 | |||
| 250 | 1.4 | 1.1 | 0.5 | 0.56 | 0.5 | 0.39 | 3.05 | 2.9 | 3.05 | |||
| 315 | 1.4 | 1.0 | 0.45 | 0.67 | 0.29 | 0.465 | 3.65 | 3.45 | 3.65 | |||
| 400 | 1.3 | 1.0 | 0.4 | 0.8 | 0.71 | 0.56 | 4.3 | 4.15 | 4.3 | |||
| 500 | 1.2 | 1.0 | 0.4 | 0.96 | 0.85 | 0.67 | 5.15 | 4.82 | 5.15 | |||
| 630 | 1.1 | 0.8 | 0.4 | 1.2 | 1.6 | 0.81 | 4.5 | 6.2 | 5.86 | 6.2 | ||
| 800 | 1.0 | 0.7 | 0.35 | 1.4 | 1.23 | 0.98 | 7.5 | 7.2 | 7.5 | |||
| 1000 | 1.0 | 0.6 | 0.3 | 1.7 | 1.5 | 1.15 | 10.3 | 9.8 | 10.3 | |||
| 1250 | 0.9 | 0.6 | 0.27 | 1.95 | 1.72 | 1.36 | 12.0 | 12.2 | 12.0 | |||
| Serial number | Name | Unit | Four-station loop load switch | Two-station load switch | |
| 1 | rated voltage | A | 630 | 315 | |
| 2 | Rated short-circuit closing current | KA | 31.5 | 31.5 | |
| 3 | rated short-time current | KA | 12.5 | 12.5 | |
| 4 | Rated short endurance time | S | 2 | 2 | |
| 5 | mechanical life | Next | 2000 | 2000 | |
| 6 | Lightning impulse withstand voltage peak full wave | Phase to phase | KV | 75 | 75 |
| 7 | isolating fracture | 85 | 85 | ||
| 8 | 1min power frequency withstand voltage | Phase to phase | KV | 42 | 42 |
| 9 | isolating fracture | 48 | 48 | ||
| 10 | Rated peak withstand current | KA | 31.5 | 31.5 | |
| Serial number | Three-phase transformer capacity(KVA) | XRNT rated current(A) | PRNT1 Overload protection rated current(A) |
| 1 | 30 | 10 | 6 |
| 2 | 50 | 16 | 8 |
| 3 | 80 | 16 | 10 |
| 4 | 100 | 20 | 15 |
| 5 | 125 | 25 | 15 |
| 6 | 160 | 31.5 | 25 |
| 7 | 200 | 40 | 25 |
| 8 | 250 | 50 | 40 |
| 9 | 315 | 63 | 40 |
| 10 | 400 | 63 | 40 |
| 11 | 500 | 80 | 50 |
| 12 | 630 | 100 | 50/65 |
| 13 | 800 | 125 | 65 |
| 14 | 1250 | 160 | 100 |
| 15 | 1600 | 200 | 140 |
Company Details
Business Type:
Manufacturer
Year Established:
2005
Total Annual:
1billion-2billion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Shenzhen Dongshengyuan Electrical Equipment Co., Ltd was established in 2005 with a registered capital of 50.6 million yuan. It is a modern high-tech company specializing in the research and development, manufacturing... Shenzhen Dongshengyuan Electrical Equipment Co., Ltd was established in 2005 with a registered capital of 50.6 million yuan. It is a modern high-tech company specializing in the research and development, manufacturing...
Get in touch with us