Packaging Details | WOODEN DRUMS |
Delivery Time | 30 DAYS |
Payment Terms | LC |
Supply Ability | 20KM/MONTH |
Place of Origin | CHINA |
Brand Name | XIN BAOFENG |
Certification | CE |
Model Number | YJV63 |
View Detail Information
Explore similar products
Three Core XLPE Insulated Middle Voltage Electric Cable Copper Conductor
12 / 20KV NA2XS / F 2Y Middle Voltage Electric Cable According To VDE 0276 - 620
COPPER / XLPE / SWA / PVC Middle Voltage Electric Cable 8.7KV / 15KV , 0.8mm
8.7kV / 15kV Middle Voltage Electric Cable , Extruded Copper XLPE SWA PVC Cable
Product Specification
Packaging Details | WOODEN DRUMS | Delivery Time | 30 DAYS |
Payment Terms | LC | Supply Ability | 20KM/MONTH |
Place of Origin | CHINA | Brand Name | XIN BAOFENG |
Certification | CE | Model Number | YJV63 |
High Light | Medium Voltage Wire , underground electrical cable |
Technical Particulars
|
Item |
Units |
Required |
Tendered |
|
|
|||
1. |
Voltage phase to phase (U to BS 6622:2007) |
kV |
33 |
33 |
2. |
Number of cores |
|
One |
One |
3. |
Conductor |
|
|
|
|
|
mm2 |
300 |
300 |
|
|
Copper |
Copper |
|
|
|
|
round |
|
|
mm |
|
20.6 |
|
|
0C |
|
≤40 |
|
4. |
Conductor screen |
|
|
|
|
|
|
|
Semi-conductive XLPE |
|
mm |
|
0.8 |
|
5. |
Insulation |
|
|
|
|
|
|
XLPE |
XLPE |
|
|
mm |
|
8.0 |
6. |
Core Screen |
|
|
|
|
|
|
|
Semi-conductive XLPE |
|
mm |
|
1.0 |
|
|
mm |
|
40.2 |
|
7. |
Metallic Layer |
|
|
|
|
|
|
|
Copper tape |
|
mm |
|
1 |
|
|
mm |
|
0.12 |
|
|
mm2 |
|
32 |
|
8. |
Metal sheath |
|
Not Applicable |
Not Applicable |
|
|
|
||
|
mm |
|||
|
mm |
|||
9. |
Lead alloy Sheath Composition |
|
||
|
|
% |
||
|
% |
|||
|
% |
|||
|
% |
|||
10. |
Aluminum Armour |
|
|
|
|
|
kPa |
|
165 |
|
|
|
172 |
|
|
|
kPa |
|
235 |
|
% |
|
99.9 |
|
|
0C |
|
25 |
|
11. |
Outer Cover |
|
|
|
|
|
|
|
PVC |
|
mm |
|
2.7 |
|
|
|
|
Additive |
|
|
|
|
Yes |
Yes |
12. |
Completed Cable |
|
|
|
|
|
mm |
|
54.4 |
|
kg |
|
5.5 |
|
|
m |
|
500 |
|
|
|
|
500 |
|
13. |
Cable Drums |
|
|
|
|
|
m |
|
2.2 |
|
m |
|
1.4 |
|
|
kg |
|
120 |
|
14. |
Conditions upon which current carrying |
|
|
|
|
Capacities laying in trefoil formation are based |
|
|
|
|
mm |
|
50 |
|
|
mm |
|
600 |
|
|
Deg. |
|
25 |
|
|
0C |
|
35 |
|
|
0C |
|
40 |
|
|
m |
|
1.2 |
|
|
|
Yes/No |
|
YES |
15. |
Maximum dielectric stress at the Sector screen (assumed smooth) |
kV/mm |
|
3.15 |
16. |
Minimum radius of bend around which can be laid |
|
|
|
|
|
m |
|
0.9 |
|
m |
|
0.9 |
|
|
m |
|
0.8 |
|
17. |
Nominal Internal diameter of pipes or ducts through which cable may be pulled. |
mm |
|
80 |
18. |
Maximum D.C Resistance of conductor per meter of cable 20 0C |
|
|
|
|
|
microhm |
|
60.1 |
|
|
microhm |
|
592 |
19. |
Maximum A.C Resistance of conductor per meter of cable at maximum conductor temperature |
microhm |
|
77.7 |
20. |
Insulation Resistance of cable per core |
|
|
|
|
|
MΩ |
|
10000 |
|
|
MΩ |
|
10000 |
21. |
Equivalent Star Reactance per meter of 3-phase Circuit at nominal frequency |
microhm |
|
0.227 |
22. |
Maximum Electrostatic capacitance per meter of cable |
pF |
|
246 |
23. |
Maximum Charging Current per core per meter of Cable at nominal voltage U0 |
A |
|
0.01 |
24. |
Current Carrying Capacity Based on the conditions specified |
|
|
|
|
Main Transformer Feeders |
A |
800 |
800 |
|
Line Feeders |
A |
400 |
400 |
25. |
Maximum Conductor Temperature |
|
|
|
|
|
0C |
|
90 |
|
|
0C |
|
90 |
|
|
0C |
|
90 |
26. |
Conductor short circuit current carrying capacity for one second, cable loaded as above prior to short circuit and final conductor temperature of 250 0C
|
kA |
25 |
25 |
27. |
Metallic layer earth faulty current Carrying Capacity for one second, cable loaded as above Prior to earth fault and final screen temperature |
kA |
16 |
16 |
0C |
|
250 |
||
28. |
Maximum dielectric loss of cable per meter of three phase circuit when laid direct in the ground at nominal voltage Uo, nominal frequency and operating oil pressure at maximum conductor Temperature |
W/m |
|
0.03 |
29. |
Maximum dielectric loss angle of charging VA of Cable when laid direct in the ground at nominal voltage ,Uo,normal frequency at |
tan d |
|
0.001 |
|
|
|
|
0.001 |
|
tan d |
|
0.001 |
|
30. |
Maximum dielectric loss angle of charging VA of cable at normal frequency conductor temperature of 20 0C at |
|
|
|
|
|
tan d |
|
0.001 |
|
tan d |
|
0.002 |
|
|
tan d |
|
0.002 |
|
31. |
Metallic layer loss (including amour if applicable) of cable per meter of three-phase circuit at nominal voltage Uo and normal frequency at the circuit rating stated above |
W |
|
5.2 |
32. |
Horizontal distance between cable supporting racks |
|
|
1000mm |
33. |
Creepage distance of sealing and porcelain |
|
|
|
|
Specified |
mm |
|
15 |
|
Guaranteed |
mm |
|
15 |
34. |
Type test certificate |
|
Yes |
Yes |
35. |
Partial discharge at 2U0 |
pC |
<=5 |
<=5 |
Cable size and structure of sections
CU/SC/XLPE/SC/CTS/PVC/AWA/PVC 1×300mm2
Construction |
Thickness (mm) |
Diameter (mm) |
1---Copper conductor |
-- |
20.6(+0.1,-0.1) |
2---Copper screen |
0.8 |
22.3 |
3---XLPE Insulation |
8.0 |
38.2(+0.5,-0.5) |
4---Insulation screen |
1.0 |
40.2 |
5---Copper tape screen |
0.12 |
40.6 |
6---PVC inner sheath |
1.4 |
43.4 |
7---Aluminum wire amour+ aluminum tape |
2.5+0.3 |
49.0 |
8---PVC outer sheath |
2.7 |
54.4(+2.0,-2.0) |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1982
Total Annual:
> 100,000,000
Employee Number:
>1000
Ecer Certification:
Active Member
Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...
Get in touch with us