China 33KV Single Core Middle Voltage Electric Cable 300MM2 COPPER / XLPE / AWA / PVC
China 33KV Single Core Middle Voltage Electric Cable 300MM2 COPPER / XLPE / AWA / PVC

  1. China 33KV Single Core Middle Voltage Electric Cable 300MM2 COPPER / XLPE / AWA / PVC

33KV Single Core Middle Voltage Electric Cable 300MM2 COPPER / XLPE / AWA / PVC

  1. MOQ: 1000METERS
  2. Price: USD 6
  3. Get Latest Price
Packaging Details WOODEN DRUMS
Delivery Time 30 DAYS
Payment Terms LC
Supply Ability 20KM/MONTH
Place of Origin CHINA
Brand Name XIN BAOFENG
Certification CE
Model Number YJV63

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details WOODEN DRUMS Delivery Time 30 DAYS
Payment Terms LC Supply Ability 20KM/MONTH
Place of Origin CHINA Brand Name XIN BAOFENG
Certification CE Model Number YJV63
High Light Medium Voltage Wire underground electrical cable

Technical Particulars

 

 

Item

 

Units

Required

Tendered

 

 

1.

Voltage phase to phase (U to BS 6622:2007)

kV

33

33

2.

Number of cores

 

One

One

3.

Conductor

 

 

 

 

  • Cross sectional area

mm2

300

300

  • Material

 

Copper

Copper

  • Design

 

 

round

  • Overall Diameter

mm

 

20.6

  • Welding or soldering temp

0C

 

≤40

4.

Conductor  screen

 

 

 

 

  • Material

 

 

Semi-conductive XLPE

  • Thickness Approx:

mm

 

0.8

5.

Insulation

 

 

 

 

  • Material

 

XLPE

XLPE

 

  • Thickness Approx:

mm

 

8.0

6.

Core Screen

 

 

 

 

  • Material

 

 

Semi-conductive XLPE

  • Thickness  ,approx.

mm

 

1.0

  • Diameter over screen

mm

 

40.2

7.

Metallic Layer

 

 

 

 

  • Material

 

 

Copper tape

  • No. of Wires or Tapes

mm

 

1

  • Size. of wire or Tape

mm

 

0.12

  • Cross Section

mm2

 

32

8.

Metal sheath

 

 

Not Applicable

 

Not Applicable

 

  • Material

 

  • Nominal Thickness

mm

  • External Diameter

mm

9.

Lead alloy Sheath Composition

 

 

  • Tin

%

  • Cadmium

%

  • Antimony

%

  • Lead

%

10.

Aluminum Armour

 

 

 

 

  • Maximum Working Hoop

kPa

 

165

  • Stress

 

 

172

 

  • 0.1% Proff Stress

kPa

 

235

  • Purity

%

 

99.9

  • Plumbing Temperature

0C

 

25

11.

Outer Cover

 

 

 

 

  • Material

 

 

PVC

  • Minimum Average Thickness

mm

 

2.7

  • Type of termite Repellent

 

 

Additive

 

  • UV Protected

 

Yes

Yes

12.

Completed Cable

 

 

 

 

  • Overall Diameter, approx

mm

 

54.4

  • Weight per Meter

kg

 

5.5

  • Drum Length

m

 

500

  • Nominal

 

 

500

13.

Cable Drums

 

 

 

 

  • Overall Diameter

m

 

2.2

  • Width

m

 

1.4

  • Weight Loaded

kg

 

120

14.

Conditions upon which current carrying

 

 

 

 

Capacities laying in trefoil formation are based

 

 

 

  • Axial spacing between phase cable

mm

 

50

  • Axial spacing between circuits

mm

 

600

  • Soil thermal resistively

Deg.

 

25

  • Ground Temperature

0C

 

35

  • Air Temperature

0C

 

40

  • Burial depth

m

 

1.2

 

  • Type of earth bonding :Single Point

 

Yes/No

 

YES

15.

Maximum dielectric stress at the Sector screen (assumed smooth)

kV/mm

 

3.15

16.

Minimum radius of bend around which can be laid

 

 

 

 

  • Laid direct

m

 

0.9

  • In ducts

m

 

0.9

  • In Air

m

 

0.8

17.

Nominal Internal diameter of pipes or ducts through which cable may be pulled.

mm

 

80

18.

Maximum D.C Resistance of conductor per meter of cable 20 0C

 

 

 

 

  • Of conductor

microhm

 

60.1

 

  • Of metallic layers

microhm

 

592

19.

Maximum A.C Resistance of conductor per meter of cable at maximum conductor temperature

 

microhm

 

77.7

20.

Insulation Resistance of cable per core

 

 

 

 

  • 20 0C

 

10000

 

  • At max. rated temp

 

10000

21.

Equivalent Star Reactance per meter of 3-phase Circuit at nominal frequency

 

microhm

 

0.227

22.

Maximum Electrostatic capacitance per meter of cable

 

pF

 

246

23.

Maximum Charging Current per core per meter of Cable at nominal voltage U0

 

A

 

0.01

24.

Current Carrying Capacity Based on the conditions specified

 

 

 

 

Main Transformer Feeders

A

800

800

 

Line Feeders

A

400

400

25.

Maximum Conductor Temperature

 

 

 

 

  • Laid direct in Ground

0C

 

90

 

  • Drawn into ducts

0C

 

90

 

  • Erected in air

0C

 

90

26.

Conductor short circuit current carrying capacity for one second, cable loaded as above prior to short circuit and final conductor temperature of 250 0C

 

 

kA

 

25

25

27.

Metallic layer earth faulty current Carrying Capacity for one second, cable loaded as above Prior to earth fault and final screen temperature

kA

16

16

0C

 

250

28.

Maximum dielectric loss of cable per meter of three phase circuit when laid direct in the ground at nominal voltage Uo, nominal frequency and operating oil pressure at maximum conductor Temperature

 

W/m

 

0.03

29.

Maximum dielectric loss angle of charging VA of Cable when laid direct in the ground  at nominal voltage ,Uo,normal frequency at

 

tan d

 

0.001

 

  • A Conductor temperature of 20 0C

 

 

0.001

  • Maximum Conductor Temperature

 

tan d

 

0.001

30.

Maximum dielectric loss angle of charging VA of cable at normal frequency conductor temperature of 20 0C at

 

 

 

 

  • 50% rated voltage Uo

tan d

 

0.001

  • 125% rated voltage Uo

tan d

 

0.002

  • 200% rated voltage Uo

tan d

 

0.002

31.

Metallic layer loss (including amour if applicable) of cable per meter of three-phase  circuit at nominal voltage Uo and normal frequency at the circuit rating stated above

 

W

 

5.2

32.

Horizontal distance between cable  supporting racks

 

 

1000mm

33.

Creepage distance of sealing and porcelain

 

 

 

 

Specified

mm

 

15

 

Guaranteed

mm

 

15

34.

Type test certificate

 

Yes

Yes

35.

Partial discharge at 2U0

pC

<=5

<=5

 

 

 

 

 

 

 

 

Cable size and structure of sections

 

CU/SC/XLPE/SC/CTS/PVC/AWA/PVC 1×300mm2

Construction

Thickness (mm)

Diameter (mm)

1---Copper conductor

--

20.6(+0.1,-0.1)

2---Copper screen

0.8

22.3

3---XLPE Insulation

8.0

38.2(+0.5,-0.5)

4---Insulation screen

1.0

40.2

5---Copper tape screen

0.12

40.6

6---PVC inner sheath

1.4

43.4

7---Aluminum wire amour+ aluminum tape

2.5+0.3

49.0

8---PVC outer sheath

2.7

54.4(+2.0,-2.0)

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1982

  • Total Annual:

    > 100,000,000

  • Employee Number:

    >1000

  • Ecer Certification:

    Active Member

Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...

+ Read More

Get in touch with us

  • Reach Us
  • Hebei New Baofeng Wire & Cable Co.,Ltd
  • Jinghe Hi-tech Industrial Zone, Hejian City, Hebei province,China
  • http://www.nbf-powercable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement