China factories

China factory - HUATEC  GROUP  CORPORATION

HUATEC GROUP CORPORATION

  • China,Beijing ,Beijing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Circular Magnetic Particle Flaw Detector Customized
China Circular Magnetic Particle Flaw Detector Customized

  1. China Circular Magnetic Particle Flaw Detector Customized
  2. China Circular Magnetic Particle Flaw Detector Customized
  3. China Circular Magnetic Particle Flaw Detector Customized

Circular Magnetic Particle Flaw Detector Customized

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union,Paypal
Supply Ability 500Pcs
Delivery Time 1-4working days
Packaging Details Standard export package
Input current 8A, the standby current is 0.5A;
Magnetizing current 8A (8A * 400T = 3200AT);
Demagnetization current 8-0A;
Coil size 300mm, 400 turns in total;
Temporary load rate > 30%;
Brand Name HUATEC
Model Number HCDX-C300
Certification ISO, CE, GOST
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,Paypal Supply Ability 500Pcs
Delivery Time 1-4working days Packaging Details Standard export package
Input current 8A, the standby current is 0.5A; Magnetizing current 8A (8A * 400T = 3200AT);
Demagnetization current 8-0A; Coil size 300mm, 400 turns in total;
Temporary load rate > 30%; Brand Name HUATEC
Model Number HCDX-C300 Certification ISO, CE, GOST
Place of Origin China
High Light circular magnetic particle flaw detectorcustomized magnetic particle flaw detector

I. main parameter

 

1,Input current: 8A, determined according to the set values of magnetization and demagnetization, the standby current is 0.5A;

2, Power supply: AC200-240V 50 / 60Hz;

3, Magnetizing current: 8A (8A * 400T = 3200AT);

4, Central magnetic field: Max 110Gs;

5, Demagnetization current: 8-0A;

6, Coil size: Φ 300mm, 400 turns in total;

7, Temporary load rate:> 30%;

 

II. Function introduction

 

1, Magnetization - start the electromagnetic field to magnetize the workpiece;

2, Demagnetization - demagnetization field starts to demagnetize the workpiece;

3, Over temperature alarm - the coil has a built-in 75 ℃ temperature sensor. When the set temperature is exceeded, it enters the protection state;

 

III. Installation and commissioning

 

Installation:

1. The equipment shall be installed in a dry environment without metal dust, corrosive gas and inflammable and explosive articles;

2. The temperature of surrounding medium shall not be lower than - 10 ℃ and not higher than + 40 ℃;

3. The relative humidity of the air shall not be greater than 85%;

4. The pipe and wire connection between the installation equipment and each auxiliary facility shall be connected according to the indication sign and plug base;

5. Power supply (power supply, air source, etc., according to equipment installation environment and operation conditions), and the equipment shell is reliably grounded;

 

Commissioning:

1. After the equipment is installed in place, first check whether all connecting wires and fastening screws are loose and fall off;

2. Use instruments to measure whether the voltage at the upper end of the main switch of the machine meets the requirements of equipment installation environment and operation conditions;

3. Check each function action, manually press or toggle each function switch, and each function action of the equipment shall be executed accordingly;

4. Demagnetization effect inspection: check whether the residual magnetism after demagnetization meets the requirements;

5. After passing the commissioning and inspection, the equipment can be put into production.

 

IV. Routine maintenance

After the equipment is used, the following operations must be carried out:

1. Turn off the power switch and cut off the power supply of the equipment;

2. Cut off the main switch of external power supply;

3. Clean up the oil stain on the coil surface and keep the whole equipment clean;

4. Check the circuit connecting line, cable and fastener for looseness and aging within one month;

5. Check whether the concentration of magnetic suspension meets the standard every day;

6. Neutral washing must be used to clean the oil stain on the surface of the equipment;

7. If the shell is damaged, it is forbidden to continue to use;

 

V. Flaw detection principle

 

Principles of electromagnetism

 

The magnetizing current forms an electromagnetic field through the surface of ferromagnetic workpiece (AC and half wave DC have skin effect). The existence of defects will cut off the magnetic line of force, form a leakage magnetic field and adsorb magnetic particles. Magnetic particles accumulate to form magnetic marks. The existence of defects can be judged by observing magnetic marks (magnetic marks are actually enlarged defects).

 

 

Residual method

Different from the continuous method, the workpiece is magnetized first, then soaked in magnetic suspension for a period of time, and magnetic particles are absorbed by the remanence of the workpiece to form magnetic marks. This method is limited to low requirements, single-direction and residual magnetic induction intensity of the workpiece Br≥ 0.8t.

 

Remanence refers to the size of the remaining magnetic field after flaw detection, usually in Gauss (Gs), millitesla (mT), ampere/meter (A/m) as the unit. 1mT=10Gs,80A/m=1Gs, the size of remanence is related to the workpiece material.

Magnetic suspension (magnetic powder should be fully stirred and suspended in the liquid before flaw detection.)

 

Magnetic powder is processed to reach a certain grain size requirements of iron powder. General magnetic particle flaw detection wet method can be more than 400 mesh.

 

Fluorescent magnetic powder is in ordinary magnetic powder plus a chemical substance, usually called fluorescent brilliance agent, added after the fluorescent lamp irradiation can emit fluorescent light, can increase flaw detection sensitivity, convenient observation.

 

Oil-magnetic suspension formula :(or 3# oil-based magnetic powder flaw detection carrier)

 

(winter) transformer oil (25#) : odorless kerosene = 1:3

 

(summer) transformer oil (25#) : odorless kerosene = 1:2 -- 1:3

 

Mixed oil: ordinary non-fluorescent magnetic powder =1000ml: 10-20g

 

Mixed oil: fluorescent magnetic powder =1000ml: 2g-3g

 

Water magnetic suspension formula: compound water-based fluorescent magnetic powder with a small amount of water to stir the magnetic powder into paste, then add enough water (compound suspension powder has contained dispersant, defoaming agent, rust inhibitor components), non-compound fluorescent magnetic powder ratio is as follows;

 

dispersant 21g Rust inhibitor 21g

Defoaming agent 21g Fluorescent magnetic particle 2g—3g

Water 1L

Sensitivity

Sensitivity refers to the precision of magnetic particle flaw detection, usually through the NATIONAL standard TYPE A test to detect. Type A standard test is usually referred to as sensitivity test. Type A standard test sheet has three kinds of sensitivity: high, medium and low. The smaller the fraction value in type A, the higher the effective magnetic induction intensity that can display magnetic mark is required. (A-15/100, A-30/100, A-60/100, A-7/50, A-15/50, A-30/50, six scores, the highest sensitivity of 1# test film includes A-15/100, A-7/50. 2# Test tablets have moderate sensitivity, suitable for most industries, including A-30/100, A-15/50. 3# test tablets have the lowest sensitivity, including A-60/100 and A-30/50.)

Method of use of standard sensitivity test piece (suitable for continuous method), usually using type A standard test piece 2#(30/100 or 15/50) for the selection of magnetization current for flaw detection.

 

The artificial defects can be clearly displayed on the smooth surface of the test piece by tightly fitting the surface of the test piece with artificial defects with the workpiece under test, slowly flowing magnetic suspension through the workpiece and applying appropriate magnetization current (adjusting circumferential direction and longitudinal direction respectively). The value of magnetization current is the appropriate magnetization specification.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2007

  • Total Annual:

    500000-1000000

  • Employee Number:

    35~50

  • Ecer Certification:

    Verified Supplier

HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified... HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified...

+ Read More

Get in touch with us

  • Reach Us
  • HUATEC GROUP CORPORATION
  • 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
  • MsShifen Yuan
  • 8610 82921131,8613910983110
  • https://www.ndttester.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement