China factories

Chat Now Send Email
China factory - ESTEL (GUANGDONG) TECHNOLOGY CO., LTD.

ESTEL (GUANGDONG) TECHNOLOGY CO., LTD.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
China Communication Inverter Module with 3 Ports and Intelligent Monitoring for

  1. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
  2. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
  3. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
  4. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
  5. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for
  6. China Communication Inverter Module with 3 Ports and Intelligent Monitoring for

Communication Inverter Module with 3 Ports and Intelligent Monitoring for

  1. MOQ: 100
  2. Price: USD50-USD500
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 5000
Delivery Time 20~35
Packaging Details carton case
Applications Industiral Applications
Industrial Ac Input Single phase for each rectifiers
Storage Temperature -40 to +85
Package cartons
Inputvoltage AC 220V/380V
Lock Anti-theft three point lock
Output Power 6400W
Input Capacity 1×63A/2P
Ups Switch Time <12ms during grid failure
Lead Time 8 weeks
Quality Guarantee 24 months
Cabinet Lock anti-theft three point lock
Brand Name ESTEL
Model Number Communication Inverter Module
Certification CE UL FCC
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 5000
Delivery Time 20~35 Packaging Details carton case
Applications Industiral Applications Industrial Ac Input Single phase for each rectifiers
Storage Temperature -40 to +85 Package cartons
Inputvoltage AC 220V/380V Lock Anti-theft three point lock
Output Power 6400W Input Capacity 1×63A/2P
Ups Switch Time <12ms during grid failure Lead Time 8 weeks
Quality Guarantee 24 months Cabinet Lock anti-theft three point lock
Brand Name ESTEL Model Number Communication Inverter Module
Certification CE UL FCC Place of Origin China
High Light 3-port communication inverter moduleintelligent monitoring telecom power systemnetwork management inverter with warranty

Communication Inverter Module with 3 Ports and Intelligent Monitoring for Network Management

 

 

 

Product Overview

 

 

The IP123000G2A communication inverter module is built with three ports: AC input, AC output, and DC input/output. Its core purpose is to maintain a stable AC supply to critical loads by intelligently selecting the available power source:

  • When utility AC is normal: the module processes the AC supply through rectification and delivers a stable AC output to the load.

  • When utility AC is unavailable: the module automatically switches to DC input and converts DC power into AC output, ensuring power continuity for essential equipment (switching strategy depends on system configuration).

 

It complies with relevant electrical standards and industry regulations, and provides network management + intelligent monitoring for modern telecom/ICT infrastructure. It also supports parallel operation of up to 3 modules, enabling capacity expansion and higher availability designs.

 

 


 

 

Key Features

 

  • Automatic AC/DC source transfer: AC-first operation with DC backup inversion when AC fails, reducing downtime risk.

  • Three-port integrated design: AC input/output and DC input/output in one module—simplifies system integration and maintenance.

  • Network management & smart monitoring: remote visibility of operating status, alarms, and key parameters (exact items depend on the monitoring protocol and system).

  • Standards compliance + EMC readiness: designed to meet electrical standards and industry requirements, suitable for telecom-grade deployment.

  • Up to 3-module parallel operation: supports load sharing and scalable power architecture; can be used for redundancy (e.g., N+1) depending on system design.

  • Harsh-environment capability: wide temperature/humidity range and altitude adaptability for outdoor sites and edge facilities.

 

 


 

 

Main Specifications

 

 

Environmental Conditions

  • Operating temperature: -20°C to +75°C (power derating from 45°C to 75°C)

  • Storage temperature: -40°C to +75°C

  • Relative humidity: 5% to 95%RH, non-condensing

  • Altitude: ≤ 4000 m (temperature decreases by 1°C per 200 m elevation as a reference for high-altitude adaptation)

 

Electrical Input (Single-Phase)

  • Input mode: TT/TNIT (single-phase input)

  • Input voltage range: 176 Vac to 265 Vac

  • Rated input voltage: 220 Vac

  • Maximum input voltage: 300 Vac

  • Maximum input current: 22 A

  • Starting inrush current: ≤ 15 A


 

 

Typical Application Scenarios

 

  • Telecom sites / base stations: ensuring uninterrupted AC supply for transmission equipment, switches, routers, and site controllers.

  • Network and edge infrastructure: micro data rooms, edge cabinets, distributed nodes—especially where remote monitoring reduces on-site visits.

  • Private networks & industrial communications: rail transit, public safety/emergency networks, power-utility communications—where continuity and compliance matter.

  • Battery-backed critical loads: systems using DC battery strings or DC bus for backup power, requiring reliable DC-to-AC conversion during mains outages.


 

 

Installation & Parallel Operation (Practical Guidance)

 

Mounting location: typically installed inside a telecom power rack/cabinet. Ensure adequate ventilation and keep away from direct heat sources and moisture. Use the manufacturer-defined mounting rails/holes and torque specs.

Wiring principles (typical best practice):

  1. Provide compliant protection upstream of AC input (breaker/fuse and grounding).

  2. Connect AC output to the protected load bus or distribution unit.

  3. Connect DC input/output to the DC bus or battery system per polarity and cable sizing requirements.

  4. Use reliable grounding and route monitoring/communication cables with shielding and separation from power cables to reduce EMI.

 

 

Parallel operation (up to 3 modules):

 

  • Use the same model/version for parallel sets.

  • Follow the specified parallel/communication wiring and addressing rules (if applicable).

  • Keep cable lengths and impedance as consistent as possible to support stable load sharing.

  • Consider redundancy planning (e.g., capacity margin or N+1) based on site criticality.

 

 


 

 

Operational Notes / Precautions

 

  • Derating above 45°C: in hot sites, avoid sustained full-load operation without sufficient airflow; keep filters/heatsinks clean.

  • Non-condensing humidity requirement: prevent condensation in environments with large temperature swings; consider cabinet heaters/dehumidification if needed.

  • High altitude considerations: reduced air density impacts cooling; reserve power margin and validate thermal performance near 4000 m.

  • Grid fluctuation & surge protection: if the supply can approach 300 Vac or is lightning-prone, implement appropriate surge protection and upstream power conditioning.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    1999

  • Total Annual:

    15000000‌-20000000‌

  • Employee Number:

    300~350

  • Ecer Certification:

    Verified Supplier

Introduction  ESTEL is a professional manufacturer and solution provider for a wide range of telecom power equipment - Rectifier Power Systems, Hybrid Energy Telecom Power Systems, Integrated Outdoor Telecom Cabinets, Smart Power Distribution Units, and Surge Protection Devices. Its manuf... Introduction  ESTEL is a professional manufacturer and solution provider for a wide range of telecom power equipment - Rectifier Power Systems, Hybrid Energy Telecom Power Systems, Integrated Outdoor Telecom Cabinets, Smart Power Distribution Units, and Surge Protection Devices. Its manuf...

+ Read More

Get in touch with us

  • Reach Us
  • ESTEL (GUANGDONG) TECHNOLOGY CO., LTD.
  • 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
  • https://www.outdoortelecomcabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement