Payment Terms | L/C, D/A, T/T, Western Union |
Supply Ability | 5000pcs/Month |
Delivery Time | 3-5Workingdays |
Packaging Details | Box |
Operating temperature range | -40~+50℃ |
Recommended storage temperature | 0~20℃ |
Working pressure range Atmospheric pressure | ± 10% |
Operating humidity range | 15 - 90% RH non-condensing |
Expected service life | 2 years in air |
Long-term output drift | <5% signal loss per year |
Brand Name | CITY |
Model Number | MICROceL HS ACU01-U00 BW SR-H-MC |
Place of Origin | UK |
View Detail Information
Explore similar products
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
Product Specification
Payment Terms | L/C, D/A, T/T, Western Union | Supply Ability | 5000pcs/Month |
Delivery Time | 3-5Workingdays | Packaging Details | Box |
Operating temperature range | -40~+50℃ | Recommended storage temperature | 0~20℃ |
Working pressure range Atmospheric pressure | ± 10% | Operating humidity range | 15 - 90% RH non-condensing |
Expected service life | 2 years in air | Long-term output drift | <5% signal loss per year |
Brand Name | CITY | Model Number | MICROceL HS ACU01-U00 BW SR-H-MC |
Place of Origin | UK | ||
High Light | SR-H-MC ,Hydrogen Gas Sensor ACU01-U00 |
SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemistry
Hydrogen sulfide gas sensor (H2S sensor) MICROceL HS features:
1. Robust hydrogen sulfide sensor for portable life safety applications
2.small size
Specification:
Product Type | H2S Gas Sensor |
Working principle | Three-electrode electrochemistry |
Measuring range | 0-100 ppm CO |
Overload | 1000 ppm CO |
Filter | Reduce the TLV level of interfering gases |
Sensitivity | 0.105 ± 0.025 μA/ppm |
T50 response time | <10 seconds at 20°C |
Typical T90 response time | 25~40 seconds |
Baseline shift (clean air) | -2~+1 ppm CO equivalent |
Zero offset (+20°C~ +40°C) | <0.2 ppm CO equivalent |
CITY is designed to operate in a variety of environments and harsh conditions. However, it is important to avoid exposure to high concentrations of solvent vapors when storing, loading the instrument, and working.
When using the sensor on a printed circuit board (PCB), a degreaser should be used before mounting the sensor. Do not stick directly on or near the CiTiceL as the solvent may cause the plastic to crack.
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!