Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"0393 0104 Carbon Monoxide Gas Sensor Mainly Used In Industrial Fields Such As","imgUrl":"https:\/\/img.chinax.com\/nimg\/1f\/11\/a4ab516c6daebad6296c3897eb24-200x200-1\/0393_0104_carbon_monoxide_gas_sensor_mainly_used_in_industrial_fields_such_as.jpg","attrs":{"Model Number":"0393 0104","Place of Origin":"Germany","Minimum Order Quantity":"1","Price":"Negotiable"}}
{"title":"H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/de\/2c3edff3ffc6e6ffe104cf9106a5-200x200-1\/h2s_ah_high_current_hydrogen_sulfide_sensor_for_portable_devices_0_03_ppm_resolution_2_year_service_life.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-AH","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In","imgUrl":"https:\/\/img.chinax.com\/nimg\/3b\/76\/709cbd27e1256f889d1932c83ee4-200x200-1\/nh3_b1_four_electrode_electrochemical_ammonia_sensor_28nh3_sensor_29_is_used_in_ammonia_gas_transmitter.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NH3-B1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor","imgUrl":"https:\/\/img.chinax.com\/nimg\/93\/a5\/26fe289e29911b4d52b464ddf558-200x200-1\/h2s_b4_high_resolution_hydrogen_sulfide_sensor_28h2s_sensor_29_is_used_to_monitor_trace_hydrogen_sulfide_in_air_quality.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-B4","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide","imgUrl":"https:\/\/img.chinax.com\/nimg\/8e\/e9\/481f097eb9ce0c098d1848168c96-200x200-1\/no2_a1_nitrogen_dioxide_sensor_28portable_no2_sensor_29_for_nitrogen_dioxide_portable_monitor.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NO2-A1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection","imgUrl":"https:\/\/img.chinax.com\/nimg\/ad\/40\/82c7966c902dc6957c764eec744c-200x200-1\/no_a1_nitric_oxide_gas_sensor_no_sensor_used_for_automobile_exhaust_detection.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
0393 0104 Carbon Monoxide Gas Sensor Mainly Used In Industrial Fields Such As Smoke Analysis And Environmental Monitoring
Key Product Advantages:
Reliable Compatibility: It is specially customized for testo 350 series flue gas analyzers. The size and electrical parameters are perfectly matched with the equipment, enabling seamless connection without additional adaptation operations.
Hydrogen Interference Resistance: The integrated hydrogen compensation technology makes it suitable for flue gas environments containing hydrogen components (such as industrial combustion systems using mixed fuels). It can filter out the interference of hydrogen on CO detection and improve measurement reliability.
Convenient Replacement: In line with testo's consistent design concept of easy maintenance for industrial sensors, users can complete the replacement by plugging and unplugging on - site, without relying on professional maintenance teams, thus reducing equipment downtime.
Factory - Calibrated Quality: It adheres to testo's strict industrial sensor production standards. It has undergone strict calibration before leaving the factory. After installation, it can be put into use quickly, eliminating the need for complicated on - site calibration procedures.
Supplementary Information:
Pricing Reference: The listed price on the industrial supply platform is about 897 US dollars. The actual price may fluctuate due to factors such as purchase volume, regional sales policies and supply channels.
Usage Notes: It is only a replacement part. To initially activate the CO - H₂ measurement function of the testo 350 analyzer, you need to use the dedicated retrofit sensor (order number: 0554 2104) first.
Application Scenarios: It is widely used in flue gas detection scenarios such as industrial boilers, combustion furnaces and thermal power systems. It is an important accessory to ensure that enterprises can effectively monitor CO emissions.
It is a dedicated replacement sensor rather than an initial retrofit sensor. It is used to replace the old or faulty CO - H₂ sensor in matched analyzers to ensure continuous and stable carbon monoxide measurement.
Compatible Devices
Specifically compatible with testo 350 and testo 350 Blue Edition flue gas analyzers. It is an essential spare part for maintaining the CO measurement function of these analyzers.
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...