China factories

Chat Now Send Email
China factory - ShenzhenYijiajie Electronic Co., Ltd.

ShenzhenYijiajie Electronic Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive
China YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive

  1. China YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive
  2. China YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive

YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1500
Delivery Time 5-8 days
Packaging Details Canned
Operating Principle 4-Electrode electrochemical
Measurement Range 0-300 ppb NO
Maximum Overload 500 ppb NO
Housing Material 20% glass filled polypropylene
Colour WhiteWeight 16g (approx.)
Range ContinuousIntermittent
Brand Name YJJ
Model Number MNO-LO AB770-40Z MNOLO
Place of Origin Britain

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1500
Delivery Time 5-8 days Packaging Details Canned
Operating Principle 4-Electrode electrochemical Measurement Range 0-300 ppb NO
Maximum Overload 500 ppb NO Housing Material 20% glass filled polypropylene
Colour WhiteWeight 16g (approx.) Range ContinuousIntermittent
Brand Name YJJ Model Number MNO-LO AB770-40Z MNOLO
Place of Origin Britain
High Light electrochemical nitric oxide sensorexhaled nitric oxide detectorMNOLO gas sensor with warranty

Product Description:

YJJ MNO-LO AB770-40Z MNOLO Electrochemical Nitric Oxide Sensor Detects Excessive Exhaled Nitric Oxide

 

Features:

Technical Specifications
MEASUREMENT
Operating Principle 4-electrode electrochemical
Measurement Range 0-300 ppb NO
Maximum Overload500 ppb NO
FilterTo remove acid gases
Sensitivity0.7-1.7 nAvppb(see note)7 .17 mVb when used with
recommended circuitry
0-100 ppb NO equivalent
+3000 mV
<24 hours to fully stabilise
(See Operating Principles)
NO response is linear but may
be influenced by the humidity
zero offset
OffsetBaselineStart-up Time from Open CircuitRepeatabilityLiearity
ELECTRICAL
Bias Voltage | +350 mV
+5% of linear region (aboveResolutionzero offset level) when usingrecommended circuitny

MECHANICAL
Housing Material 20% glass filled polypropylene
Colour WhiteWeight 16g (approx.)
Orientation Any

ENVIRONMENTAL
Typical Applications
Operating Temperature
Range:ContinuousIntermittent
Operating Pressure Range
Operating Humidity
Range:ContinuousIntermittent
Breath Analysis
10°C to 30°C0°C to 35°C1 atm ± 10%
25% to 75% RH non-condensing
0% to 100% RH non-condensing
INTRINSIC SAFETY DATA
Maximum at 1000 ppb 0.1 mA
Maximum o/c Voltage 1.3 V
Maximum s/c Current <1.0 A

Poisoning
CiTiceLs electrochemical sensors are designed for operation in a wide range of environments and harshconditions, However it's important that exposure to high concentrations of solvent vapours is avoided, bothduring storage, fiting into instruments, and operation. When using sensors with printed circuit boards (PCBs).deareasing agents should be used before the sensor is fited, Do not glue directy on or near the sensor as thesolvent may cause crazing of the plastic.
Cross Sensitivity Table
Whilst CiTicels are designed to be highly specific to the gas they are intended to measure, they will still respondto some degree to various other gases. The table below is not exclusive and other gases not included in the tablemay still cause a sensor to react.
IMPORTANT NOTE : The cross sensitivity data shown below does not form part of theproduct specification and is supplied for guidance only. Values quoted are based ontests conducted on a small number of sensors and any batch may show significantvariation. For the most accurate measurements, an instrument should be calibratedusing the gas underinvestigation.
Gas
Nitrogen, N.
Carbon Dioxide,CO.Carbon Monoxide,CO
Reading (ppb equivalent)
Concentration Used

Test criteria :Baseline gas 50% RH NO filtered airCross sensitive gas 0% RH
Cross sensitivity data was calculated reference to the standard regime (baseline 50%Rh fitered cylinder air,50 & 100 ppb NO @ 20% RH),. Due to the effect of RH on the MNo-LO sensor, cross sensiiviies have beendetermined using 0%RH test gas.

 

Specifications:

Maximum overrun range: 300PPN
Signal output: 0.1 0.02mA
Response time (T90) < 15s
Load resistance 100 Ω

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement