| Payment Terms | L/C, D/A, D/P, T/T, , |
| Supply Ability | 5000PCS |
| Delivery Time | 5-8 work days |
| Packaging Details | Standard packaging |
| Detection Range | 5 - 500 ppm NH₃ |
| Standard Circuit Conditions | ≤ 24 V DC |
| Heater Voltage (Vh) | 5.0 V ± 0.1 V AC or DC |
| Heater Resistance (Rh) | 29 Ω ± 3 Ω |
| Heater Consumption (Ph) | ≤ 900 mW |
| Operating Temperature | - 10℃ - 45℃ |
| Model Number | MQ137 MQ-137 |
| Place of Origin | CN |
View Detail Information
Explore similar products
Storm Pro 2 Portable Lightning Storm Detector Storm Detection and Early Warning
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Ammonia Gas Sensors A-Series Four-Electrode Electrochemical
H2S-B4 Hydrogen Sulfide Sensor High Resolution 4-electrode H2S No Condensation
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, , | Supply Ability | 5000PCS |
| Delivery Time | 5-8 work days | Packaging Details | Standard packaging |
| Detection Range | 5 - 500 ppm NH₃ | Standard Circuit Conditions | ≤ 24 V DC |
| Heater Voltage (Vh) | 5.0 V ± 0.1 V AC or DC | Heater Resistance (Rh) | 29 Ω ± 3 Ω |
| Heater Consumption (Ph) | ≤ 900 mW | Operating Temperature | - 10℃ - 45℃ |
| Model Number | MQ137 MQ-137 | Place of Origin | CN |
| High Light | MQ137 semiconductor gas sensor ,NH₃ gas alarm sensor ,domestic gas sensor with warranty | ||
MQ137 Semiconductor Gas Sensor For Domestic NH₃ Gas Alarms
Working Principle:
The sensitive material SnO₂ of the MQ137 gas sensor has lower conductivity in clean air. When ammonia gas is present, the sensor's conductivity increases with the rise of gas concentration. Users can convert the change of conductivity into a corresponding output signal of gas concentration through a simple circuit.
Applications:
|
Parameter |
Symbol |
Value |
Unit |
Remarks |
|---|---|---|---|---|
| Detection Range | - | 5 - 500 | ppm | For NH₃ |
| Standard Circuit Conditions (Loop Voltage) | Vc | ≤ 24 | V DC | - |
| Heater Voltage | Vh | 5.0 V ± 0.1 V | - | AC or DC |
| Load Resistance | Rl | Adjustable | - | - |
| Heater Resistance | Rh | 29 Ω ± 3 Ω | - | At room temperature |
| Heater Consumption | Ph | ≤ 900 | mW | - |
| Sensitivity | S | Rs (in air)/Rs (50 ppm NH₃) ≥ 2 | - | - |
| Output Voltage | △Vs | ≥ 0.5 | V | In 50 ppm NH₃ |
| Concentration Slope | α | ≤ 0.6 | - | R₂₀₀ ppm/R₅₀ ppm NH₃ |
| Standard Test Temperature | - | 20℃ ± 2℃ | - | - |
| Standard Test Humidity | - | 55% ± 5% | RH | - |
| Pre-heat Time | - | Over 48 | hours | - |
| Operating Temperature | - | -10 - 45 | ℃ | - |
| Storage Temperature | - | -20 - 70 | ℃ | - |
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Shenzhen Yijiajie Electronic Technology Co., Ltd. has long been deeply engaged in the field of sensing and control technology, specializing in sensor solutions and technical support. The company is an authorized distributor for City, and Siargo, and maintains long-term, stable partnerships with othe... Shenzhen Yijiajie Electronic Technology Co., Ltd. has long been deeply engaged in the field of sensing and control technology, specializing in sensor solutions and technical support. The company is an authorized distributor for City, and Siargo, and maintains long-term, stable partnerships with othe...
Get in touch with us
Leave a Message, we will call you back quickly!