China YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor
China YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor

  1. China YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor
  2. China YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor
  3. China YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor

YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 2200
Delivery Time 5-8 days
Packaging Details Box pack
Heater Resistance 95 Ω ± 10 Ω (at room temperature)
Heater Power Consumption ≤ 300 mW
Sensitivity ≥ 5 (at 50 ppm NH₃)
Concentration Slope ≤ 0.6
Sensitive Element Resistance (Rs) 1 kΩ – 30 kΩ (at 50 ppm NH₃)
Warm-up Time ≥ 48 h
Brand Name YJJ
Model Number MP702
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 2200
Delivery Time 5-8 days Packaging Details Box pack
Heater Resistance 95 Ω ± 10 Ω (at room temperature) Heater Power Consumption ≤ 300 mW
Sensitivity ≥ 5 (at 50 ppm NH₃) Concentration Slope ≤ 0.6
Sensitive Element Resistance (Rs) 1 kΩ – 30 kΩ (at 50 ppm NH₃) Warm-up Time ≥ 48 h
Brand Name YJJ Model Number MP702
Place of Origin CHINA
High Light YJJ MP702 ammonia gas sensorplanar semiconductor NH3 sensor0-100PPM gas sensor with warranty

Product Description:

YJJ MP702 0-100PPM Planar Semiconductor Ammonia (NH3) Gas Sensor

 

Features:

MP-702 planar semiconductor ammonia (NH3) gas sensor, with metal packaging, is suitable for detecting ammonia concentrations ranging from 0 to 100 ppm. Its typical applications include ammonia leakage monitoring in refrigerators and cold storages, as well as risk control in aquaculture.

Parameters Sign / Unit Value / Condition Remarks

Detected gas — Air ammonia (NH3) —

Detection range ppm 0 - 100 ppm —

Loop voltage VC ≤ 24 V DC —

Heating voltage VH 5.0 V ± 0.1 V AC/DC —

Load resistance RL Adjustable —

Heating resistance RH 95 Ω ± 10 Ω (at room temperature) —

Heating power consumption PH ≤ 300 mW —

Sensitivity S ≥ 5 (at 50 ppm NH3) S = Rs (air) / Rs (50 ppm NH3)

Concentration slope α ≤ 0.6 α = R100 ppm / R30 ppm NH3

Sensitive body resistance Rs 1 kΩ - 30 kΩ (at 50 ppm NH3) —

Standard test conditions — 20 ℃ ± 2 ℃; 65% ± 5% RH; VC = 5.0 V ± 0.1 V; VH = 5.0 V ± 0.1 V —

Preheating time — ≥ 48 h —

Form / Packaging — Metal packaging, 4 pins 1, 2 pins for heating; 3, 4 pins for measurement

Typical characteristics and usage tips

Working principle: Metal oxide semiconductor gas-sensitive layer, conductivity increases with NH3 concentration, and Rs changes are converted into voltage output through RL.

Response and recovery: Highly sensitive to ammonia, response/recovery is fast, suitable for real-time monitoring.

Environmental impact: Sensitivity is affected by temperature and humidity. Standard test conditions are 20 ℃ / 65% RH; calibration and use should be performed under similar temperature and humidity.

Installation and soldering: Prefer manual soldering; 250 ℃ ≤ 3 s; use the least chlorine-containing rosin flux; avoid volatile silicon substances, corrosive gases, and strong shock and vibration.

Circuit connection and selection tips

Dual voltage supply: VC is the measurement circuit voltage (≤ 24 V DC), VH is the heating voltage (5.0 V AC/DC); connect 1, 2 pins for heating, 3, 4 pins for measurement, they can share the power supply, pay attention to polarity.

RL selection: Convert Rs changes into VRL through RL; RL can be optimized according to the target output range and noise requirements (commonly in the kΩ range).

Long-term storage and aging: Unpowered long-term storage will drift, before use, it is necessary to fully age (1 - 6 months ≥ 72 h; > 6 months ≥ 168 h).

 

Specifications:

 

Parameter Symbol/Unit Value/Condition
Detected Gas Ammonia (NH₃)
Detection Range ppm 0 – 100 ppm
Circuit Voltage Vc ≤ 24 V DC
Heater Voltage Vh 5.0 V ± 0.1 V AC/DC
Load Resistance Rₗ Adjustable

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement