{"title":"7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutic","imgUrl":"https:\/\/img.chinax.com\/nimg\/fa\/f5\/6866b5096f1f52257d676781caf8-200x200-1\/7eto_100_ethylene_oxide_gas_sensor_for_medical_device_sterilization_pharmaceutic.jpg","attrs":{"Model Number":"7ETO-100","Place of Origin":"CN","Minimum Order Quantity":"1PCS","Price":"Negotiable"}}
{"title":"H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/de\/2c3edff3ffc6e6ffe104cf9106a5-200x200-1\/h2s_ah_high_current_hydrogen_sulfide_sensor_for_portable_devices_0_03_ppm_resolution_2_year_service_life.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-AH","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In","imgUrl":"https:\/\/img.chinax.com\/nimg\/3b\/76\/709cbd27e1256f889d1932c83ee4-200x200-1\/nh3_b1_four_electrode_electrochemical_ammonia_sensor_28nh3_sensor_29_is_used_in_ammonia_gas_transmitter.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NH3-B1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor","imgUrl":"https:\/\/img.chinax.com\/nimg\/93\/a5\/26fe289e29911b4d52b464ddf558-200x200-1\/h2s_b4_high_resolution_hydrogen_sulfide_sensor_28h2s_sensor_29_is_used_to_monitor_trace_hydrogen_sulfide_in_air_quality.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-B4","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide","imgUrl":"https:\/\/img.chinax.com\/nimg\/8e\/e9\/481f097eb9ce0c098d1848168c96-200x200-1\/no2_a1_nitrogen_dioxide_sensor_28portable_no2_sensor_29_for_nitrogen_dioxide_portable_monitor.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NO2-A1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection","imgUrl":"https:\/\/img.chinax.com\/nimg\/ad\/40\/82c7966c902dc6957c764eec744c-200x200-1\/no_a1_nitric_oxide_gas_sensor_no_sensor_used_for_automobile_exhaust_detection.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
7ETO-100 Ethylene Oxide Gas Sensor For Medical Device Sterilization Pharmaceutical Manufacturing
The 7ETO-100 operates on the electrochemical detection principle, leveraging a three-electrode cell immersed in an electrolyte solution:
Gas Diffusion: Ethylene oxide gas in the environment diffuses through a porous membrane (gas-permeable membrane) into the sensor’s internal electrolyte.
Electrochemical Reaction: At the working electrode (cathode), ETO undergoes oxidation, producing electrons, protons (H⁺), and harmless byproducts (e.g., CO₂, H₂O).
Current Generation: The electrons generated by the oxidation reaction flow through an external circuit to the counter electrode (anode), creating a measurable electrical current. The magnitude of this current is linearly proportional to the concentration of ETO in the sample gas (per Faraday’s Law of Electrolysis).
Stability Maintenance: The reference electrode provides a stable voltage reference, preventing drift in the working electrode’s potential and ensuring long-term measurement accuracy.
4. Typical Applications
The 7ETO-100 is engineered for scenarios requiring ETO monitoring, with core use cases including:
4.1 Medical Sterilization Industry
Ethylene oxide is widely used to sterilize heat-sensitive medical devices (e.g., surgical instruments, syringes, implants). The 7ETO-100 is integrated into:
Sterilization Chamber Monitors: Real-time tracking of ETO concentration during the sterilization cycle to ensure effective microbial inactivation.
Post-Sterilization Ventilation Systems: Detection of residual ETO in sterilized equipment or exhaust air, ensuring levels meet safety standards (e.g., ≤ 1 ppm for personnel exposure) before devices are used or air is released.
4.2 Chemical & Pharmaceutical Manufacturing
In facilities producing ETO or using ETO as a raw material (e.g., for ethylene glycol synthesis, detergent production):
Fixed-Point Leak Detectors: Installation near pipelines, valves, or reaction vessels to trigger alarms if ETO leaks occur (preventing toxic exposure or fire risks).
Process Control Systems: Monitoring ETO concentration in reaction streams to optimize production efficiency and ensure product quality.
4.3 Environmental & Occupational Safety
Portable Gas Detectors: Used by maintenance workers, laboratory staff, or emergency responders to monitor personal exposure to ETO in confined spaces (e.g., sterilization rooms, chemical storage areas) or during leak investigations.
Indoor Air Quality (IAQ) Monitors: In facilities where ETO may accumulate (e.g., hospitals, pharmaceutical plants), the sensor ensures indoor ETO levels comply with occupational health regulations (e.g., OSHA’s permissible exposure limit (PEL) for ETO: 1 ppm over an 8-hour workday).
4.4 Food Processing (Optional)
In some food sterilization applications (e.g., low-temperature sterilization of packaged foods), the 7ETO-100 monitors residual ETO to ensure food safety and compliance with global food standards.
5. Installation & Operation Guidelines
5.1 Installation Notes
Location: Mount the sensor in areas where ETO is likely to accumulate (e.g., near sterilization chambers, ETO storage tanks) or where personnel frequent. Avoid direct sunlight, extreme temperatures, or high-humidity (condensing) environments.
Gas Inlet: For diffusion-type sensors, ensure unobstructed air flow around the sensor (minimum 5 cm clearance from walls/obstacles). For pump-type sensors, connect the gas inlet tube to the sampling point (tube length ≤ 2 meters to avoid response delay).
Wiring: Follow the sensor’s pinout diagram (provided in the datasheet) for power and signal connections. Use shielded cables for analog signals to reduce electromagnetic interference (EMI).
5.2 Calibration
Initial Calibration: Perform a two-point calibration (zero calibration with clean air, span calibration with a known ETO concentration gas) before first use.
Routine Calibration: Recalibrate every 3–6 months (or as required by local regulations) to maintain accuracy. Calibration gas should be certified (NIST-traceable or equivalent) with a concentration close to the sensor’s full scale (e.g., 80 ppm for a 0–100 ppm sensor).
5.3 Maintenance
Cleaning: Periodically wipe the sensor’s exterior with a dry, lint-free cloth. Do not use solvents or water on the gas inlet membrane.
Replacement: Replace the sensor if: (1) response time exceeds 60 seconds, (2) accuracy deviates by >10% of FS after calibration, or (3) the sensor reaches its rated lifespan.
6. Safety Precautions
Toxic Gas Risk: Ethylene oxide is toxic and carcinogenic—always wear appropriate PPE (e.g., gas mask, gloves) when handling ETO or performing sensor maintenance in potentially contaminated areas.
Flammability: ETO is flammable (explosion limit: 3%–100% by volume in air)—avoid installing the sensor near open flames, sparks, or high-temperature surfaces.
Sensor Handling: Do not disassemble the sensor (risk of electrolyte leakage, which may cause skin irritation). Dispose of old sensors in accordance with local hazardous waste regulations.
Parameter Category
Parameter Name
Specification
Unit
Remarks
Target Gas & Sensing Principle
Target Gas
Ethylene Oxide (EO/ETO)
-
Specialized for EO detection; not compatible with other toxic gases
Under continuous operation in clean air (EO concentration < 1 ppm); lifespan shortens in high-concentration EO
Calibration Interval
3 ~ 6
Months
Recommended for maintaining accuracy; use NIST-traceable EO calibration gas
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...