| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability | 2200 |
| Delivery Time | 5-8 days |
| Packaging Details | Canned |
| Detection gas | NO |
| Range | 0-2000 ppm |
| Resolution | 1 ppm |
| Sensitivity | 0.10 ± 0.02 μA/ppm |
| Response time T90 | ≤ 25 seconds |
| Baseline signal | 0 - +12 ppm |
| Baseline drift | < 30 ppm |
| Linearity | 0 - 2000 ppm |
| Brand Name | YJJ |
| Model Number | 3NO-2000CT 058-3000-100 |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Gas Sensor 3 Electrode High Precision And Sensitivity
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 2200 |
| Delivery Time | 5-8 days | Packaging Details | Canned |
| Detection gas | NO | Range | 0-2000 ppm |
| Resolution | 1 ppm | Sensitivity | 0.10 ± 0.02 μA/ppm |
| Response time T90 | ≤ 25 seconds | Baseline signal | 0 - +12 ppm |
| Baseline drift | < 30 ppm | Linearity | 0 - 2000 ppm |
| Brand Name | YJJ | Model Number | 3NO-2000CT 058-3000-100 |
| Place of Origin | CHINA | ||
| High Light | Electrochemical NO sensor for flue gas ,Nitric oxide sensor emission monitoring ,YJJ 3NO-2000CT gas sensor | ||
Product Description:
YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring
Features:
3NO-2000CT is a three-electrode electrochemical nitric oxide (NO) sensor, primarily used for quantitative detection of NO concentrations ranging from 0 to 2000 ppm. It is suitable for harsh industrial emission and environmental monitoring conditions and can directly replace the mainstream 3-series NO sensors. It features linear output, fast response, and good long-term stability.
Core parameter description (20℃, standard atmospheric pressure)
Parameter Value Remarks
Detected gas Nitric oxide (NO) Three-electrode electrochemical principle
Range 0-2000 ppm Maximum overload 5000 ppm
Sensitivity 0.10 ± 0.02 μA/ppm (typical value 0.10 μA/ppm) Current signal is proportional to the concentration, and the signal is a positive output
Response time (T90) ≤ 25s Quickly captures concentration changes
Baseline (20℃) 0 - +12 ppm Initial zero deviation is small
Baseline drift (-20℃ to 50℃) < 30 ppm Controllable drift in a wide temperature range
Resolution 1 ppm Meet the routine monitoring accuracy
Linearity Linear With bias + 300 mV, a corresponding bias circuit is required
Operating temperature -20℃ to 50℃ Adapt to industrial and outdoor environments
Pressure range 1 standard atmosphere ± 10% Compatible with routine conditions
Humidity range 15% - 90% RH (no condensation) Prevent the influence of condensation on performance
Long-term stability < 2% signal value / month Reliable long-term monitoring data
Service life 3 years (in air) Storage temperature 10℃ to 30℃
Safety integrity Maximum open-circuit voltage 1.3V, maximum short-circuit current < 1mA Compatible with explosion-proof scenarios
Main application
Industrial flue gas emission monitoring: Used for real-time monitoring of NO emissions from fixed pollution sources such as coal-fired power plants, waste incineration plants, and nitric acid plants, meeting the continuous monitoring requirements of environmental protection regulations for chimney emissions, and can work stably in high-concentration and high-dust harsh conditions.
Environmental air quality detection: Integrated into air quality monitoring stations or mobile monitoring equipment, used for grid-based monitoring of NO concentrations in urban and industrial parks, assisting in pollution source tracing and governance decisions, providing data support for environmental quality assessment.
Industrial safety and process control: In production processes involving NO such as chemical synthesis, metal processing, and welding, real-time monitoring of leakage and process gas concentrations, ensuring personnel safety and production stability, and avoiding health hazards and safety accidents caused by NO leakage.
Equipment and instrument matching: As the core sensing element, embedded in portable NO detectors, online analysis instruments, etc., compatible with explosion-proof, outdoor, etc. complex conditions, supporting rapid replacement of mainstream 3-series sensors, reducing maintenance costs.
Specifications:
| Overload | 0-2000 PPM |
| Response time | 25 s |
| Size | 20 x 16.5 |
| Sulfur dioxide detection range | 0-50ppm |
| Sensitivity | 450-750 na/PPM |
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!