China factories

Chat Now Send Email
China factory - ShenzhenYijiajie Electronic Co., Ltd.

ShenzhenYijiajie Electronic Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +

  1. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
  2. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
  3. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
  4. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
  5. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +
  6. China YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +

YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor +

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 2200
Zero Point Drift < 0.5% FS / Year
Cross-Interference NO2 SO₂, NO
Operating Environment -20 to +50°C; 15 - 90% RH, no condensation
Signal Output RS485 /4-20mA analog
Payment Terms L/C, D/A, D/P, T/T, Western Union
Lifespan 24 months
Packaging Details Box pack
Power Supply DC 9-24V
Delivery Time 5-8 days
Resolution 0.02 ppm
Sensitivity -600 ~ -1150 nA/ppm
Model Number CL2-B1
Place of Origin Britain
Brand Name YJJ

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 2200 Zero Point Drift < 0.5% FS / Year
Cross-Interference NO2 SO₂, NO Operating Environment -20 to +50°C; 15 - 90% RH, no condensation
Signal Output RS485 /4-20mA analog Payment Terms L/C, D/A, D/P, T/T, Western Union
Lifespan 24 months Packaging Details Box pack
Power Supply DC 9-24V Delivery Time 5-8 days
Resolution 0.02 ppm Sensitivity -600 ~ -1150 nA/ppm
Model Number CL2-B1 Place of Origin Britain
Brand Name YJJ
High Light chlorine gas electrochemical sensordigital signal conditioning moduleYJJ CL2-B1 gas sensor

Product Description:

YJJ CL2-B1 Chlorine Gas Secondary Development Module Electrochemical Sensor + Signal Conditioning Digital Module

 

Features:

CL2-B1 Chlorine Gas Secondary Development Module (CL2-B1 Electrochemical Sensor + Signal Conditioning Digital Module)

 

> Note: CL2-B1 is the original electrochemical bare sensor; **Secondary development module = CL2-B1 sensor + Special Electrochemical Bias Conditioning Circuit + MCU Signal Processing Board**, completing I-V conversion, zero point, temperature compensation, and outputting digital/analog signals externally, directly connecting to PLC, microcontrollers, industrial control systems, without needing to perform weak current conditioning by oneself

 

I. Sensor Body Underlying Parameters (Module Built-in CL2-B1)

| Measured Gas | Cl₂ Chlorine Gas |

| Measurement Principle | Three-electrode electrochemical fuel cell |

| Measurement Range | **0 - 20 ppm** |

| Short-term Overload | 60 ppm (not for long-term use) |

| Sensitivity | -600 ~ -1150 nA/ppm |

| T90 Response Time | < 60s |

| Resolution | 0.02 ppm |

| Zero Point Drift | < 0.5% FS / Year |

| Lifespan | 24 months |

| Working Environment | -20 to +50°C; 15 - 90% RH, no condensation |

| Cross-Interference | NO₂ significant positive interference; SO₂, NO weak interference |

 

II. Complete Electrical Parameters of the Secondary Development Module (Common Digital Module Specifications Available on the Market)

 

Table

| Power Supply | **DC 9-24V wide voltage range**; typical power consumption < 120mA |

| Signal Output (either one or dual output) | ①RS485 - Modbus - RTU (digital); ②4-20mA analog |

| 4-20mA Mapping | 4mA = 0ppm; 20mA=20ppm |

| RS485 default | 9600‑8‑N‑1; Address 1; Address and baud rate can be modified |

| Module output data | Chlorine gas concentration (ppm), sensor temperature, device status, fault bit |

| Accuracy (whole machine) | ±3% FS (including sensor + circuit error) |

| Update rate | 1Hz; Configurable |

| Protection | Circuit board IP30; Sensor chamber IP40 |

| Size | Approximately 85×55×35mm (varies slightly by different manufacturers) |

 

III. Key registers of Modbus‑RTU (Key focus for secondary development)

 

| Register address | Function | Data type | Description |

| 0x0000 | Chlorine gas concentration | uint16 | Original value, multiplied by 10; Example: 125 → 12.5 ppm |

| 0x0001 | Module internal temperature | int16 | Multiplied by 10 |

| 0x0002 | Device status | uint16 | 0 - Normal; 1 - Sensor fault; 2 - Zero point abnormal |

| 0x0100 | Device address | uint16 | 1 - 247 (writeable) |

| 0x0101 | Baud rate setting | uint16 | 0 = 9600, 1 = 19200… |

 

Reading example: Register 0x0000 returns `00C8`, decimal 200 → 20.0 ppm (full scale).

 

IV. Pin Definitions (Standard 5-pin Terminal)

| 1 | VCC+ 9‑24VDC |

| 2 | GND Power Ground |

| 3 | 485‑A |

| 4 | 485‑B |

| 5 | 4-20mA Output |

 

Key Considerations for Secondary Development

1. Polarization Time**: The module must be polarized for 2-4 hours before power-on for the electrochemical sensor to stabilize; new sensors must be fully polarized before being calibrated with Alphasense.

2. Condensation Hazard**: Chlorine module must not have condensation; condensation will directly corrode the electrochemical electrolyte and permanently damage the sensor; in high-humidity scenarios, additional air path drying and filtering are required.

3. Interference Gases**: Reading is falsely high when there is NO₂ (nitrogen dioxide) in the environment; the software needs to perform cross-compensation.

4. Zero Point Calibration**: Zero point calibration must be completed by introducing clean zero air; it is not allowed to forcibly zero in normal indoor air.

5. IST Version Differentiation**: CL2-B1-IST (with onboard storage + temperature chip) module can read the original factory sensitivity parameters, simplifying calibration; ordinary CL2-B1 does not have an IST chip and requires manual writing of sensitivity.

6. Wiring**: RS485 communication is recommended to use shielded twisted pair; the 4-20mA load resistance should be ≤ 500Ω.

 

Applications

Chlorine leakage in sewage treatment plants, chemical workshops, scrubber tail gas, pipeline chlorine monitoring, PLC/DCS system integration.

 

If you need, I can provide:

1. Complete Modbus read-write instructions for the module;

2. 4-20mA conversion formula;

3. Comparison table of CL2-B1 bare sensor vs CL2-B1 secondary development module.

 

Specifications:

Measured Gas CL2
Measurement Range‌ 0 - 20 ppm
Short-term Overload 60 ppm
Sensitivity ‌ -600 ~ -1150 nA/ppm
T90 Response Time < 60s

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement