China factories

Chat Now Send Email
China factory - ShenzhenYijiajie Electronic Co., Ltd.

ShenzhenYijiajie Electronic Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for

  1. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
  2. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
  3. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
  4. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
  5. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for
  6. China INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for

INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for

  1. MOQ: 1PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, ,
Detection Gas Methane (CH4)
Delivery Time 5-8 work days
Average Operating Current 32 mA (Typical)
Supply Ability 5000PCS
Operating Temperature Range -40°C ~ +75°C
Working Humidity Range 0% ~ 95% RH (non-condensing)
Packaging Details Paper box
High Resolution Up to 10 ppm
Measuring Range 0 ~ 100% VOL
Place of Origin USA
Model Number INIR2-ME5

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, , Detection Gas Methane (CH4)
Delivery Time 5-8 work days Average Operating Current 32 mA (Typical)
Supply Ability 5000PCS Operating Temperature Range -40°C ~ +75°C
Working Humidity Range 0% ~ 95% RH (non-condensing) Packaging Details Paper box
High Resolution Up to 10 ppm Measuring Range 0 ~ 100% VOL
Place of Origin USA Model Number INIR2-ME5
High Light NDIR methane gas sensor ,methane gas sensor for petroleum ,natural gas industry methane sensor

 

             INIR2-ME5 Integrated NDIR (Non-Dispersive Infrared) Methane Gas Sensor for Petroleum & Natural Gas Industry

 

 

 

Product Features:

  • Maintenance-Free NDIR Optical Principle: Adopts non-dispersive infrared detection technology, no catalytic bead failure or gas poisoning risk, free from oxygen dependence, realizing long-term maintenance-free continuous monitoring.
  • High Precision & Ultra-High Resolution: Supports trace methane detection with resolution up to 10 ppm, equipped with professional full-range temperature compensation algorithm, effectively eliminating ambient temperature drift and ensuring stable and accurate data output.
  • Automatic Dual-Range Switching: Built-in intelligent range identification program, automatically switches high/low detection ranges according to gas concentration, taking into account low-concentration trace monitoring and high-concentration full-scale detection.
  • Complete Fault Self-Diagnosis Function: Real-time monitoring of active signal, reference signal and internal operating status, with built-in CRC verification and error generation mechanism, realizing comprehensive fault diagnosis and improving system safety and reliability.
  • Diversified Standard Outputs: Supports analog voltage output and UART serial digital communication, compatible with mainstream industrial acquisition systems and host equipment, convenient for data uploading and secondary development integration.
  • Industrial Explosion-Proof Grade: Complies with ATEX and IECEx international explosion-proof standards (Ex db IIC Gb), suitable for high-risk flammable and explosive industrial hazardous areas.
  • Excellent Environmental Adaptability: Ultra-wide working temperature range of -40°C ~ +75°C, stable performance in high and low temperature, humid and complex industrial environments, strong anti-interference ability.
  • Long Service Life & High Stability: No chemical consumption during operation, with ultra-low long-term drift and attenuation, rated service life far exceeding traditional catalytic sensors, greatly reducing equipment replacement and maintenance costs.

Product Applications:

The INIR2-ME5 high-precision infrared methane sensor is specially used for real-time detection and leakage early warning of flammable methane gas, widely applied in industrial safety, energy mining and environmental protection fields:
  • Petroleum & Natural Gas Industry: Methane leakage monitoring for natural gas stations, oil and gas transmission pipelines, petrochemical plants and gas storage facilities to prevent flammable gas explosion risks.
  • Coal & Mining Industry: Underground mine gas concentration real-time monitoring, roadway gas safety early warning and mining operation environmental safety detection.
  • Industrial Safety Monitoring: Flammable gas detection in chemical workshops, gas plants and industrial confined spaces, supporting safety production monitoring and risk assessment.
  • Environmental Gas Monitoring: Atmospheric methane concentration detection, greenhouse gas monitoring and industrial volatile organic gas environmental compliance testing.
  • Smart Gas Safety Equipment: Matching with fixed industrial gas alarms, portable methane detectors and intelligent safety monitoring terminals for long-term unattended online monitoring.
  • New Energy & Biogas Engineering: Biogas station gas concentration monitoring, methane energy equipment operation detection and new energy gas utilization safety supervision.

 

Product Model INIR2-ME5
Detection Principle NDIR Non-Dispersive Infrared Spectroscopy
Detection Gas Methane (CH4)
Measuring Range 0 ~ 100% VOL
High Resolution Up to 10 ppm
Detection Accuracy ±6% reading or ±0.06% FS (whichever is greater)
Working Voltage 3.2 V ~ 5.25 V DC (Typical 3.3 V DC)
Average Operating Current 32 mA (Typical)
Output Signal Analog Voltage + UART Serial Digital Output
Operating Temperature Range -40°C ~ +75°C
Working Humidity Range
 
0% ~ 95% RH (non-condensing)
Explosion-Proof Certification ATEX II 2G Ex db IIC Gb, IECEx Ex db IIC Gb
Self-Diagnosis Function Full fault diagnosis, signal monitoring and CRC error verification
Temperature Compensation Built-in high-precision temperature sensor & algorithm compensation
Range Switching Automatic dual-range intelligent switchover
Oxygen Dependence Zero oxygen dependence
Anti-Poisoning Performance No poisoning risk, long-term stable operation
Service Life ≥ 5 years (standard industrial conditions)

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Shenzhen Yijiajie Electronic Technology Co., Ltd. has long been deeply engaged in the field of sensing and control technology, specializing in sensor solutions and technical support. The company is an authorized distributor for City, and Siargo, and maintains long-term, stable partnerships with othe... Shenzhen Yijiajie Electronic Technology Co., Ltd. has long been deeply engaged in the field of sensing and control technology, specializing in sensor solutions and technical support. The company is an authorized distributor for City, and Siargo, and maintains long-term, stable partnerships with othe...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement