| Response time T90 | < 25 s |
| Packaging Details | Palletized |
| Sensitivity | 50 - 90 nA/ppm |
| Supply Ability | 1500 |
| Linear error (0 - 1000 ppm) | < ±30 ppm |
| Overload range | Up to 5000 ppm |
| Payment Terms | L/C, D/A, D/P, T/T, , |
| Zero point current | < 2.5 ppm (equivalent concentration) |
| Resolution | < 0.5 ppm |
| Delivery Time | 5-8 days |
| Operating temperature | -30°C ~ +55°C |
| Measurement range | 0 - 2000 ppm |
| Model Number | H2O2-B1 |
| Brand Name | YJJ |
| Place of Origin | Britain |
View Detail Information
Explore similar products
Storm Pro 2 Portable Lightning Storm Detector Storm Detection and Early Warning
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Ammonia Gas Sensors A-Series Four-Electrode Electrochemical
H2S-B4 Hydrogen Sulfide Sensor High Resolution 4-electrode H2S No Condensation
Product Specification
| Response time T90 | < 25 s | Packaging Details | Palletized |
| Sensitivity | 50 - 90 nA/ppm | Supply Ability | 1500 |
| Linear error (0 - 1000 ppm) | < ±30 ppm | Overload range | Up to 5000 ppm |
| Payment Terms | L/C, D/A, D/P, T/T, , | Zero point current | < 2.5 ppm (equivalent concentration) |
| Resolution | < 0.5 ppm | Delivery Time | 5-8 days |
| Operating temperature | -30°C ~ +55°C | Measurement range | 0 - 2000 ppm |
| Model Number | H2O2-B1 | Brand Name | YJJ |
| Place of Origin | Britain | ||
| High Light | H2O2 gas sensor 0-2000ppm ,electrochemical H2O2 sensor medical ,pharmaceutical H2O2 sensor with warranty | ||
Product Description:
YJJ H2O2-B1 Electrochemical H2O2 Gas Sensor 0-2000ppm Medical Pharmaceutical Fields
Features:
I. Basic Information
Type: Three-electrode electrochemical gas sensor
Detected gas: Hydrogen peroxide (H2O2, hydrogen peroxide vapor)
Packaging: B-series standard round probe, direct insertion with three-pin contacts
II. Core Electrical Parameters (25℃) Table
Project Technical Parameters
Measurement Range 0 - 2000 ppm
Overload Range Up to 5000 ppm for short-term tolerance
Sensitivity 50 - 90 nA/ppm (calibrated with CO standard gas)
Response Time T90 < 25 s
Resolution < 0.5 ppm
Zero Current < 2.5 ppm (equivalent concentration)
Linear Error (0 - 1000 ppm) < ±30 ppm
Operating Temperature -30℃ ~ +55℃
Humidity Conditions 15 - 90% RH (no condensation water vapor)
Air Pressure Range 80 - 120 kPa
Expected Lifespan ≥ 24 months, original factory warranty for 2 years
Recommended Load Resistance 47 - 100 Ω
III. Product Features
Designed specifically for high-concentration hydrogen peroxide steam, suitable for high-concentration conditions in sterilization chambers;
Resistant to water vapor interference, with minimal baseline drift in low-temperature humidified sterilization environments;
Three-electrode structure, suppressing cross-interference of oxidants, stable measurement;
Extremely low long-term zero drift, suitable for continuous online 24-hour uninterrupted monitoring;
B series universal packaging, can directly connect to existing gas detection mainboards.
IV. Main Applications
1. Medical and Pharmaceutical (Core Application)
Concentration monitoring of hydrogen peroxide in low-temperature plasma sterilization cabinets;
Concentration detection of hydrogen peroxide vaporization in pharmaceutical clean areas and isolation cabins for VHP sterilization;
Closed-loop control of sterilization chamber concentration, exhaust gas residual detection;
Disinfection gas monitoring in biosafety laboratories.
2. Food Packaging Industry
Gas detection in epoxy ethane + hydrogen peroxide composite sterilization lines for food packaging bags;
Real-time monitoring and over-limit alarm of H2O2 concentration in packaging workshop fumigation disinfection.
3. Chemical Environmental Working Conditions
Hydrogen peroxide production workshops, storage tank leakage steam detection;
Tail gas monitoring in advanced oxidation processes of wastewater treatment;
Hydrogen peroxide emission monitoring in chemical oxidation sections.
4. Instrument Accessories
Fixed online H2O2 detector, built-in gas monitoring module for sterilization equipment, portable disinfection gas detector.
V. Identifying Similar Models
H2O2-A1: Low range version (0 - 100 ppm);
H2O2-B1: High range model (0 - 2000 ppm), used for high-concentration sterilization scenarios, the two cannot be directly interchanged.
Specifications:
| Response time T90 | 25 seconds |
| Resolution | < 0.5 ppm |
| Zero point current | < 2.5 ppm (equivalent concentration) |
| Linear error (0 - 1000 ppm) | < ±30 ppm |
| Operating temperature | -30°C to +55°C |
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!