Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"ETO-A1 Three-electrode Electrochemical Ethylene Oxide (ETO\/C2H4O) Gas Sensor for","imgUrl":"https:\/\/img.chinax.com\/nimg\/11\/09\/c9096d32e2bb38ff94a3f442579e-200x200-1\/eto_a1_three_electrode_electrochemical_ethylene_oxide_28eto_2fc2h4o_29_gas_sensor_for.jpg","attrs":{"Delivery Time":"5-8 work days","Response Time (T90)":"\u2264 150 s (0 to 20ppm ETO)","Model Number":"ETO-A1","Detection Range":"0 ~ 100 ppm"}}
{"title":"Storm Pro 2 Portable Lightning Storm Detector Storm Detection and Early Warning","imgUrl":"https:\/\/img.chinax.com\/nimg\/44\/ea\/bd4a55c9c86525682ef046ff62e2-200x200-1\/storm_pro_2_portable_lightning_storm_detector_storm_detection_and_early_warning_equipment.jpg","attrs":{"Model Number":"Storm Pro 2","Price":"Negotiable","Packaging Details":"Standard Package","Supply Ability":"10000pcs\/Month"}}
{"title":"H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/de\/2c3edff3ffc6e6ffe104cf9106a5-200x200-1\/h2s_ah_high_current_hydrogen_sulfide_sensor_for_portable_devices_0_03_ppm_resolution_2_year_service_life.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-AH","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NH3-B1 Ammonia Gas Sensors A-Series Four-Electrode Electrochemical","imgUrl":"https:\/\/img.chinax.com\/nimg\/3b\/76\/709cbd27e1256f889d1932c83ee4-200x200-1\/nh3_b1_ammonia_gas_sensors_a_series_four_electrode_electrochemical.jpg","attrs":{"Pressure range":"Kpa 80~120","Bias":"mV 200","Weight":"g & LT; 13","Humidity range":"% RH 15 to 90"}}
{"title":"H2S-B4 Hydrogen Sulfide Sensor High Resolution 4-electrode H2S No Condensation","imgUrl":"https:\/\/img.chinax.com\/nimg\/93\/a5\/26fe289e29911b4d52b464ddf558-200x200-1\/h2s_b4_hydrogen_sulfide_sensor_high_resolution_4_electrode_h2s_no_condensation.jpg","attrs":{"Temperature range":"-30 \u2103 to 50 \u2103","Storage life":"3-20\u2103 sealed storage life (months) 6","Weight":"g & LT; 13","Load resistance":"\u03c9 to 100"}}
{"title":"NO2-A1 Nitrogen Dioxide Gas Sensor 3 Electrode High Precision And Sensitivity","imgUrl":"https:\/\/img.chinax.com\/nimg\/8e\/e9\/481f097eb9ce0c098d1848168c96-200x200-1\/no2_a1_nitrogen_dioxide_gas_sensor_3_electrode_high_precision_and_sensitivity.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO2-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
{"title":"NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection","imgUrl":"https:\/\/img.chinax.com\/nimg\/ad\/40\/82c7966c902dc6957c764eec744c-200x200-1\/no_a1_nitric_oxide_gas_sensor_no_sensor_used_for_automobile_exhaust_detection.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
ETO-A1 Three-electrode Electrochemical Ethylene Oxide (ETO/C2H4O) Gas Sensor for Gas Detection Equipment Manufacturing
Product Features:
Ultra-High Detection Precision: Ultra-low noise design with resolution less than 0.1 ppm equivalent, capable of capturing trace ETO concentration changes, fully meeting the detection requirements of occupational exposure limit (0.1 ppm STEL).
Stable & Reliable Performance: Adopts premium gold-plated electrode and PTFE waterproof and anti-poisoning membrane structure, effectively resisting environmental interference and gas poisoning, with extremely low zero drift and excellent long-term working stability.
Fast Response Speed: Optimized internal sensing structure ensures T90 response time less than 150s, realizing rapid response and real-time tracking of ETO gas concentration changes.
Excellent Linearity & Consistency: Stable linear output within the full detection range, small batch difference of product parameters, convenient for standardized calibration and secondary development of detection equipment.
Professional Bias Voltage Matching: Supports 300mV fixed bias voltage drive, matched with conventional toxic gas acquisition circuits, easy for circuit design and system integration.
Wide Environmental Adaptability: Works stably in a wide temperature and humidity range, adapting to complex industrial and medical workshop environmental conditions.
Long Service Life: Industrial-grade durable design, with up to 2-year service life in standard working environment, reducing equipment replacement and maintenance costs.
Product Applications:
Medical Sterilization Industry: Real-time ETO gas leakage monitoring in medical device sterilization workshops, sterilizer peripheral safety detection, and post-sterilization residual gas monitoring.
Pharmaceutical & Biological Industry: Environmental gas safety monitoring in pharmaceutical factories, biological laboratories and sterile production workshops to prevent ETO residual pollution.
Industrial Environmental Monitoring: ETO waste gas emission detection in chemical industry, fine chemical production and ETO processing enterprises, supporting environmental compliance monitoring.
Occupational Health Safety: Personal exposure monitoring and workplace air quality detection for staff engaged in ETO operation, meeting occupational safety and health management standards.
Gas Detection Equipment Manufacturing: Core sensing component for fixed ETO online monitors, portable ethylene oxide detectors and industrial safety alarm devices.
Scientific Research & Experiment: Laboratory gas concentration analysis, ETO gas diffusion research and industrial process gas monitoring experiments.
Product Model
ETO-A1
Detected Gas
Ethylene Oxide (ETO / C2H4O)
Detection Principle
Electrochemical (3-electrode)
Detection Range
0 ~ 100 ppm
Sensitivity
2000 ~ 3200 nA/ppm (@20ppm ETO)
Resolution
< 0.1 ppm (RMS noise equivalent)
Response Time (T90)
≤ 150 s (0 to 20ppm ETO)
Bias Voltage
300 mV
Recommended Load Resistor
10 ~ 47 Ω
Operating Temperature
-30℃ ~ +50℃
Operating Humidity
15%RH ~ 90%RH (Non-condensing)
Operating Pressure
80 ~ 120 kPa
Storage Period
6 months (original package, 3℃~20℃)
Service Life
2 Years (Standard Environment)
Sensor Weight
≤ 6 g
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...