| Payment Terms | L/C, D/A, D/P, T/T, , |
| Supply Ability | 1000 |
| Zero Current (Offset) | < 0.6 %v/v O2 |
| Recommended Load Resistor | 100 ohms |
| Operating Humidity | 5 – 95% RH (non-condensing) |
| Expected Operating Life | >2 years in air |
| Brand Name | SGX |
| Model Number | SGX-4OX |
| Place of Origin | Britain |
View Detail Information
Explore similar products
Storm Pro 2 Portable Lightning Storm Detector Storm Detection and Early Warning
H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
NH3-B1 Ammonia Gas Sensors A-Series Four-Electrode Electrochemical
H2S-B4 Hydrogen Sulfide Sensor High Resolution 4-electrode H2S No Condensation
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, , | Supply Ability | 1000 |
| Zero Current (Offset) | < 0.6 %v/v O2 | Recommended Load Resistor | 100 ohms |
| Operating Humidity | 5 – 95% RH (non-condensing) | Expected Operating Life | >2 years in air |
| Brand Name | SGX | Model Number | SGX-4OX |
| Place of Origin | Britain | ||
| High Light | 4-in-1 oxygen concentration gas sensor ,SGX-4OX 4-in-1 detector | ||
Product Description:
SGX-4OX electrochemical oxygen concentration gas sensor 4-in-1 detector
Features:
IMPORTANT NOTES · All performance is based on conditions at 20°C, 50% RH and 1 atm, using SGX recommended circuitry. · Sensor performance is temperature dependant; please contact SGX for temperature performance other than 20°C. · Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty. · Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
ACID GASES Acid gases such as CO₂ and SO₂ will be absorbed by the electrolyte and tends to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO₂. The SGX4OX sensors are not suitable for continuous operation in concentrations of CO₂ above 25%. CROSS SENSITIVITY DATA Toxic gases at TLV levels will have no cross-sensitivity effect on SGX oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their Oxygen equivalent, but most other commonly occurring gases will have no effect.
Specifications:
| Range | 0 – 25% O2 |
| Output Signal | 70 to 130 µA |
| Typical Baseline Range | -30°C to +50°C |
| Zero Current (Offset) | < 0.6 %v/v O2 |
| Linearity | Linear |
| Response Time (T90) | ﹤15s |
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...