Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time | 3-5workingdays |
Operating Principle | 3-electrode electrochemical |
Measurement Range | 0-40,000 ppm CO |
Maximum Overload | 100,000 ppm CO |
Filter | High capacity filter to remove acid gases from flue stream |
Sensitivity* | 0.007 ± 0.002 μA/ppm |
Resolution | 10 ppm |
Response Time (T90)* | <30 seconds |
Baseline Offset (clean air) | Baseline Offset (clean air) |
Zero Shift (+20°C to +40°C) | <200 ppm equivalent |
Model Number | 3MF |
View Detail Information
Explore similar products
H2S-AH Hydrogen Sulfide Sensor (High Current H2S Sensor) Is Used In Hydrogen
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 3-5workingdays |
Operating Principle | 3-electrode electrochemical | Measurement Range | 0-40,000 ppm CO |
Maximum Overload | 100,000 ppm CO | Filter | High capacity filter to remove acid gases from flue stream |
Sensitivity* | 0.007 ± 0.002 μA/ppm | Resolution | 10 ppm |
Response Time (T90)* | <30 seconds | Baseline Offset (clean air) | Baseline Offset (clean air) |
Zero Shift (+20°C to +40°C) | <200 ppm equivalent | Model Number | 3MF |
High Light | 3MF 3 Series CO Gas Sensor ,200 ppm CO Gas Sensor |
3MF 3 series electrochemical Carbon Monoxide (CO) Gas Sensor Range of accessories available
This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument
in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by
exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out
such tests may jeopardize the safety of people and property.
The cross sensitivity data shown below does not form part of the
product specification and is supplied for guidance only. Values quoted are based on
tests conducted on a small number of sensors and any batch may show significant
variation. For the most accurate measurements, an instrument should be calibrated
using the gas under investigation.
Weight | 22 g |
Orientation | Any |
Operating Temperature Range | -20°C to +50°C |
Recommended Storage Temp | 0°C to 20°C |
Operating Pressure Range | Atmospheric ± 10% |
Operating Humidity Range | Operating Humidity Range |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!