China factories

China factory - ShenzhenYijiajie Electronic Co., Ltd.

ShenzhenYijiajie Electronic Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with
China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with

  1. China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with
  2. China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with
  3. China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with
  4. China 0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with

0-1.0000% 10000PPM 0-25% YJJ OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor with

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 2200
Delivery Time 3 days
Packaging Details boxed
Resolution 0.01ppm
Brand US GE
Measurement accuracy 0.01ppm
Processing customization NO
Brand Name GE
Model Number OX-1 OX-3
Place of Origin USA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 2200
Delivery Time 3 days Packaging Details boxed
Resolution 0.01ppm Brand US GE
Measurement accuracy 0.01ppm Processing customization NO
Brand Name GE Model Number OX-1 OX-3
Place of Origin USA
High Light 0-25% Oxygen Gas Sensor10000PPM Oxygen Gas Sensor0-1.0000% Oxygen Gas Sensor

Product Description:

OX-1 OX-3 Low Oxygen Content Gas Oxygen Sensor Oxygen Battery 0~1.0000%(10000PPM)0-25%

 

Features:

GE oxygen sensor application:

 

1. Purge the sampling system with a non-hazardous low-oxygen gas (e.g., high-purity nitrogen). In normal operation, the gas required to pass into the sensor test head is 500cc/min(1.0SCFH), and the pressure is atmospheric. Continue to pass the gas until installation of the sensor is complete.

 

2. Programming and calibration steps before installation. Then, adjust the 4-20mA analog output and set the measuring range of the measured oxygen to 0-25%O2.

3. Open the sealed box and take out the oxygen sensor. In order to maintain the energy of the oxygen sensor, remove the red patch immediately and proceed to the next step.

4. Adjust the sensor so that its gold electrode is aligned with the elastic contact pin on the base of the transmitter. Press the sensor firmly against the O2X1 transmitter with your hand.

5. Perform air calibration on the new sensor at this time. In the 0-25% oxygen range, proper sensor calibration will result in a 17.4mA current output from the transmitter's 4-20mA analog output.

6. Encapsulate the calibrated sensor in the test head of the transmitter with a knurled nut, adjust the position of the transmitter, and tighten the knurled nut by hand.

7. The analog output reading should begin to drop, reaching a lower oxygen content at equilibrium. At this point, reset the required range.

8. Power the O2X1. After the O2X1 is initialized for about 15 seconds, three LED indicators light up simultaneously for a short time. In order to improve the measurement accuracy of PPM sensors, range gas calibration can now be performed.

 

American GE oxygen sensor

 

Oxygen measurement range :0~1.0000%(10000PPM),0-25%

Accuracy :±0.01%

Resolution :±0.0001%

Linearity :±1%FS

Analog output :4~20mA

GE Oxygen sensor OX- Suitable for GE Panametrics oxy-iq oxygen transmitters and O2X1 oxygen analyzers, is a highly reliable and cost-effective dual-circuit oxygen analyzer with linearized 4 to 20mA outputs. It measures oxygen in a range of 10ppm and a range of seven percent. All ranges are user selectable. This compact transmitter uses advanced sensor technology to accurately measure O2 in a variety of gases, even in hazardous environments.

 

Oxygen sensor GE-OX-3, currently available in China

Oxygen sensor GE-OX-1, currently available in China

Oxygen sensor GE-OX-4, not available in China

Oxygen sensor GE-OX-5, currently available in China

Oxygen sensor GE-OX-2, not available in China

 

Settings:

OX-1 Oxygen Sensor - Trace oxygen sensor for non-acidic gas environments such as nitrogen

OX-2 Oxygen Sensor - Trace oxygen sensor for acidic gas environments such as CO2

OX-3 Oxygen Sensor - Percentage oxygen sensor for non-acidic gas environments such as nitrogen

OX-4 Oxygen Sensor - Percentage oxygen sensor for non-acidic gas environments such as CO2

OX-5 Oxygen Sensor - Micro long-lived oxygen sensor for non-acidic gas environments such as nitrogen

 

Specifications:

Power supply voltage 220V
Specification One
Weight 1.0kg
Measuring range 0-20ppm

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2006

  • Total Annual:

    900000-1000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...

+ Read More

Get in touch with us

  • Reach Us
  • ShenzhenYijiajie Electronic Co., Ltd.
  • Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
  • https://www.oxygengassensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement