Operating Principle | Partial pressure electrochemical |
Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 |
Response Time (T90)* | <15 s (air to 100% O2) |
Baseline Offset* | <200 μV |
Linearity | Linear 0% to 100% O2 |
Model Number | MOX-3 MOX3 AA829-M10 |
View Detail Information
Explore similar products
2FO AA625-180 Air Oxygen Sensor Combustion Efficiency For Fixed Gas Detector
AO2 PTB-18.10 AA428-210 Gas Oxygen Sensor Partial Pressure Electrochemical O2
MOX4 MOX-4 Oxygen Gas Sensor Medical Equipment White ABS AA829-M20 Oxygen
MAX250E R125P03-002 Electrochemical Dissolved Oxygen Sensor For Breathing
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 3-5work days |
Operating Principle | Partial pressure electrochemical | Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 | Response Time (T90)* | <15 s (air to 100% O2) |
Baseline Offset* | <200 μV | Linearity | Linear 0% to 100% O2 |
Model Number | MOX-3 MOX3 AA829-M10 | ||
High Light | MOX3 Oxygen Gas Sensor ,Ventilator Oxygen Gas Sensor ,Anesthesia Machine Oxygen Gas Sensor |
MOX3 Oxygen Sensor
Part Number: AA829-M10
Document Purpose:
The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.
This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).
*Specifications are based on measurements made with cylinder gases using a flow rate of 100 mls min-1 and are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.
Note 1: Use of a regression coefficient shows a best fit straight line better than 0.9995 when measured through the four data points from testing with 100% N2, 21% O2, 60% O2, and 100% O2.
Important Note:
Connection should be made via recommended mating parts only. Soldering to the sensor will damage it and invalidate the warranty.
For further information on the external load resistance and connection to the recommended mating part, please see Operating Principle OP-04 or contact City Technology.
All performance data is based on measurements made with cylinder gases using a flow rate of 100 mls/min. Conditions at 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, contact City Technology.
Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.
Poisoning:
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended Use:
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.
Stabilisation Time:
Allow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturers instructions.
Cleaning and Sterilisation:
In case of contamination the sensor may be cleaned with distilled water and allowed to dry naturally. The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or hydrogen peroxide
Typical Applications | Critical care anesthesia |
Operating Temperature Range | -20°C to +50°C |
Operating Pressure Range | 0.5 Bar to 2.0 Bar |
Operating Humidity Range | 0% to 99% RH non-condensing |
Long-Term Ouput Drift in 100% O2 | < 5% signal loss/year |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!