Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Professional Gas Sensor for Respiratory Anesthesia Machines 8410185","imgUrl":"https:\/\/img.chinax.com\/nimg\/0b\/30\/c4964f91624895df599e928e5674-200x200-1\/professional_gas_sensor_for_respiratory_anesthesia_machines_8410185.jpg","attrs":{"Model Number":" 8410185","Place of Origin":"Germany","Minimum Order Quantity":"1pcs","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/de\/2c3edff3ffc6e6ffe104cf9106a5-200x200-1\/h2s_ah_high_current_hydrogen_sulfide_sensor_for_portable_devices_0_03_ppm_resolution_2_year_service_life.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-AH","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In","imgUrl":"https:\/\/img.chinax.com\/nimg\/3b\/76\/709cbd27e1256f889d1932c83ee4-200x200-1\/nh3_b1_four_electrode_electrochemical_ammonia_sensor_28nh3_sensor_29_is_used_in_ammonia_gas_transmitter.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NH3-B1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor","imgUrl":"https:\/\/img.chinax.com\/nimg\/93\/a5\/26fe289e29911b4d52b464ddf558-200x200-1\/h2s_b4_high_resolution_hydrogen_sulfide_sensor_28h2s_sensor_29_is_used_to_monitor_trace_hydrogen_sulfide_in_air_quality.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-B4","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide","imgUrl":"https:\/\/img.chinax.com\/nimg\/8e\/e9\/481f097eb9ce0c098d1848168c96-200x200-1\/no2_a1_nitrogen_dioxide_sensor_28portable_no2_sensor_29_for_nitrogen_dioxide_portable_monitor.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NO2-A1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection","imgUrl":"https:\/\/img.chinax.com\/nimg\/ad\/40\/82c7966c902dc6957c764eec744c-200x200-1\/no_a1_nitric_oxide_gas_sensor_no_sensor_used_for_automobile_exhaust_detection.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
8410185 Sensors For Respiratory Anesthesia Machines Gas Sensor
Basic Information:
Brand: Drager
Model: 8410185
Product Type: Sensor for breathing anesthesia machines (specifically may be an oxygen sensor or flow sensor, subject to confirmation based on the equipment model)
Applicable Equipment: Compatible with Drager series breathing anesthesia machines (such as Fabius, Primus, etc.)
Origin: Germany (headquarters of Drager, with some components possibly produced in other countries)
Technical Parameters:
Measurement Range:
If it is an oxygen sensor, the measurement range is usually 0%–100% O₂;
If it is a flow sensor, the measurement range shall be determined according to the specific model, generally covering the clinically commonly used respiratory flow range (e.g., 0–150L/min).
Accuracy:
The accuracy of the oxygen sensor is usually ≤±2% FS (full scale);
The accuracy of the flow sensor is ≤±3% of the reading or ±0.5L/min (taking the larger value).
Flow sensor: response time ≤50ms when the airflow changes.
Operating Temperature: 5°C–40°C (in line with the environmental requirements of medical equipment)
Interface Type: Dedicated plug-in interface, compatible with the mainboard or module of Drager equipment
Power Supply Mode: Internal power supply of the equipment (usually DC 5V or 12V)
Product Features:
High Accuracy: Adopts electrochemical or thermal measurement principles to ensure stable and reliable data, meeting the high-precision requirements of clinical anesthesia for gas concentration and flow.
Anti-interference: The sensor design has the ability to resist water vapor and corrosion, reducing errors caused by anesthetic gases, moisture, and other factors in clinical use.
Easy Maintenance: Supports hot-swap replacement without shutdown calibration, and some models have an automatic calibration function (such as zero and span calibration for oxygen sensors).
Safety Certification: Complies with medical equipment certification standards such as CE and ISO 13485, and has passed biocompatibility tests to ensure patient safety.
Application Scenarios:
Breathing Anesthesia Machines: Used for real-time monitoring of parameters such as oxygen concentration and respiratory flow in the inhaled/exhaled gas of patients, providing data support for anesthetic depth control and ventilation management.
Intensive Care Equipment: Some models can be compatible with intensive care ventilators to assist in monitoring gas parameters during mechanical ventilation.
Installation and Maintenance:
Installation Method: Directly insert into the sensor slot of the equipment, fix it with a buckle or screw, and use it after completing calibration according to the instructions.
Replacement Cycle:
Oxygen sensor: It is generally recommended to replace it every 1–2 years (affected by usage frequency and environment);
Flow sensor: There is no clear replacement cycle. If the measurement deviation exceeds the range or a fault code appears, it needs to be replaced in a timely manner.
Calibration Requirements: Standard gases (such as 21% O₂, 100% O₂) are required for calibration when installing for the first time or regularly (such as every 6 months).
Precautions:
No Disassembly: The interior of the sensor is a precision component. Disassembly by non-professionals may cause damage or measurement failure.
Storage Conditions: Store in a dry environment without corrosive gases, at a temperature of 0°C–30°C and a humidity of ≤80%RH.
Compatibility: Only applicable to the specified models of Drager equipment. Do not mix it with equipment of other brands.
Packaging and Certifications:
Packaging: Independent anti-static packaging, including instructions and a calibration certificate.
Certifications: International medical certifications such as CE, ISO 13485, and FDA (if applicable).
Parameter
Details
Brand
Drager
Model
8410185
Product Type
Sensor for breathing anesthesia machines (possibly oxygen/flow
Corrosion-resistant sensor element with anti-moisture design
Calibration Requirement
Standard gas calibration (21% O₂, 100% O₂) required
for first installation and every 6 months
Replacement Cycle
- Oxygen sensor: 1–2 years (usage-dependent) - Flow sensor: As needed (when deviation exceeds range)
Safety Certification
CE, ISO 13485, FDA (if applicable)
Packaging
Anti-static independent package with calibration certificate
Storage Conditions
0°C–30°C, ≤80% RH, dry environment
Compatibility
Exclusive for Drager specified anesthesia machine models
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...