China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for

  1. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
  2. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
  3. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
  4. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
  5. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for
  6. China 25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for

25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified for

  1. MOQ: 1
  2. Price: USD 1000-20000
  3. Get Latest Price
Delivery Time 30Days
Primary Voltage 240Vac
Induced Over-voltage Withstand Test Double frequency / Double Voltage / 60s
Packaging Details Plywood case
Enclosure IP00
Vector Group DYN11/YYN0 or customized
Operating Temperature -15℃~40℃
Storage Temperature -25℃~60℃
Supply Ability 10000set/month
Cooling Method AN Or AF
Insulation Level F/H/C, customized
Insulation Resistance Primary to secondary >500 MΩ; Primary to earth >500 MΩ; Secondary to earth>500 MΩ
Payment Terms T/T
Insulation Class F/H/C Customized
Efficiency compliant with DOE
Ground Resistance 25A<100 mΩ
Winding Material Copper / Aluminum
Enclosures Protection Level IP20 / IP54 / IP56 or NEMA 1 / NEMA 3R / NEMA 3 / NEMA 4 / NEMA 4X, Optional
Withstand Voltage Test Primary to secondary 3.0KV/1min; Primary to earth 3.0KV/1min; Secondary to earth 3.0KV/1min
Transformation Ratio <3%
Impedance Voltage about 4.5%
Secondary Voltage 120Vac
Frequency 50/60Hz
No-load Current <3%
Rated Capacity 25KVA
Temperature Rise ≤100K / ≤115K / ≤125K or customized
Ambient Temperature -15 To +45°C
Certification CE, UL, cUL, TUV
Model Number LL-DG-25kVA
Brand Name Leilang Electric
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 30Days Primary Voltage 240Vac
Induced Over-voltage Withstand Test Double frequency / Double Voltage / 60s Packaging Details Plywood case
Enclosure IP00 Vector Group DYN11/YYN0 or customized
Operating Temperature -15℃~40℃ Storage Temperature -25℃~60℃
Supply Ability 10000set/month Cooling Method AN Or AF
Insulation Level F/H/C, customized Insulation Resistance Primary to secondary >500 MΩ; Primary to earth >500 MΩ; Secondary to earth>500 MΩ
Payment Terms T/T Insulation Class F/H/C Customized
Efficiency compliant with DOE Ground Resistance 25A<100 mΩ
Winding Material Copper / Aluminum Enclosures Protection Level IP20 / IP54 / IP56 or NEMA 1 / NEMA 3R / NEMA 3 / NEMA 4 / NEMA 4X, Optional
Withstand Voltage Test Primary to secondary 3.0KV/1min; Primary to earth 3.0KV/1min; Secondary to earth 3.0KV/1min Transformation Ratio <3%
Impedance Voltage about 4.5% Secondary Voltage 120Vac
Frequency 50/60Hz No-load Current <3%
Rated Capacity 25KVA Temperature Rise ≤100K / ≤115K / ≤125K or customized
Ambient Temperature -15 To +45°C Certification CE, UL, cUL, TUV
Model Number LL-DG-25kVA Brand Name Leilang Electric
Place of Origin China
High Light 25kVA Dry Type Transformer240V/120V Isolation TransformerCE Certified Single Phase Transformer
25kVA Single Phase Dry Type Isolation Transformer 240V/120V CE Certified 50/60Hz for Machinery and Electrical Equipment
Product Overview

This 25kVA Single Phase Dry Type Isolation Transformer is designed for machinery and electrical equipment requiring reliable 240V to 120V voltage conversion. The transformer provides galvanic isolation between the input and output circuits while supplying power to compatible loads. With a dry-type, oil-free construction and 50/60Hz design, it is suitable for a wide range of industrial and commercial installations. CE certification supports applications requiring compliance with relevant European safety requirements.

Key Features
  • 25kVA rated capacity for machinery and electrical equipment
  • 240V primary / 120V secondary voltage configuration
  • Single-phase isolation design with electrical separation between input and output
  • 50Hz or 60Hz operation, depending on the specified design
  • CE certified for applicable project and market requirements
  • Dry-type, oil-free construction for convenient installation
  • Designed for machinery, electrical panels, control equipment, and other compatible loads
  • Custom options available for terminals, enclosure, impedance, and installation conditions
Technical Specifications
Winding Material Enameled copper/aluminum wire, copper/aluminum foil (optional)
Capacity 25KVA (100VA~5000KVA can be customized)
Primary Voltage 240V (Voltage not more than 600V can be customized)
Secondary Voltage 120V (Voltage not more than 600V can be customized)
Frequency 50/60Hz
Vector Group DYN11/YYN0 or customized
Insulation Level F/H/C, customized
Enclosures Protection Level IP20 / IP54 / IP56 or NEMA 1 / NEMA 3R / NEMA 3 / NEMA 4 / NEMA 4X, Optional
Withstand Voltage Test Primary to secondary 3.0KV/1min; Primary to earth 3.0KV/1min; Secondary to earth 3.0KV/1min
Insulation Resistance Primary to secondary >500 MΩ; Primary to earth >500 MΩ; Secondary to earth>500 MΩ
Ground Resistance 25A<100 mΩ
Induced Over-voltage Withstand Test Double frequency / Double Voltage / 60s
Cooling Method AN / AF
Temperature Rise ≤100K / ≤115K / ≤125K or customized
Transformation Ratio <3%
No-load Current <3%
Impedance Voltage about 4.5%
Efficiency compliant with DOE
Operating Temperature -15℃~40℃
Storage Temperature -25℃~60℃
Certificate ISO9001, UL, TUV

Product parameters and images are for general reference only and may not reflect all details of your custom configuration, due to custom builds and minor variations between standard models.

Precise specifications for your order are detailed in the specification table and supporting technical documents (CAD files, dimensional drawings, wiring diagrams, etc.). Specific details may differ from images.

Please review all specifications and technical documents before ordering; do not rely solely on product images.

We offer custom-built units with lead times nearly as fast as prebuilt models--contact us for your specific requirements.

Production Process
Three Phase Isolation Transformer Production Process Diagram
Frequently Asked Questions
What is the difference between voltage conversion and isolation?
This transformer performs both functions: it steps the voltage down from 240V to 120V while electrically isolating the primary and secondary circuits.
Is 25kVA suitable for my equipment?
The transformer capacity should be selected based on the actual load, starting current, duty cycle, and possible future expansion. Providing your equipment specifications allows the transformer to be properly matched.
Can it be installed inside a machine or electrical cabinet?
Yes, provided that sufficient ventilation, clearance, protection, and installation conditions are considered. Enclosure and mounting options can also be customized for the application.
Can the transformer be customized?
Yes. We can customize the voltage ratio, frequency, terminals, enclosure, insulation system, protection level, and other parameters based on your machinery or electrical system requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2007

  • Total Annual:

    100000000-100000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Verified Supplier

.gtr-container-a7b3c9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-a7b3c9... .gtr-container-a7b3c9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-a7b3c9...

+ Read More

Get in touch with us

  • Reach Us
  • Leilang Electric Group CO.,LTD
  • No. 2200, Zhude Road, Jiading District, Shanghai, China
  • https://www.padmount-transformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement