China GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration
China GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration

  1. China GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration
  2. China GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration
  3. China GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration

GOLDWAY G60 Mainboard P/N 453564288752 for Electronic Device Integration

  1. MOQ: 1
  2. Price: Negotiation, pls contact me
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 10
Delivery Time Within 1-2 working days after the payment was confirmed
Packaging Details Carton box
BRAND GOLDWAY
MODEL G60
PN 453564288752
CONDITION EXCELLENT
WARRANTY 90 DAYS
PRICE NEGOTIABLE
Brand Name goldway
Model Number G60
Place of Origin ORIGINAL

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 10
Delivery Time Within 1-2 working days after the payment was confirmed Packaging Details Carton box
BRAND GOLDWAY MODEL G60
PN 453564288752 CONDITION EXCELLENT
WARRANTY 90 DAYS PRICE NEGOTIABLE
Brand Name goldway Model Number G60
Place of Origin ORIGINAL
High Light GOLDWAY G60 Mainboard453564288752 Mainboard

 GOLDWAY G60 Mainboard P/N 453564288752

 

1. Core Identification & Basic Info

 
  • Model:  G60 Mainboard (Philip Goldway)
  • Part Number (P/N): 453564288752 (Original Mainboard)
  • Category: Medical-Grade Patient Monitor Main Circuit Board
  • Compatibility:  GOLDWAY G60 Modular Bedside Patient Monitor
  • Dimensions: Approx. 14 × 10 × 8 cm
  • Net Weight: 0.65 kg
  • Board Type: Multi-layer PCB, Modular Expansion Design
 

2. Electrical & Power Specifications

 
  • Power Input Interface: Integrated with Host Power Module, Input: 100–240 VAC, 50/60 Hz, 1.5 A
  • Onboard Power Output: Stable DC Output for Modules & Peripherals (12V, 5V, 3.3V)
  • Power Management: Over-voltage, Over-current, Short-circuit & ESD Protection
  • Standby Power Consumption: < 5 W
 

3. Communication & Expansion Interfaces

 
  • Network Interface: 1× Gigabit Ethernet (LAN) for HL7 Protocol, Central Monitoring System (UT4800) & Bed-to-Bed Networking
  • Peripheral Interfaces: 2× USB 2.0, 1× VGA (External Display Output), 1× Nurse Call Port, 1× RS232 Serial Port
  • Module Expansion Slots: 5× Dedicated Modular Slots for Plug-and-Play Parameter Modules (ECG/SpO₂/NIBP/IBP/etCO₂/12-Lead ECG/CO/Multigas)
  • Alarm Interface: Integrated Visual/Audible Alarm Control Circuit
 

4. Data Storage & Processing

 
  • Onboard Memory: 8 GB Flash Storage + 2 GB DDR3 RAM
  • Trend Data Storage: Up to 2400 Hours of Multi-Parameter Trend Data
  • Waveform Storage: 240 Minutes Full-Disclosure ECG Waveform Recording
  • Alarm Event Log: Stores up to 500 Alarm Events & User Operation Logs
  • Real-Time Processing: High-Speed MCU for ECG/Resp/SpO₂/NIBP Signal Processing & Analysis
 

5. Supported Monitoring Parameters & Performance

 
  • Standard Parameters Supported:
    • ECG (3/5-Lead, 12-Lead Optional): ST Segment Analysis, Arrhythmia Detection, Pacemaker Recognition, HR Range 15–300 bpm, Accuracy ±1% or ±2 bpm
    • SpO₂ (Philip FAST-SpO₂): Range 0–100%, Accuracy ±2% (70–100% range), PR 20–250 bpm
    • NIBP: Oscillometric Method, Accuracy ±5 mmHg (±0.7 kPa), Adult/Pediatric/Neonatal Modes
    • RESP: Impedance Method, RR 5–120 bpm, Accuracy ±2 bpm
    • Dual-Channel TEMP: Range 0–50°C, Accuracy ±0.1°C
     
  • Optional Extended Parameters: Dual IBP, etCO₂ (Microstream), Cardiac Output (CO), Multigas Monitoring
 

6. Compliance & Safety Standards

 
  • Safety Certification: IEC 60601-1:2005+AMD1:2012, IEC 60601-1-2:2014
  • Quality Management: ISO 9001, ISO 13485, CE (MDR 2017/745), FDA Compliant
  • EMC Compliance: IEC 60601-1-2:2014 (Electromagnetic Immunity & Emission)
  • Environmental Rating: IPX1 (Drip-Proof), Operating Temp 10–35°C, Storage Temp -20–60°C
 

7. Maintenance & Service Notes

 
  • Warranty: 90 Days for New/Original Unit
  • Replacement Requirement: Must Match P/N 453564288752 for Full Compatibility
  • Calibration: Re-calibrate All Parameter Modules After Mainboard Replacement
  • ESD Protection: Strict Anti-ESD Handling Required During Installation/Repair
  • Storage: Dry, Dust-Free Environment (Relative Humidity 30–75%)

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Trading Company,Seller,Other

  • Year Established:

    2023

  • Total Annual:

    10000-50000

  • Employee Number:

    1~50

  • Ecer Certification:

    Verified Supplier

STAR 9 BIOLOGICAL TECHNOLOGY CO.,LTD. is a medical maintenance third-party service company committed to "focus on monitoring and maintenance, complete accessories". Has been in line with the "integrity management, professional service" maintenance service concept, service in t... STAR 9 BIOLOGICAL TECHNOLOGY CO.,LTD. is a medical maintenance third-party service company committed to "focus on monitoring and maintenance, complete accessories". Has been in line with the "integrity management, professional service" maintenance service concept, service in t...

+ Read More

Get in touch with us

  • Reach Us
  • STAR 9 BIOLOGICAL TECHNOLOGY CO.,LTD.
  • ROOM 1199 , NO 119 JINSHAZHOU ROAD JINSHA STREET BAIYUN AREA GUANGZHOU
  • https://www.patientmonitor-parts.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement