China factories

Chat Now Send Email
China factory - Guangzhou YIGU Medical Equipment Service Co.,Ltd

Guangzhou YIGU Medical Equipment Service Co.,Ltd

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer
China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer

  1. China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer
  2. China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer
  3. China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer
  4. China PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer

PN 453564206131 Defibrillator Machine Parts HR XL+ Defibrillator Printer

  1. MOQ: 1/PCS
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms TT/, Western Union/paypal
Delivery Time within 1 working day after payment confirmed
Packaging Details Carton Box
Condition Excellet
Model HR XL+ Defibrillator Printer
REF 453564206131
Feature Defibrillator Machine Parts
Origin US
Description Medical Parts
Model Number HR XL+

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms TT/, Western Union/paypal Delivery Time within 1 working day after payment confirmed
Packaging Details Carton Box Condition Excellet
Model HR XL+ Defibrillator Printer REF 453564206131
Feature Defibrillator Machine Parts Origin US
Description Medical Parts Model Number HR XL+
High Light 453564206131 Defibrillator Machine PartsHR XL Defibrillator Machine Parts

HR XL+ Defibrillator Printer PN 453564206131 Defibrillator Machine Parts

 

 

Description

 

Payment:TT and Paypal

Shipment:DHL,EMS and FedEx

Tracking Number:Within two days of shipment

Warranty Time:90 Days

 

 

Note

 

We are also selling power supply, printer, high voltage board, blood oxygen board, ECG board, keypress board, mainboard, NIBP board (pump) of mindray PM series monitor.

Let us know your kind enquiry. Do not hesitate to contact with us for futher information.

 

 

Common Faults Repair

  • 1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
  • 3. The module can’t be connected. 4. Automatically disconnect.
  • 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
  • 7. Unable to contact. 8. Error reporting MMS disconnected.
  • 9. False alarm MMS pull out. 10. Can’t load out.
  • 11. ECG malfunctions. 12. ECG equipment out of order.
  • 13. Software upgrades. 14. NIBP fails to inflate.
  • 15. IBP equipment faults. 16. M3012A module can’t be detected.
  • 17. Automatically restart. 18. The encoder can’t work.
  • 19. Blue screen appears after startup. 20. No ECG signal.
  • 21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
  • 23. Report CO2 plugging. 24. MMSL developing module faults.
  • 25. M3015A / M3001A module faults. 26. No power display light.
  • 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
  • 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
  • 31. The key plate is out of order. 32. Encoder failure.
  • 33. Can’t inflate. 34. NIBP equipment faults.
  • 35. SP O2 and ECG equipment fault. 36. Unable to charge.
  • 37. The touch screen can’t work. 38. The screen shows double image.
  • 39. Error code 1000. Error code 20004. 40. No alarm sounds.

 

 

Business Scopes
Repairing Services
Monitor, ECG, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor and spare parts
Sell and Replace Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
Service Brands


GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, , TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2011

  • Total Annual:

    1000000-3000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medic... Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medic...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou YIGU Medical Equipment Service Co.,Ltd
  • Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China
  • https://www.patientmonitor-repair.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement